A low cost and rapid analytical technique for direct spectrophotometric determination of chromium in V–Cr–Ti alloys without a chromogenic agent

2017 ◽  
Vol 9 (30) ◽  
pp. 4471-4475 ◽  
Author(s):  
L. F. Tian ◽  
D. S. Zou ◽  
Y. C. Dai ◽  
L. L. Wang ◽  
W. Gao

A simple, rapid and accurate spectrophotometric method was developed for the determination of chromium in V–Cr–Ti ternary alloy without any prior separation and chromogenic agent.

2016 ◽  
Vol 8 (33) ◽  
pp. 6284-6292
Author(s):  
Nuket Kartal Temel ◽  
Ramazan Gürkan

A simple and low-cost catalytic spectrophotometric method using sodium dodecyl sulfate (SDS) as a sensitivity-improving surfactant to detect low levels of Mo(vi) in beverage matrices was developed.


2017 ◽  
Vol 1 (2) ◽  
pp. 24-29
Author(s):  
Fábio De Souza Barbosa ◽  
Vanise Coty Rodrigues ◽  
Nadia Maria Volpato ◽  
Elfrides E. S. Schapoval ◽  
Martin Steppe ◽  
...  

UV spectrophotometry is an analytical technique used routinely for qualitative and quantitative assay due the low cost and reliability during analysis. In this work, it was validated a quantitative UV method for determination of agomelatine in coated tablets. The parameters specificity, linearity, precision, accuracy and robustness were evaluated according to official guidelines. Methanol was selected as solvent and the maximum wavelength for drug analysis was 230 nm. The purposed assay showed to be specific and the linearity was proved in a range of 0.5 - 2.5 µg/mL. The RSD values obtained during precision assay (inter-day RSD = 1.75%) indicated the method reproducibility, and the accuracy testing showed good results from recovery test. Robustness assay was complementary and showed that the purposed method is adequate for drug quantitation in commercial samples, being a reliable alternative to chromatographic assay.


1976 ◽  
Vol 59 (4) ◽  
pp. 807-810
Author(s):  
Jeffrey C Hamm

Abstract The USP analysis for procainamide HCl is titrimetric and relatively nonspecific, capsule and tablet dyes may interfere, and the method is not applicable to coated tablets. In the spectrophotofluorometric method the sample deteriorates when exposed to a xenon source. In the ultraviolet spectrophotometric method reported here, the sample is dispersed in acid medium, possible interferences are extracted in chloroform, base is added, procainamide is extracted in chloroform, the residue is dissolved in sodium hydroxide, and the compound is measured by absorption at 272 nm and comparison with a standard. Recoveries of standards added to capsule, tablet, and injection composites ranged from 99.3 to 102%. Twelve collaborators reported duplicate assay results for all 3 dosage forms with per cent standard deviations for 5 samples ranging from 1.01 to 1.27%. The method has been adopted as official first action.


2010 ◽  
Vol 9 (2) ◽  
pp. 254-260
Author(s):  
Choirul Amri ◽  
Dwi Siswanta ◽  
Mudasir Mudasir

A study of extraction-spectrophotometric method for the determination of trace nitrite as 4-(4-nitrobenzenazo)-1-aminonaphthalene complex using n-amylalcohol and chloroform as organic solvents has been done. Results of the study showed that extraction-spectrophotometric determination of nitrite using n-amylalcohol or chloroform was very sensitive and had low limit of detection. Extraction-spectrophotometric method of nitrite using n-amylalcohol gave range of linear concentration 0.000-0.054 mg/L NO2--N, detection limit of 2.09x10-4 mg/L NO2--N, and sensitivity of 34.514 ± 0.398 absorbance unit per mg/L of NO2--N. Meanwhile, extraction-spectrophotometric of nitrite using chloroform had range of linear concentration of 0.000-0.100 mg/L NO2--N, detection limit of 8.99x10-4 mg/L NO2--N, and sensitivity of 18.353 ± 0.456 absorbance unit per mg/L NO2--N.   Keywords: Nitrite Trace, 4-(4-Nitrobenzenazo)-1-Aminonaphthalene, Extraction-Spectrophotometry


2021 ◽  
Vol 9 (2) ◽  
pp. 64-71
Author(s):  
Mykola Blazheyevskiy ◽  
◽  
Valeriy Moroz ◽  
Olena Mozgova ◽  
◽  
...  

The oxidative derivatization method using potassium hydrogenperoxomonosulfate for the indirect spectrophotometric determination of Fluphenazine hydrochloride is presented. Potassium hydrogenperoxomonosulfate is introduced as a derivatizing agent for Fluphenazine hydrochloride, yielding the sulfoxide. This reaction product was successfully used for the spectrophotometric determination of the Fluphenazine hydrochloride. The UV spectroscopic detection of the sulfoxide proved to be a more robust and sensitive method. The elaborated method allowed the determination of Fluphenazine hydrochloride in the concentration range of 0.2-30 µg mL-1. The molar absorptivity at 349 nm is 5.6×103 (dm3cm-1mol-1). The limit of quantification, LOQ (10S) is 0.24 µg/mL. A new spectrophotometric technique was developed and the possibility of quantitative determination of Fluphenazine hydrochloride in tablets 5.0 mg was demonstrated. The present method is precise, accurate and excipients did not interfere. RSD for Fluphenazine Hydrochloride 5.0 mg tablets was 1.37 %.


2011 ◽  
Vol 8 (1) ◽  
pp. 110-117 ◽  
Author(s):  
Baghdad Science Journal

A simple, accurate and sensitive spectrophotometric method for the determinaion of epinephrine is described . The method is based on the coordination of Pr (III) with epinephrine at pH 6. Absorbance of the resulting orange yellow complex is measured at 482 nm . A graph of absorbance versus concentrations shows that beer 's low is obeyed over the concentration range (1-50)mg.ml-1 of epinephrine with molar absorpitivity of ( 2.180x103 L.mol-1.cm-1 ), a sandell sensitivity of (0.084 mg.cm-2 ), a relative error of (-2.83%) , a corrolation coffecient (r= 0.9989) and recovery % ( 97.03 ± 0.75 ) depending on the concentration.This method is applied to analyse EP in several commercially available pharmaceutical preparations using direct methods .All statistical calculations are implemented via a Minitab software version 11.


1963 ◽  
Vol 9 (3) ◽  
pp. 283-295 ◽  
Author(s):  
Roman L Patrick ◽  
Ralph E Thiers

Abstract A rapid and sensitive direct spectrophotometric method for the determination of cerebrospinal fluid protein which uses as little as 0.1 ml. of sample has been described. The result is not affected by the ratio of albumin to globulin in the sample. Interfering substances are removed prior to spectrophotometric measurement with an automatic separation chamber employing the principle of gel filtration. Slight alterations of the procedure described for the measurement of protein enable one to obtain the nonprotein moiety for study or to measure proteins in other biologic fluids.


1987 ◽  
Vol 70 (3) ◽  
pp. 560-565
Author(s):  
Elaine A Bunch

Abstract A previously reported visible spectrophotometric method for the analysis of aminacrine hydrochloride in creams, jellies, and suppositories was studied collaboratively by 8 laboratories. Aminacrine hydrochloride was extracted into acidic ethanol and its visible spectrum recorded. The amount present was calculated by determining the net absorbance between the absorbance maximum at about 402 nm and one-half the sum of the absorbance of the minima at about 389 and 412 nm. Each collaborator received 4 creams (0.2%), 1 jel (0.2%), 1 molded suppository (6 mg/3.198 g), and 2 gelatin-encapsulated suppository samples (12 mg/6.661 g and 14 mg/6.863 g). The cream samples included blind duplicates prepared to contain 0.212% aminacrine hydrochloride, 15% sulfanilamide, and 2% allantoin. Mean recovery for the authentic cream was 104.7% with a coefficient of variation (CV) of 9.22%. The commercial products contained these respective amounts (CVs): creams, 100.0% (2.48%) and 101.5% (2.16%); jel, 118.0% (9.58%); molded suppository, 102.7% (1.88%); and gelatin encapsulated suppositories, 93.1% (1.0%) and 94.3% (1.60%). Standard aminacrine hydrochloride provided for the study was 99.6% pure by nonaqueous titration. Thin layer chromatographic identification of aminacrine hydrochloride was also tested collaboratively. The method was not adopted by AOAC.


1990 ◽  
Vol 73 (2) ◽  
pp. 257-259 ◽  
Author(s):  
Ivan Chang-Yen ◽  
Keshore Bidasee

Abstract An improved visible spectrophotometric method has been developed for cyclopiazonic acid in poultry feed and corn. The method Is based on the reaction of cyclopiazonic acid with Ehrlich reagent and detection at 580 nm. Reaction conditions were optimized with respect to reaction and measurement times and acid and Ehrlich reagent concentrations. Calibration curves were linear from 1 to 20 μg cyclopiazonic acid in 3 mL Ehrlich reagent, with a lower detection limit of 0.08 mg/kg for 50 g samples of poultry feed and corn. Recoveries from 50 g samples of poultry feed spiked with cyclopiazonic ranging from 0.16 to 1.20 mg/kg averaged 93.8%. Moldy corn and poultry feed samples analyzed by this method contained between 1 and 4 mg/kg cyclopiazonic acid.


2017 ◽  
Vol 105 (12) ◽  
Author(s):  
O. A. Elhefnawy

AbstractA spectrophotometric method was developed for U(VI) and Th(IV) determination in acidic medium by using proposed optical sensor. This sensor is base on the complexation reaction of the ionophore midodrine hydrochloride (


Sign in / Sign up

Export Citation Format

Share Document