scholarly journals Interior Materials Combination and Perceived Indoor Air Quality

2019 ◽  
Vol 279 ◽  
pp. 03001
Author(s):  
Ingrid Juhasova Senitkova

The materials used in the buildings, either as surface structural materials or as furnishings, are mostly the sources of indoor air pollution. Interior surfaces are generally accepted as the main source of indoor TVOCs emissions. The poor indoor microclimate quality can cause the sick building syndrome, as well as negatively affects the people activities and wellbeing. In recent years the needs of indoor air quality and building performance improvement have been increasing. The indoor materials impact on perceived indoor air quality for various surface interior materials and its combination was studied within this paper. Traditional and progressive materials comparison reveals new fact regarding the TVOCs concentration. The task of the study was to investigate the possibility using individual material surfaces sorption ability. The chemical analysis and sensory assessments identifies health adverse of indoor air pollutants (TVOCs). Also we can use knowledge about the targeted use of sorption effect already in the building design phase. The results demonstrate the various sorption abilities of various indoor materials as well as various sorption ability of the same indoor material in various combinations.

2018 ◽  
Vol 10 (3) ◽  
pp. 299
Author(s):  
Erin Verayani

Indoor air pollution was one of the factors causing global health problems because most people do activities in the room contaminated by pollutant materials. AC system was one of the factors that influence the air quality of the room. Improper maintenance  to central air conditioning that was potentially as a breeding place for pathogenic microorganisms such as Legionella bacteria and decrease indoor air quality causing health problems of workers that is sick building syndrome. The purpose of this research was to know the existence of Legionella pathogen bacteria, indoor air quality such as physical and air bacteria number and sick building syndrome complaints on the officer at Blood Transfusion Installation of Dr.Soetomo Hospital. This study was an observational study with cross sectional study design and the results are compared with Minister of Health Decree No.1204 / Menkes / SK / X / 2004 about environmental health requirements of hospitals and Permenkes RI No.83 of 2014 about Blood Transfusion Unit. The results of identification in the water distribution system for clean water and AC Central using BCYE culture method was not found Legionella bacteria. The result of the measurement of the number of airborne germs has fulfilled the health requirements according to Minister of health Decree No.1204 / Menkes / SK / X / 2004 Environmental Health Requirements of hospital but the result of physical quality (temperature and humidity) was more than standart RI Minister of health Decree No.1204 / Menkes / SK / X / 2004 and Rule of Health Minister No.83/2014 about  Blood Transfusion Unit. The result of this study showed that 84% staffs get sick building syndrome complaint. The most sick building syndrome complaints were dry eye (66,7%) and nasal congestion (61,9%).


Author(s):  
Vinh Van Tran ◽  
Duckshin Park ◽  
Young-Chul Lee

Indoor air pollution (IAP) is a serious threat to human health, causing millions of deaths each year. A plethora of pollutants can result in IAP; therefore, it is very important to identify their main sources and concentrations and to devise strategies for the control and enhancement of indoor air quality (IAQ). Herein, we provide a critical review and evaluation of the major sources of major pollutant emissions, their health effects, and issues related to IAP-based illnesses, including sick building syndrome (SBS) and building-related illness (BRI). In addition, the strategies and approaches for control and reduction of pollutant concentrations are pointed out, and the recent trends in efforts to resolve and improve IAQ, with their respective advantages and potentials, are summarized. It is predicted that the development of novel materials for sensors, IAQ-monitoring systems, and smart homes is a promising strategy for control and enhancement of IAQ in the future.


Author(s):  
Gabriela Ventura Silva ◽  
Anabela O. Martins ◽  
Susana D. S. Martins

Indoor air pollution has obtained more attention in a moment where “stay at home” is a maximum repeated for the entire world. It is urgent to know the sources of pollutants indoors, to improve the indoor air quality. This study presents some results obtained for twelve incense products, used indoors, at home, and in temples, but also in spa centers or yoga gymnasiums, where the respiratory intensity is high, and the consequences on health could be more severe. The focus of this study was the gaseous emissions of different types of incense, performing a VOC screening and identifying some specific VOCs different from the usual ones, which are known or suspected to cause severe chronic health effects: carcinogenic, mutagenic, and reprotoxic. Thirteen compounds were selected: benzene, toluene, styrene, naphthalene, furfural, furan, isoprene, 2-butenal, phenol, 2-furyl methyl ketone, formaldehyde, acetaldehyde, and acrolein. The study also indicated that incense cone type shows a higher probability of being more pollutant than incense stick type, as from the 12 products tested, four were cone type, and three of them were in the group of the four higher polluters. Benzene and formaldehyde presented worrying levels in the major part of the products, above guideline values established by the WHO. Unfortunately, there are no limit values established for indoor air for all the compounds studied, but this fact should not exempt us from taking action to alert the population to the potential dangers of using those products. From this study, acetaldehyde, acrolein, furfural, and furan emerge as compounds with levels to deserve attention.


2021 ◽  
Vol 13 (8) ◽  
pp. 4139
Author(s):  
Muriel Diaz ◽  
Mario Cools ◽  
Maureen Trebilcock ◽  
Beatriz Piderit-Moreno ◽  
Shady Attia

Between the ages of 6 and 18, children spend between 30 and 42 h a week at school, mostly indoors, where indoor environmental quality is usually deficient and does not favor learning. The difficulty of delivering indoor air quality (IAQ) in learning facilities is related to high occupancy rates and low interaction levels with windows. In non-industrialized countries, as in the cases presented, most classrooms have no mechanical ventilation, due to energy poverty and lack of normative requirements. This fact heavily impacts the indoor air quality and students’ learning outcomes. The aim of the paper is to identify the factors that determine acceptable CO2 concentrations. Therefore, it studies air quality in free-running and naturally ventilated primary schools in Chile, aiming to identify the impact of contextual, occupant, and building design factors, using CO2 concentration as a proxy for IAQ. The monitoring of CO2, temperature, and humidity revealed that indoor air CO2 concentration is above 1400 ppm most of the time, with peaks of 5000 ppm during the day, especially in winter. The statistical analysis indicates that CO2 is dependent on climate, seasonality, and indoor temperature, while it is independent of outside temperature in heated classrooms. The odds of having acceptable concentrations of CO2 are bigger when indoor temperatures are high, and there is a need to ventilate for cooling.


2021 ◽  
Author(s):  
Kamrie Sarnosky ◽  
Mark Benden ◽  
Leslie Cizmas ◽  
Annette Regan ◽  
Garett Sansom

Abstract Background: The COVID-19 pandemic has accelerated an already existing trend of individuals increasingly working remotely. With the growing popularity of remote working, specifically in a home office, there is a critical need to better understand and characterize the potential environmental differences between these two spaces. Indoor air pollution can have adverse health effects and impair cognitive functioning. Methods: This small pilot cohort study (N=22) recruited home and office workers to better understand the indoor air quality between these spaces. Air contaminants collected and assessed included PM10 and PM2.5, carbon dioxide (CO2), and total volatile organic compounds (TVOCs). Results: Findings showed a strong statistically significant increase in all measured variables within homes in comparison to traditional offices (p<0.001). For instance, The mean PM2.5 level in the traditional office space was 1.93 µg/m3 whereas it was more than twice this amount (5.97 µg/m3) in home offices.Conclusion: These results indicate that those who work from home are at increased risk due to longer exposures to higher levels of certain contaminants, the importance to better develop interventions to mitigate this reality is underscored by the fact that many workers will be moving to home-based offices in the coming years.


Author(s):  
Mohd Saleem ◽  
Mohd Adnan Kausar ◽  
Fahmida Khatoon ◽  
Sadaf Anwar ◽  
Syed Monowar Alam Shahid ◽  
...  

In many aspects of life quality, bio-contaminants and indoor air quality have had catastrophic consequences, including a negative impact on human health with an increased prevalence of allergic respiratory reactions, asthma, and infectious diseases. We aimed to evaluate the quality of indoor air environment and find out the association between human health and indoor air pollution and also to assess the physical health status of a group of Saudi and non-Saudi populations during this pandemic. Also, we aimed to assess the most common health condition or symptoms associated with ventilation. A questionnaire was distributed online to test indoor air quality, ventilation status, common signs and symptoms of any allergy or mental status and their relationship to certain variables. A total of 362 respondents were included. Before living in the current home, flu or Influenza and chapped lips were more prevalent than allergies and chapped lips signs while living in the current home. (12.2% , 10.8% vs. 18.5% , 13.55% before and after respectively) Multiple colds were the second most common symptom (10.2%). Hoarse voice and headaches were the least common symptoms experienced; each constituted 4.4%. During the COVID-19 Pandemic, most respondents wore a facemask, approximately 76.5%; and almost one-third of respondents had bright natural light inside the current home (43.1%). The presence of natural light within the current home was significantly associated with symptoms experienced during living in the current house (p<0.05). Natural sunlight exposure could decrease allergic symptoms and minor health problems associated with poor ventilation and air quality indoors. In current living homes, the majority of respondents never used air purifiers (72.9 percent). In order to get attention from people to enhance the quality and ventilation mechanism of indoor air, special care and awareness of the effects of the use of air purifiers on human health is needed.


2019 ◽  
Vol 14 (4) ◽  
pp. 93-109
Author(s):  
Abd Halid Abdullah ◽  
Yee Yong Lee ◽  
Eeydzah Aminudin ◽  
Yeong Huei Lee

The indoor air quality (IAQ) in office buildings should be assessed for public health concerns as it relates to work performance and productivity. Therefore, this paper aims to assess the IAQ in a university office building. From this investigation, the level of contaminated indoor air is examined, the significant causes and contributing factors of contaminated indoor air are determined and a recommendation to improve the existing condition has been proposed. The physical parameters measured include air temperature, air velocity, relative humidity, and concentrations of carbon dioxide (CO2), carbon monoxide (CO), sulphur dioxide (SO2), and also air particles. It was found that the number of air particles of 0.5 μm in diameter is about 197,748 particles/m3, while air particles of 5.0 μm in diameter is around 534 particles/m3. The collected data were then compared with a questionnaire and IAQ standards. In conclusion, the indoor air quality within the multi-storey central office building of Universiti Tun Hussein Onn Malaysia (UTHM) is acceptable and suitable for occupation even though there were countable symptoms of Sick Building Syndrome (SBS) among its occupants.


Sign in / Sign up

Export Citation Format

Share Document