scholarly journals Characterization of Shear Strength of FRP Anchors

2018 ◽  
Vol 199 ◽  
pp. 09008
Author(s):  
Philipp Mahrenholtz ◽  
Jae-Yeol Cho ◽  
Ja-Min Park ◽  
Rolf Eligehausen

A critical performance aspect of FRP retrofitted concrete elements is the bonding of the FRP sheet to the concrete surface. In general, the performance is limited by the debonding of the loaded FRP sheets from the concrete surface. One method to delay debonding and enhance the capacity is the use of FRP anchors which interlock the FRP sheet to the concrete body. FRP anchors are made of rolled FRP fibres epoxied into in predrilled boreholes. There are a considerable number of studies on FRP strengthening methods available, and also FRP anchors attract more attention of the research community recently. However, to date FRP anchors were tested in a system together with the FRP sheet attached to the concrete, inhibiting the development of general design models. Moreover, the anchor behaviour was never tested for cyclic loads, though most applications are for seismic retrofitting schemes and cyclic shear loading generally results in reduced load capacity due to fatigue failure. To overcome the deficit in knowledge, shear tests on various FRP anchors were carried out. For these tests, FRP anchors were installed in concrete specimens on a separating steel section. The FRP anchor was then directly loaded to determine the capacity of the isolated component. This paper describes the testing approach and procedure. Details on the experimental results for static tests are presented and an outlook on seismic tests is given.

Buildings ◽  
2022 ◽  
Vol 12 (1) ◽  
pp. 41
Author(s):  
Moo-Won Hur ◽  
Yonghun Lee ◽  
Min-Jun Jeon ◽  
Sang-Hyun Lee

In this study, the Kagome truss damper, a metallic wire structures, was introduced and its mechanical properties were investigated through theoretical analyses and experimental tests. The yield strength of the Kagome damper is dependent on the geometric shape and diameter of the metallic wire. The Kagome damper has higher resistance to plastic buckling as well as lower anisotropy. Cyclic shear loading tests were conducted to investigate the energy dissipation capacity and stiffness/strength degradation by repeated loadings. The hysteretic properties obtained from the tests suggest that a modification of the ideal truss model with a hinged connection could be used to predict the yield strength and stiffness of the damper. For seismic retrofitting of a low-rise RC moment frame system, a wall-type Kagome damping system (WKDS) was proposed. The effectiveness of the proposed system was verified by conducting cyclic loading tests using a RC frame with/without the WKDS (story drift ratio limit 1.0%). The test results indicated that both the strength and stiffness of the RC frame increased to the target level and that its energy dissipation capacity was significantly enhanced. Nonlinear static and dynamic analyses were carried out to validate that the existing building structure can be effectively retrofitted using the proposed WKDS.


PCI Journal ◽  
1996 ◽  
Vol 41 (3) ◽  
pp. 64-80 ◽  
Author(s):  
Khaled A. Soudki ◽  
Jeffrey S. West ◽  
Sami H. Rizkalla ◽  
Bruce Blackett

Lab on a Chip ◽  
2021 ◽  
Author(s):  
YUHAO QIANG ◽  
Jia Liu ◽  
Ming Dao ◽  
E Du

Red blood cells (RBCs) are subjected to recurrent changes in shear stress and oxygen tension during blood circulation. The cyclic shear stress has been identified as an important factor that...


Author(s):  
Askar Zh. Zhussupbekov ◽  
Yoshinori Iwasaki ◽  
Abdulla R. Omarov

At the present time, in Astana city is going on works by construction public transport system LRT (Light Railway Transport). LRT is an overhead road with two railway lines. The first stage of construction is including construction of overhead road (bridge) with 22,4 km length and 18 stations. The foundation of bridge is the bored piles with cross-section 1.0HL5 m and length 8-КЗ 5 m. In these conditions, very important to control integrity of concrete body of each bored piles. For checking integrity- applying two methods - Low Strain Method and Cross-Hole Sonic Logging. The aim of this paper is to discuss the advantages and disadvantages of each method using the examples of a real application. The article presents loading tests of large diameter and deep boring piles on the construction site in new capital city of the Republic of Kazakhstan. Finally, some recommendations for testmg methods suitable for problematical ground conditions of Kazakhstan are introduced. Traditionally, pile load tests in Kazakhstan are carried out using static loading test methods. Static pile loading test is the most reliable method to obtain the load-settlement relation of piles. Results of static pile tests using the static compression loading test (by ASTM). static loading test (by GOST) and bi-direction static loading test (by ASTM) methods are presented in this paper. Experienced bored piles with length of 31.5 m. diameter 1000 mm. Hereafter the results of underground testmg by the piles with the methods of vertical static tests of SLT. BDSLT and SCLT are presented, which had been made on Expo 2017 projects, buildings of Pavilion m Astana. Kazakhstan.


Sign in / Sign up

Export Citation Format

Share Document