scholarly journals X-ray Scatter Imaging of Hepatocellular Carcinoma in a Mouse Model Using Nanoparticle Contrast Agents

2015 ◽  
Vol 5 (1) ◽  
Author(s):  
Danielle Rand ◽  
Zoltan Derdak ◽  
Rolf Carlson ◽  
Jack R. Wands ◽  
Christoph Rose-Petruck

Abstract Hepatocellular carcinoma (HCC) is one of the most common malignant tumors worldwide and is almost uniformly fatal. Current methods of detection include ultrasound examination and imaging by CT scan or MRI; however, these techniques are problematic in terms of sensitivity and specificity and the detection of early tumors (<1 cm diameter) has proven elusive. Better, more specific and more sensitive detection methods are therefore urgently needed. Here we discuss the application of a newly developed x-ray imaging technique called Spatial Frequency Heterodyne Imaging (SFHI) for the early detection of HCC. SFHI uses x-rays scattered by an object to form an image and is more sensitive than conventional absorption-based x-radiography. We show that tissues labeled in vivo with gold nanoparticle contrast agents can be detected using SFHI. We also demonstrate that directed targeting and SFHI of HCC tumors in a mouse model is possible through the use of HCC-specific antibodies. The enhanced sensitivity of SFHI relative to currently available techniques enables the x-ray imaging of tumors that are just a few millimeters in diameter and substantially reduces the amount of nanoparticle contrast agent required for intravenous injection relative to absorption-based x-ray imaging.

2018 ◽  
Vol 619 ◽  
pp. A16
Author(s):  
C. Vignali ◽  
P. Severgnini ◽  
E. Piconcelli ◽  
G. Lanzuisi ◽  
R. Gilli ◽  
...  

Context. The search for heavily obscured active galactic nuclei has been revitalized in the last five years by NuSTAR, which has provided a good census and spectral characterization of a population of such objects, mostly at low redshift, thanks to its enhanced sensitivity above 10 keV compared to previous X-ray facilities, and its hard X-ray imaging capabilities. Aims. We aim at demonstrating how NGC 2785, a local (z = 0.009) star-forming galaxy, is responsible, in virtue of its heavily obscured active nucleus, for significant contamination in the non-imaging BeppoSAX/PDS data of the relatively nearby (≈17′) quasar IRAS 09104+4109 (z = 0.44), which was originally mis-classified as Compton thick. Methods. We analyzed ≈71 ks NuSTAR data of NGC 2785 using the MYTorus model and provided a physical description of the X-ray properties of the source for the first time. Results. We found that NGC 2785 hosts a heavily obscured (NH ≈ 3 × 1024 cm−2) nucleus. The intrinsic X-ray luminosity of the source, once corrected for the measured obscuration (L2−10keV ≈ 1042 erg s−1), is consistent within a factor of a few with predictions based on the source mid-infrared flux using widely adopted correlations from the literature. Conclusions. Based on NuSTAR data and previous indications from the Neil Gehrels Swift Observatory (BAT instrument), we confirm that NGC 2785, because of its hard X-ray emission and spectral shape, was responsible for at least one third of the 20–100 keV emission observed using the PDS instrument onboard BeppoSAX, originally completely associated with IRAS 09104+4109. Such emission led to the erroneous classification of this source as a Compton-thick quasar, while it is now recognized as Compton thin.


2016 ◽  
Vol 6 (1) ◽  
Author(s):  
Danielle Rand ◽  
Zoltan Derdak ◽  
Rolf Carlson ◽  
Jack R. Wands ◽  
Christoph Rose-Petruck

2021 ◽  
Vol 2021 ◽  
pp. 1-15
Author(s):  
José Carlos De La Vega ◽  
Pedro Luis Esquinas ◽  
Jovan Kaur Gill ◽  
Selin Jessa ◽  
Bradford Gill ◽  
...  

Purpose. The majority of X-ray contrast agents (XCA) are made with iodine, but iodine-based XCA (I-XCA) exhibit low contrast in high kVp X-rays due to iodine’s low atomic number (Z = 53) and K-edge (33.1 keV). While rhenium is a transition metal with a high atomic number (Z = 75) and K-edge (71.7 keV), the utilization of rhenium-based XCA (Re-XCA) in X-ray imaging techniques has not been studied in depth. Our study had two objectives: (1) to compare both the image quality and the absorbed dose of I- and Re-XCA and (2) to prepare and image a rhenium-doped scaffold. Procedures. I- and Re-XCA were prepared and imaged from 50 to 120 kVp by Micro-computed tomography (µCT) and digital radiography and from 120 to 220 kVp by planar X-ray imaging. The scans were repeated using 0.1 to 1.6 mm thick copper filters to harden the X-ray beam. A rhenium-doped scaffold was prepared via electrospinning, used to coat catheters, and imaged at 90 kVp by µCT. Results. I-XCA have a greater contrast-to-noise ratio (CNR) at 50 and 80 kVp, but Re-XCA have a greater CNR at >120 kVp. The difference in CNR is increased as the thickness of the copper filters is increased. For instance, the percent CNR improvement of rhenium over iodine is 14.2% with a 0.6 mm thick copper filter, but it is 59.1% with a 1.6 mm thick copper filter, as shown at 120 kVp by µCT. Upon coating them with a rhenium-doped scaffold, the catheters became radiopaque. Conclusions. Using Monte Carlo simulations, we showed that it is possible to reduce the absorbed dose of high kVp X-rays while allowing the acquisition of high-quality images. Furthermore, radiopaque catheters have the potential of enhancing the contrast during catheterizations and helping physicians to place catheters inside patients more rapidly and precisely.


Author(s):  
M.G. Baldini ◽  
S. Morinaga ◽  
D. Minasian ◽  
R. Feder ◽  
D. Sayre ◽  
...  

Contact X-ray imaging is presently developing as an important imaging technique in cell biology. Our recent studies on human platelets have demonstrated that the cytoskeleton of these cells contains photondense structures which can preferentially be imaged by soft X-ray imaging. Our present research has dealt with platelet activation, i.e., the complex phenomena which precede platelet appregation and are associated with profound changes in platelet cytoskeleton. Human platelets suspended in plasma were used. Whole cell mounts were fixed and dehydrated, then exposed to a stationary source of soft X-rays as previously described. Developed replicas and respective grids were studied by scanning electron microscopy (SEM).


Sensors ◽  
2021 ◽  
Vol 21 (13) ◽  
pp. 4554
Author(s):  
Ralph-Alexandru Erdelyi ◽  
Virgil-Florin Duma ◽  
Cosmin Sinescu ◽  
George Mihai Dobre ◽  
Adrian Bradu ◽  
...  

The most common imaging technique for dental diagnoses and treatment monitoring is X-ray imaging, which evolved from the first intraoral radiographs to high-quality three-dimensional (3D) Cone Beam Computed Tomography (CBCT). Other imaging techniques have shown potential, such as Optical Coherence Tomography (OCT). We have recently reported on the boundaries of these two types of techniques, regarding. the dental fields where each one is more appropriate or where they should be both used. The aim of the present study is to explore the unique capabilities of the OCT technique to optimize X-ray units imaging (i.e., in terms of image resolution, radiation dose, or contrast). Two types of commercially available and widely used X-ray units are considered. To adjust their parameters, a protocol is developed to employ OCT images of dental conditions that are documented on high (i.e., less than 10 μm) resolution OCT images (both B-scans/cross sections and 3D reconstructions) but are hardly identified on the 200 to 75 μm resolution panoramic or CBCT radiographs. The optimized calibration of the X-ray unit includes choosing appropriate values for the anode voltage and current intensity of the X-ray tube, as well as the patient’s positioning, in order to reach the highest possible X-rays resolution at a radiation dose that is safe for the patient. The optimization protocol is developed in vitro on OCT images of extracted teeth and is further applied in vivo for each type of dental investigation. Optimized radiographic results are compared with un-optimized previously performed radiographs. Also, we show that OCT can permit a rigorous comparison between two (types of) X-ray units. In conclusion, high-quality dental images are possible using low radiation doses if an optimized protocol, developed using OCT, is applied for each type of dental investigation. Also, there are situations when the X-ray technology has drawbacks for dental diagnosis or treatment assessment. In such situations, OCT proves capable to provide qualitative images.


2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Łukasz Kiraga ◽  
Paulina Kucharzewska ◽  
Damian Strzemecki ◽  
Tomasz P. Rygiel ◽  
Magdalena Król

Abstract In vivo tracking of administered cells chosen for specific disease treatment may be conducted by diagnostic imaging techniques preceded by cell labeling with special contrast agents. The most commonly used agents are those with radioactive properties, however their use in research is often impossible. This review paper focuses on the essential aspect of cell tracking with the exclusion of radioisotope tracers, therefore we compare application of different types of non-radioactive contrast agents (cell tracers), methods of cell labeling and application of various techniques for cell tracking, which are commonly used in preclinical or clinical studies. We discuss diagnostic imaging methods belonging to three groups: (1) Contrast-enhanced X-ray imaging, (2) Magnetic resonance imaging, and (3) Optical imaging. In addition, we present some interesting data from our own research on tracking immune cell with the use of discussed methods. Finally, we introduce an algorithm which may be useful for researchers planning leukocyte targeting studies, which may help to choose the appropriate cell type, contrast agent and diagnostic technique for particular disease study.


1943 ◽  
Vol 78 (4) ◽  
pp. 285-304 ◽  
Author(s):  
William F. Friedewald ◽  
Rubert S. Anderson

The virus-induced papillomas of cottontail as well as domestic rabbits regress completely within a few weeks when exposed to 5,000 r of x-ray irradiation. The x-rays do not immediately kill the papilloma cells, but lead to death by inhibiting cellular division and producing pathological changes in the cells which then continue to differentiate. The virus associated with the growths, however, not only persists in undiminished amount during regression, but often an increased yield of it can be obtained on extraction. The fibroma virus in crude extracts or in vivo is inactivated by far less irradiation than the papilloma virus. 10,000 r destroys 90 per cent or more of the infectivity of the fibroma virus, whereas at least 100,000 r is required to inactivate 50 per cent of the papilloma virus in extracts containing about the same amount of protein. No variant of the papilloma virus or fibroma virus has been encountered as a result of the irradiation.


2021 ◽  
Author(s):  
Julius Muchui Thambura ◽  
Jeanette G.E du Plessis ◽  
Cheryl M E McCrindle ◽  
Tanita Cronje

Abstract Introduction Anecdotal evidence suggests that medical professionals in trauma units are requesting additional regional images using conventional x-ray systems, even after trauma patients have undergone full-body Lodox scans. Patients are then exposed to additional radiation, additional waiting times and an increased medical bill. This study aimed at investigating the extent to which Lodox systems were used in trauma units (n=28) in South Africa. Method In this descriptive cross-sectional study, the researcher invited one radiographer from the 28 hospitals in South Africa that use Lodox systems. Radiographers who were most experienced in using the Lodox system completed an online questionnaire. Results Twenty (71.43% n=20) out of twenty-eight radiographers responded. Most hospitals (90%, n=18) were referring patients for additional conventional x-ray images. Radiographers indicated that conventional x-rays were requested for the chest (27.80%, 10/36), the abdomen (16.67%, 6/36), the spine (13.89%, 5/36) and the extremities and skull (19.44%, 7/36). Additionally, radiographers reported using Lodox to perform procedures and examinations usually performed on conventional x-ray systems when conventional x-ray systems were not operational. Conclusion Currently, it is not clear if the use of conventional x-ray imaging following Lodox is necessary, but the results suggest that the practice is commonplace, with healthcare workers in most hospitals (90%, n=18) requesting additional x-ray imaging. The researcher thus recommends that an imaging protocol for Lodox imaging systems should be developed to guide the referral of the patients for further imaging.


2015 ◽  
Vol 60 (2) ◽  
pp. 769-784 ◽  
Author(s):  
Danielle Rand ◽  
Edward G Walsh ◽  
Zoltan Derdak ◽  
Jack R Wands ◽  
Christoph Rose-Petruck

2021 ◽  
Author(s):  
Eric Da Silva

A hydroxyaptite [HAp; Ca5(PO4)3OH] phantom material was developed with the goal of improving the calibration protocol of the 125I-induced in vivo X-ray fluorescence (IVXRF) system of bone strontium quantification with further application to other IVXRF bone metal quantification systems, particulary those associated with bone lead quantification. It was found that calcium can be prepared pure of inherent contamination from strontium (and other elements) through a hydroxide precipitation producing pure Ca(OH)2, thereby, allowing for the production of a blank phantom which has not been available previously. The pure Ca(OH)2 can then be used for the preparation of pure CaHPO4 ⋅ 2H2O. A solid state pure HAp phantom can then be prepared by reaction of Ca(OH)2 and CaHPO4 ⋅ 2H2O mixed as to produce a Ca/P mole ratio of 1.67, that in HAp and the mineral phase of bone, in the presence of a setting solution prepared as to raise the total phosphate concentration of the solution by increasing the solubility CaHPO4 ⋅ 2H2O and thereby precipitating HAp. The procedure can only be used to prepare phantoms in which doping with the analyte does not disturb the Ca/P ratio substantially. In cases in which phantoms are to be prepared with high concentrations of strontium, the cement mixture can be modified as to introduce strontium in the form of Sr(OH)2 ⋅ 8H2O as to maintain a (Ca + Sr)/P ratio of 1.67. It was found by both X-ray diffraction spectrometry and Raman spectroscopy studies that strontium substitutes for calcium as in bone when preparing phantoms by this route. The necessity for the blank bone phantoms was assessed through the first blank bone phantom measurement and Monte Carlo simulations. It was found that for the 125I-induced IVXRF system of bone strontium quantification, the source, 125I brachytherapy seeds may be contributing coherently and incoherently scattered zirconium X-rays to the measured spectra, thereby requiring the use of the blank bone phantom as a means of improving the overall quantification methodology. Monte Carlo simulations were employed to evaluate any improvement by the introduction of HAp phantoms into the coherent normalization-based calibration procedure. It was found that HAp phantoms remove the need for a coherent conversion factor (CCF) thereby potentially increasing accuracy of the quantification. Further, it was found that in order for soft tissue attenuation corrections to be possible using spectroscopic information alone, HAp along with a suitable soft tissue surrogate material need to be employed. The HAp phantom material was used for the evaluations of portable X-ray analyzer systems for their potential for IVXRF quantification of lead and strontium with a focus on a comparison between tungsten, silver and rhodium target systems. Silver and rhodium target X-ray tube systems were found to be comparable for this quantification.


Sign in / Sign up

Export Citation Format

Share Document