scholarly journals Experimental study of accelerating early age concrete strength under elevated temperature, steaming, and chemical admixture addition of normal and high strength concrete

2018 ◽  
Vol 195 ◽  
pp. 01025
Author(s):  
Suryawan Murtiadi ◽  
Akmaluddin Akmaluddin ◽  
Buan Anshari ◽  
Suparjo Suparjo

Conventionally, curing is performed by moisturizing concrete periodically when the fresh concrete is still undergoing chemical reaction processes. This study is focused on early age concrete strength treated with special curing of early heating treatment and steaming. The addition of chemical accelerator and normal curing are also examined. Tests were conducted on normal and high strength concrete specimens. Treatments of the test specimens with steaming and early heating were carried out for 3 and 8 hours, respectively, at a temperature of about 70° C. Test results showed that concrete compressive strengths gained in 3-days compared to 28-days under normal curing, chemical accelerator, steam curing, and elevated temperature curing were 39%, 50%, 64% and 59%, respectively. While in 7-days were 66%, 75%, 80% and 83%, respectively. And in 14- days were 87%, 91%, 93% and 93%, respectively. For high-strength concrete, the compressive strengths gained in 3-days were 37%, 62%, 68% and 71%, respectively. The strengths in 7-days were 65%, 77%, 83% and 82%, respectively. And in 14-days were 85%, 89%, 90% and 93%, respectively. Test results indicated that the additions of chemical accelerator, steam and elevated temperature curing in order to obtain the high early age concrete strengths are highly recommended.

2010 ◽  
Vol 163-167 ◽  
pp. 1403-1408
Author(s):  
Feng Liu ◽  
Gui Xuan Chen ◽  
Li Juan Li

The effects of recycled rubber powder on working abilities, density and compressive strength of high strength concrete (HSC) at room temperature were studied in this paper. The characteristics of rubberized high strength concrete (RHSC) after fire was investigated by surface observation, weight loss and retained strength testing. The sieve number of rubber powder used in test is No.40 (420μm), No.60 (250µm) and No.80 (178µm), and the content of rubber powder filled in RHSC is 1%, 2%, 3% and 4% with respect to cementation material respectively. Test results show that the increase in rubber powder content reduces the concrete strength, while the decrease in compressive strength of RHSC is less than 10% when the content of rubber powder is within 2%. RHSC with small content of rubber (1%) can restrain the spalling failure of concrete under high temperature.


2013 ◽  
Vol 838-841 ◽  
pp. 42-46 ◽  
Author(s):  
Jun Jie Zeng ◽  
Zhi Hong Fan ◽  
Long Chen

The influence of metakaolin (MK) on strength and microstructure of steam-cured high-strength concrete has been investigated using compressive strength test, XRD, MIP and SEM. Three MK replacement levels were considered in the study: 5%, 10% and 15% by weight of cement. A mix double blended with 10% MK and 10% slag was prepared too. Test results have indicated that MK can increase the compressive strength of steam-cured concrete, especially at early age. Compressive strength up to 90MPa at 1 and 28 days is obtained with the incorporation of 10% MK and 10% slag. When the replacement level of MK is higher than 10%, the enhancement of strength becomes less significant. Content of Ca (OH)2 crystals is decreased while content of hydrates with Al is increased due to the pozzolanic reactivity of MK. Concrete pore structure is significantly refined and a denser hydrates structure is obtained due to the pozzolanic reaction and filler effect of MK. Meanwhile, combination of aggregate and paste is enhanced too. The improvements of strength and microstructure become more obvious when MK and slag are double incorporated.


2019 ◽  
Vol 23 (4) ◽  
pp. 614-629
Author(s):  
Shaohua Zhang ◽  
Xizhi Zhang ◽  
Shengbo Xu ◽  
Xingqian Li

This study reports the cyclic loading test results of normal-strength concrete-filled precast high-strength concrete centrifugal tube columns. Seven half-scale column specimens were tested under cyclic loads and axial compression loads to investigate their seismic behavior. The major parameters considered in the test included axial compression ratio, filled concrete strength, and volumetric stirrup ratio. The structural behavior of each specimen was investigated in terms of failure modes, hysteresis behavior, bearing capacity, dissipated energy, ductility, stiffness degradation, drift capacity, and strain profiles. Test results revealed that the concrete-filled precast high-strength concrete centrifugal tube column exhibited good integral behavior, and the failure modes of all columns were ductile flexural failures. Lower axial compression ratio and higher volumetric stirrup ratio resulted in more satisfactory ductile performance. In contrast, the filled concrete strength has a limited influence on the structural behavior of concrete-filled precast high-strength concrete centrifugal tube columns. Based on the limit analysis method, the calculation formula for the bending capacity of the concrete-filled precast high-strength concrete centrifugal tube column was developed, and the results predicted from the formulas were in good agreement with the experiment results.


2008 ◽  
Vol 400-402 ◽  
pp. 857-863
Author(s):  
Wei Jian Yi ◽  
Yan Mei Lv

19 RC beams with shear span-to-depth equal to 3 were tested under a stiff testing facility, and complete load-deflection curves including the post-peak branch were obtained. Based on the test results the effects of concrete strength, stirrups strength, inclined stirrup angle, the amount of longitudinal reinforcement on failure mode, shear ductility index and shear capacity were analyzed. The test results were compared with the shear design approaches of Chinese Code and American Code. The results indicate that the shear failure of beam with appropriate web reinforcement has finite ductility. High-strength concrete beams with high-strength stirrups can increase not only the shear capacity, but also the shear ductility. The shear capacity of beams with high-strength concrete and stirrup can be designed with Chinese Code, but shear capacity of high-strength concrete beams without stirrups, or with the smaller amount of longitudinal reinforcement, and normal strength concrete beams with high-strength stirrups may be over-estimated by the Code.


2011 ◽  
Vol 121-126 ◽  
pp. 126-131 ◽  
Author(s):  
Qing Lei Xu ◽  
Tao Meng ◽  
Miao Zhou Huang

In this paper, effects of nano-CaCO3 on compressive strength and Microstructure of high strength concrete in standard curing temperature(21±1°C) and low curing temperature(6.5±1°C) was studied. In order to improve the early strength of the concrete in low temperature, the early strength agent calcium nitrite was added into. Test results indicated that 0.5% dosage of nano-CaCO3 could inhibit the effect of calcium nitrite as early strength agent, but 1% and 2% dosage of nano-CaCO3 could improve the strength of the concrete by 13% and 18% in standard curing temperature and by 17% and 14% in low curing temperature at the age of 3days. According to the XRD spectrum, with the dosage up to 1% to 2%, nano-CaCO3 can change the orientation index significantly, leading to the improvement of strength of concrete both in standard curing temperature and low curing temperature.


2020 ◽  
Vol 10 (2) ◽  
pp. 642 ◽  
Author(s):  
Luís Bernardo ◽  
Sérgio Lopes ◽  
Mafalda Teixeira

This article describes an experimental program developed to study the influence of longitudinal prestress on the behaviour of high-strength concrete hollow beams under pure torsion. The pre-cracking, the post-cracking and the ultimate behaviour are analysed. Three tests were carried out on large hollow high-strength concrete beams with similar concrete strength. The variable studied was the level of longitudinal uniform prestress. Some important conclusions on different aspects of the beams’ behaviour are presented. These conclusions, considered important for the design of box bridges, include the influence of the level of prestress in the cracking and ultimate behaviour.


2014 ◽  
Vol 567 ◽  
pp. 381-386 ◽  
Author(s):  
Nasir Shafiq ◽  
Muhd Fadhil Nuruddin ◽  
Ali Elheber Ahmed Elshekh ◽  
Ahmed Fathi Mohamed Salih

In order to improve the mechanical properties of high strength concrete, HSC, several studies have been conducted using fly ash, FA. Researchers have made it possible to achieve 100-150MPa high strength concrete. Despite the popularity of this FAHSC, there is a major shortcoming in that it becomes more brittle, resulting in less than 0.1% tensile strain. The main objective of this work was to evaluate the fresh and hardened properties of FAHSC utilizing chopped basalt fiber stands, CBFS, as an internal strengthening addition material. This was achieved through a series of experimental works using a 20% replacement of cement by FA together with various contents of CBFS. Test results of concrete mixes in the fresh state showed no segregation, homogeneousness during the mixing period and workability ranging from 60 to 110 mm. Early and long terms of compressive strength did not show any improvement by using CBFS; in fact, it decreased. This was partially substituted by the effect of FA. Whereas, the split and flexural strengths of FASHC were significantly improved with increasing the content of CBFS as well as the percentage of the split and flexural tensile strength to the compressive strength. Also, test results showed a progressive increase in the areas under the stress-strain curves of the FAHSC strains after the CBFS addition. Therefore, the brittleness and toughness of the FAHSC were enhanced and the pattern of failure moved from brittle failure to ductile collapse using CBFS. It can be considered that the CBFS is a suitable strengthening material to produce ductile FAHSC.


2016 ◽  
Vol 857 ◽  
pp. 183-188
Author(s):  
C. Mohan Lal ◽  
Vontary Sai Srujan Reddy

High strength concrete has become a design requirement in recent years due to increase in number of infrastructure projects. This paper presents the effect of incorporating Ultra Fine Slag (UFS) and steel fibre to obtain high strength concrete. To achieve target strength of about 80 MPa, it is proposed to the replacement of cement of 10%, 20% and 30% with UFS and incorporating 0.5% and 1.0% fibre in concrete. An experimental investigation is carried out to find the mechanical properties of the concrete. From the test results, it was observed that a compressive strength of 95 MPa was achieved at 30% replacement of cement with UFS and 1.0% fibre content. In addition, there was a significant improvement in split tensile strength and flexural strength of the concrete. This study demonstrates that a high strength concrete can be obtained from partial replacement of cement with UFS and addition of steel fibre.