A hydrogen evolution catalyst lowering energy consumption in aluminum anodization

Author(s):  
Xiang Li ◽  
Xianfeng Du ◽  
Lilong Xiong ◽  
Shan Huang

Aluminum anodization process requires a lot of electric energy for ions migration in barrier-type oxide film, in which the electrode polarization leads the massive energy consumption. The cathodes are considered...

Author(s):  
André Gadelha de Oliveira ◽  
Jefferson Pereira Ribeiro ◽  
Eliezer Fares Abdala Neto ◽  
Ari Clecius Alves de Lima ◽  
Álvaro Amanajás Amazonas ◽  
...  

Abstract The use of the pulsed current can be an alternative to decrease the electrode polarization, as well as achieving lower energy consumption. This study investigated the electrocoagulation through pulsed current for the removal of natural organic matter from water. The experiments were carried out using Box–Behnken factorial design with the response surface methodology for the design of experiments, modeling and interpreting of the results. The electrocoagulation cell consisted of an acrylic reactor with 4 L capacity with four electrodes of aluminum, in parallel connection mode. The experimental independent variables studied were: current density (5.5 to 44.5 A m−2), electrodes spacing (2 to 7.6 mm), stirring rate (200 to 1,000 rpm), frequency (500 to 5,000 Hz), humic acid concentration (5 to 20 mg L−1) and NaCl (100 to 300 mg L−1) as supporting electrolyte, evaluating the residual apparent color (RAC) and electric energy consumption (EEC). The pH of the solution increased during the experiments, reaching basic values. The response surface regression procedure was employed to fit the second-order polynomial, and the model fitted well to the obtained values, reaching R2 0.9995 (RAC) and R2 0.9989 (EEC). The lowest RAC was 11.8 Hazen units (96.2% color removal), where the EEC was 0.393 kWh m−3.


2012 ◽  
Vol 7 (3) ◽  
pp. 23-32 ◽  
Author(s):  
Miloslav Bagoňa ◽  
Dušan Katunský ◽  
Martin Lopušniak ◽  
Marián Vertaľ

1994 ◽  
Vol 59 (6) ◽  
pp. 1305-1310 ◽  
Author(s):  
Emad E. Abdel Aal ◽  
Mohamed M. Hefny

Galvanostatic anodization of lead in borate solutions reveals that lead can form a barrier type oxide film. The rate of growth, R, fulfils the empirical relation, R = aib within the current density i range from 1.16 .10-4 to 3.19 .10-4 A cm-2. The magnitudes of the parameters a and b are 6.9 . 103 and 1.6, respectively, it has been found that the high field approximation is applicable for the oxide growth on lead. The coefficients of the dependence of R on solution temperature, T, pH and borate ion concentration, c, viz. (∂R/∂T), (∂R/∂pH) and (∂R/∂log c) are -18 . 10-4, -0.13 and 0.41, respectively.


Materials ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 2841
Author(s):  
Zhiqiang Zhao ◽  
Lu Liu ◽  
Luofu Min ◽  
Wen Zhang ◽  
Yuxin Wang

Electrochemical oxidation, widely used in green production and pollution abatement, is often accompanied by the hydrogen evolution reaction (HER), which results in a high consumption of electricity and is a potential explosion hazard. To solve this problem, we report here a method for converting the original HER cathode into one that enables the oxygen reduction reaction (ORR) without having to build new electrolysis cells or be concerned about electrolyte leakage from the O2 gas electrode. The viability of this method is demonstrated using the electrolytic production of ammonium persulfate (APS) as an example. The original carbon black electrode for the HER is converted to an ORR electrode by first undergoing in situ anodization and then contacting O2 or air bubbled from the bottom of the electrode. With this sole change, APS production can achieve an electric energy saving of up to 20.3%. Considering the ease and low cost of this modification, such significant electricity savings make this method very promising in the upgrade of electrochemical oxidation processes, with wide potential applications.


Energies ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 3941
Author(s):  
Fangliang Zhong ◽  
Hassam Nasarullah Chaudhry ◽  
John Kaiser Calautit

To host the 2022 FIFA World Cup, Qatar is facing the greatest challenge in balancing the energy consumptions for cooling the stadiums and the thermal comfort for both players and spectators. Previous studies have not considered using a combined configuration of air curtain and roof cooling supply slot in stadiums to prevent the infiltration of outside hot air and reduce the cooling system’s energy consumption. This paper presents a Computational Fluid Dynamics (CFD) study of thermal and wind modeling around a baseline stadium and simulates the cooling scenarios of air curtains and roof cooling along with the energy consumption estimations for the World Cup matches using Building Energy Simulation (BES). Sensitivity analysis of different supply speeds and supply temperatures of air curtain gates and roof cooling was carried out, and the results showed that scenario six, which provides supply air of 25 m/s and 20 m/s at the roof and air curtain gates with a supply temperature of 10 °C, demonstrates optimal thermal performances on both the spectator tiers and the pitch. Compared with the baseline stadium performance, the average reductions in temperature on the pitch and spectator tiers under scenario six could reach 15 °C and 14.6 °C. The reductions in the Predicted Percentage of Dissatisfied values for the upper and lower tiers as well as the pitch were 63%, 74%, and 78%. In terms of the estimated energy consumptions, scenario six would consume electric energy per match at a rate of 25.5 MWh compared with 22.8 MWh for one of the stadiums in the 2010 South Africa World Cup and 42.0 MWh for the 2006 Germany World Cup. Future research is recommended to explore the influence of supply angle on air curtain gates and roof cooling supply slots’ performances.


2021 ◽  
Vol 13 (8) ◽  
pp. 4180
Author(s):  
Andrzej Czerepicki ◽  
Tomasz Krukowicz ◽  
Anna Górka ◽  
Jarosław Szustek

The article presents an analysis of priority solutions for trams at a selected sequence of intersections in Warsaw (Poland). An analysis of the literature has shown the topicality of this issue. A computer simulation model of a coordinated sequence of intersections was constructed. Three test scenarios were designed: the existing control system, the new coordinated fixed-time control system, and the adaptive control system with active priority. In the simulation process, detailed travel characteristics of trams and other traffic participants in a selected section were obtained for the three varying scenarios. Electric energy consumption for traction needs and pollutant emissions was then estimated for each of the variants. It was concluded that for the analyzed configuration, implementation of the adaptive priority will result in a reduction of tram time losses by up to 25%, a reduction in energy consumption by up to 23%, and a reduction in the emission of pollutants from individual vehicles by up to 3% in relation to the original variant. The conducted research may be the basis for a comprehensive method of assessing the effectiveness of applying the adaptative priority when designing new tramway lines and modernizing the existing ones.


Energies ◽  
2019 ◽  
Vol 12 (21) ◽  
pp. 4046 ◽  
Author(s):  
Sooyoun Cho ◽  
Jeehang Lee ◽  
Jumi Baek ◽  
Gi-Seok Kim ◽  
Seung-Bok Leigh

Although the latest energy-efficient buildings use a large number of sensors and measuring instruments to predict consumption more accurately, it is generally not possible to identify which data are the most valuable or key for analysis among the tens of thousands of data points. This study selected the electric energy as a subset of total building energy consumption because it accounts for more than 65% of the total building energy consumption, and identified the variables that contribute to electric energy use. However, this study aimed to confirm data from a building using clustering in machine learning, instead of a calculation method from engineering simulation, to examine the variables that were identified and determine whether these variables had a strong correlation with energy consumption. Three different methods confirmed that the major variables related to electric energy consumption were significant. This research has significance because it was able to identify the factors in electric energy, accounting for more than half of the total building energy consumption, that had a major effect on energy consumption and revealed that these key variables alone, not the default values of many different items in simulation analysis, can ensure the reliable prediction of energy consumption.


2012 ◽  
Vol 16 (3) ◽  
pp. 131
Author(s):  
Didik Ariwibowo

Didik Ariwibowo, in this paper explain that energy audit activities conducted through several phases, namely: the initial audit, detailed audit, analysis of energy savings opportunities, and the proposed energy savings. Total energy consumed consists of electrical energy, fuel, and materials in this case is water. Electrical energy consumption data obtained from payment of electricity accounts for a year while consumption of fuel and water obtained from the payment of material procurement. From the calculation data, IKE hotels accounted for 420.867 kWh/m2.tahun, while the IKE standards for the hotel is 300 kWh/m2.tahun. Thus, IKE hotel included categorized wasteful in energy usage. The largest energy consumption on electric energy consumption. Largest electric energy consumption is on the air conditioning (AC-air conditioning) that is equal to 71.3%, and lighting and electrical equipment at 27.28%, and hot water supply system by 4.44%. Electrical energy consumption in AC looks very big. Ministry of Energy and Mineral Resources of the statutes, the profile of energy use by air conditioning at the hotel by 48.5%. With these considerations in the AC target for audit detail as the next phase of activity. The results of a detailed audit analysis to find an air conditioning system energy savings opportunities in pumping systems. Recommendations on these savings is the integration of automation on the pumping system and fan coil units (FCU). The principle of energy conservation in the pumping system is by installing variable speed drives (VSD) pump drive motor to adjust speed according to load on the FCU. Load variations FCU provide input on the VSD pumps to match. Adaptation is predicted pump can save electricity consumption up to 65.7%. Keywords: energy audit, IKE, AC


Sign in / Sign up

Export Citation Format

Share Document