scholarly journals To Coat or Not To Coat: A question on porosity and coating in building material

2018 ◽  
Vol 67 ◽  
pp. 04040
Author(s):  
Diandra Pandu Saginatari ◽  
Yandi Andri Yatmo

Building material has been one of the aspects in architecture that directly relate with the overall building performance. Nowadays, porous traditional building material, such as bricks, stones, concrete, is still preferred due to its performance of porosity that supports passive cooling and reduces the building’s energy consumption. However, the porosity of building material could also cause many problems, such as damp, fungal and moss growth, that could cause deterioration of the building leading to the practice of coating. This paper questions how the act of coating often seen as a way of keeping the building in perfect condition with disregard to the building material’s porosity. It investigates how the different mechanism of porosity in building material in turns triggers a different act of coating. Furthermore, this paper argues that the act of coating should consider the performance of porosity to achieve a better building performance, not just regarding the energy efficiency but also the ecological sensibility towards the environment.

2016 ◽  
Vol 20 (suppl. 5) ◽  
pp. 1501-1510 ◽  
Author(s):  
Aleksandar Andjelkovic ◽  
Jovan Petrovic ◽  
Miroslav Kljajic

The research analyses the double skin fa?ades concept and their impact on the energy efficiency of buildings. This kind of fa?ade system has the ability to increase the energy efficiency and flexibility of buildings, while improving the quality of the indoor environment. The best way to develop and evaluate this complex type of building structure is the use of total building performance simulation in combination with experimental data. The overall research plan is based on experimental work, the process of validation and the numerical simulation of the validated model. Thus, the task of this part of the research is a comparative analysis between the current state of a building with double skin fa?ades and models with traditional envelope type. The main question that arises is whether and how the double skin fa?ades may contribute to the decrease in the energy consumption of the building by increasing the quality of the thermal comfort of the occupants. The simulation software tool, EnergyPlus in combination with airflow network algorithm, is used for modelling and all necessary energy calculations. The validated model in the analysis is used for comparative evaluation with models with traditional fa?ades. The simulation results for all the models analysed assess what their impact is on the energy consumption for heating and air-conditioning of the building. Comparing to models with traditional fa?ade, the energy analysis shows justification in the climatic conditions of Belgrade. Additionally, simulations results highlighted the necessity for an adequate control strategy of the double skin fa?ades application.


2019 ◽  
Vol 8 (1) ◽  
pp. 1 ◽  
Author(s):  
Leila Seidabadi ◽  
Hossein Ghadamian ◽  
Mohammad Aminy

In this research, a comprehensive simulation study including 3-D Dynamic time-dependent has been performed for Phase Change Materials (PCMs) applicant as a thermal storage integrated with the wind-catcher-wall in order to reduce the temperature difference (As a sustainable cooling method) in the MATLAB open-source–code software. By means of 3-D Dynamic time-dependent, as a final finding, the temperature drop (Cooling purpose) was obtained 25 degrees at about 7 working hours. Passive cooling can be considered as a viable and attractive strategy for the sustainable concept, opposed to mitigation of energy consumption and Green House Gas (GHG) simultaneously. One of the traditional-old-age famous passive cooling systems that are still being applied nowadays is wind-catcher as an energy system. The wind catcher sustain natural ventilation and cooling in buildings through wind-driven airflow as well as temperature difference. Windcatchers can save the electrical energy used to provide thermal comfort during the hot climate in summer case of the year, especially during the peak hours contributed to energy carriers’ consumptions. In this study, by proposing a new design of the windcatchers, attempts have been made to improve the energy efficiency of passive cooling methods. Besides, the application of new efficient methods for the purpose of thermal energy storage (PCM) as a sub-system is a chosen method to increase energy efficiency. By applying energy storage systems in addition to increase system energy performance and reliability, the target of reducing energy consumption is achieved.© 2019. CBIORE-IJRED. All rights reservedArticle History: Received May 18th 2018; Received in revised form October 5th  2018; Accepted January 5th 2019; Available onlineHow to Cite This Article: Seidabadi, L., Ghadamian, H, and Aminy, M. (2019) A Novel Integration of PCM with Wind-Catcher Skin Material in Order to Increase Heat Transfer Rate. Int. Journal of Renewable Energy Development, 8(1), 1-6.https://doi.org/10.14710/ijred.8.1.1-6


2020 ◽  
pp. 50-64
Author(s):  
Kuladeep Kumar Sadevi ◽  
Avlokita Agrawal

With the rise in awareness of energy efficient buildings and adoption of mandatory energy conservation codes across the globe, significant change is being observed in the way the buildings are designed. With the launch of Energy Conservation Building Code (ECBC) in India, climate responsive designs and passive cooling techniques are being explored increasingly in building designs. Of all the building envelope components, roof surface has been identified as the most significant with respect to the heat gain due to the incident solar radiation on buildings, especially in tropical climatic conditions. Since ECBC specifies stringent U-Values for roof assembly, use of insulating materials is becoming popular. Along with insulation, the shading of the roof is also observed to be an important strategy for improving thermal performance of the building, especially in Warm and humid climatic conditions. This study intends to assess the impact of roof shading on building’s energy performance in comparison to that of exposed roof with insulation. A typical office building with specific geometry and schedules has been identified as base case model for this study. This building is simulated using energy modelling software ‘Design Builder’ with base case parameters as prescribed in ECBC. Further, the same building has been simulated parametrically adjusting the amount of roof insulation and roof shading simultaneously. The overall energy consumption and the envelope performance of the top floor are extracted for analysis. The results indicate that the roof shading is an effective passive cooling strategy for both naturally ventilated and air conditioned buildings in Warm and humid climates of India. It is also observed that a fully shaded roof outperforms the insulated roof as per ECBC prescription. Provision of shading over roof reduces the annual energy consumption of building in case of both insulated and uninsulated roofs. However, the impact is higher for uninsulated roofs (U-Value of 3.933 W/m2K), being 4.18% as compared to 0.59% for insulated roofs (U-Value of 0.33 W/m2K).While the general assumption is that roof insulation helps in reducing the energy consumption in tropical buildings, it is observed to be the other way when insulation is provided with roof shading. It is due to restricted heat loss during night.


2020 ◽  
Vol 14 ◽  
Author(s):  
M. Sivaram ◽  
V. Porkodi ◽  
Amin Salih Mohammed ◽  
S. Anbu Karuppusamy

Background: With the advent of IoT, the deployment of batteries with a limited lifetime in remote areas is a major concern. In certain conditions, the network lifetime gets restricted due to limited battery constraints. Subsequently, the collaborative approaches for key facilities help to reduce the constraint demands of the current security protocols. Aim: This work covers and combines a wide range of concepts linked by IoT based on security and energy efficiency. Specifically, this study examines the WSN energy efficiency problem in IoT and security for the management of threats in IoT through collaborative approaches and finally outlines the future. The concept of energy-efficient key protocols which clearly cover heterogeneous IoT communications among peers with different resources has been developed. Because of the low capacity of sensor nodes, energy efficiency in WSNs has been an important concern. Methods: Hence, in this paper, we present an algorithm for Artificial Bee Colony (ABC) which reviews security and energy consumption to discuss their constraints in the IoT scenarios. Results: The results of a detailed experimental assessment are analyzed in terms of communication cost, energy consumption and security, which prove the relevance of a proposed ABC approach and a key establishment. Conclusion: The validation of DTLS-ABC consists of designing an inter-node cooperation trust model for the creation of a trusted community of elements that are mutually supportive. Initial attempts to design the key methods for management are appropriate individual IoT devices. This gives the system designers, an option that considers the question of scalability.


2015 ◽  
Vol 8 (1) ◽  
pp. 206-210 ◽  
Author(s):  
Yu Junyang ◽  
Hu Zhigang ◽  
Han Yuanyuan

Current consumption of cloud computing has attracted more and more attention of scholars. The research on Hadoop as a cloud platform and its energy consumption has also received considerable attention from scholars. This paper presents a method to measure the energy consumption of jobs that run on Hadoop, and this method is used to measure the effectiveness of the implementation of periodic tasks on the platform of Hadoop. Combining with the current mainstream of energy estimate formula to conduct further analysis, this paper has reached a conclusion as how to reduce energy consumption of Hadoop by adjusting the split size or using appropriate size of workers (servers). Finally, experiments show the effectiveness of these methods as being energy-saving strategies and verify the feasibility of the methods for the measurement of periodic tasks at the same time.


2021 ◽  
Vol 236 ◽  
pp. 110772
Author(s):  
Carmela Vetromile ◽  
Antonio Spagnuolo ◽  
Antonio Petraglia ◽  
Antonio Masiello ◽  
Maria Rosa di Cicco ◽  
...  

Energies ◽  
2021 ◽  
Vol 14 (14) ◽  
pp. 4089
Author(s):  
Kaiqiang Zhang ◽  
Dongyang Ou ◽  
Congfeng Jiang ◽  
Yeliang Qiu ◽  
Longchuan Yan

In terms of power and energy consumption, DRAMs play a key role in a modern server system as well as processors. Although power-aware scheduling is based on the proportion of energy between DRAM and other components, when running memory-intensive applications, the energy consumption of the whole server system will be significantly affected by the non-energy proportion of DRAM. Furthermore, modern servers usually use NUMA architecture to replace the original SMP architecture to increase its memory bandwidth. It is of great significance to study the energy efficiency of these two different memory architectures. Therefore, in order to explore the power consumption characteristics of servers under memory-intensive workload, this paper evaluates the power consumption and performance of memory-intensive applications in different generations of real rack servers. Through analysis, we find that: (1) Workload intensity and concurrent execution threads affects server power consumption, but a fully utilized memory system may not necessarily bring good energy efficiency indicators. (2) Even if the memory system is not fully utilized, the memory capacity of each processor core has a significant impact on application performance and server power consumption. (3) When running memory-intensive applications, memory utilization is not always a good indicator of server power consumption. (4) The reasonable use of the NUMA architecture will improve the memory energy efficiency significantly. The experimental results show that reasonable use of NUMA architecture can improve memory efficiency by 16% compared with SMP architecture, while unreasonable use of NUMA architecture reduces memory efficiency by 13%. The findings we present in this paper provide useful insights and guidance for system designers and data center operators to help them in energy-efficiency-aware job scheduling and energy conservation.


Energies ◽  
2021 ◽  
Vol 14 (14) ◽  
pp. 4209
Author(s):  
Rita Remeikienė ◽  
Ligita Gasparėnienė ◽  
Aleksandra Fedajev ◽  
Marek Szarucki ◽  
Marija Đekić ◽  
...  

The main goal of setting energy efficiency priorities is to find ways to reduce energy consumption without harming consumers and the environment. The renovation of buildings can be considered one of the main aspects of energy efficiency in the European Union (EU). In the EU, only 5% of the renovation projects have been able to yield energy-saving at the deep renovation level. No other study has thus far ranked the EU member states according to achieved results in terms of increased usage in renewable sources, a decrease in energy usage and import, and reduction in harmful gas emissions due to energy usage. The main purpose of this article is to perform a comparative analysis of EU economies according to selected indicators related to the usage of renewable resources, energy efficiency, and emissions of harmful gasses as a result of energy usage. The methodological contribution of our study is related to developing a complex and robust research method for investment efficiency assessment allowing the study of three groups of indicators related to the usage of renewable energy sources, energy efficiency, and ecological aspects of energy. It was based on the PROMETHEE II method and allows testing it in other time periods, as well as modifying it for research purposes. The EU member states were categorized by such criteria as energy from renewables and biofuels, final energy consumption from renewables and biofuels, gross electricity generation from renewables and biofuels and import dependency, and usage of renewables and biofuels for heating and cooling. The results of energy per unit of Gross Domestic Product (GDP), Greenhouse gasses (GHG) emissions per million inhabitants (ECO2), energy per capita, the share of CO2 emissions from public electricity, and heat production from total CO2 emissions revealed that Latvia, Sweden, Portugal, Croatia, Austria, Lithuania, Romania, Denmark, and Finland are the nine most advanced countries in the area under consideration. In the group of the most advanced countries, energy consumption from renewables and biofuels is higher than the EU average.


2021 ◽  
Vol 11 (5) ◽  
pp. 2342
Author(s):  
Long Li ◽  
Zhongqu Xie ◽  
Xiang Luo ◽  
Juanjuan Li

Gait pattern generation has an important influence on the walking quality of biped robots. In most gait pattern generation methods, it is usually assumed that the torso keeps vertical during walking. It is very intuitive and simple. However, it may not be the most efficient. In this paper, we propose a gait pattern with torso pitch motion (TPM) during walking. We also present a gait pattern with torso keeping vertical (TKV) to study the effects of TPM on energy efficiency of biped robots. We define the cyclic gait of a five-link biped robot with several gait parameters. The gait parameters are determined by optimization. The optimization criterion is chosen to minimize the energy consumption per unit distance of the biped robot. Under this criterion, the optimal gait performances of TPM and TKV are compared over different step lengths and different gait periods. It is observed that (1) TPM saves more than 12% energy on average compared with TKV, and the main factor of energy-saving in TPM is the reduction of energy consumption of the swing knee in the double support phase and (2) the overall trend of torso motion is leaning forward in double support phase and leaning backward in single support phase, and the amplitude of the torso pitch motion increases as gait period or step length increases.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Muhammad Arif Budiyanto ◽  
Muhammad Hanzalah Huzaifi ◽  
Simon Juanda Sirait ◽  
Putu Hangga Nan Prayoga

AbstractSustainable development of container terminals is based on energy efficiency and reduction in CO2 emissions. This study estimated the energy consumption and CO2 emissions in container terminals according to their layouts. Energy consumption was calculated based on utility data as well as fuel and electricity consumptions for each container-handling equipment in the container terminal. CO2 emissions were estimated using movement modality based on the number of movements of and distance travelled by each container-handling equipment. A case study involving two types of container terminal layouts i.e. parallel and perpendicular layouts, was conducted. The contributions of each container-handling equipment to the energy consumption and CO2 emissions were estimated and evaluated using statistical analysis. The results of the case study indicated that on the CO2 emissions in parallel and perpendicular layouts were relatively similar (within the range of 16–19 kg/TEUs). These results indicate that both parallel and perpendicular layouts are suitable for future ports based on sustainable development. The results can also be used for future planning of operating patterns and layout selection in container terminals.


Sign in / Sign up

Export Citation Format

Share Document