The Effect Of Storage On Platelet Morpholog

1981 ◽  
Author(s):  
A Sturk ◽  
L M Burt ◽  
T Hakvoort ◽  
J W ten cate ◽  
N Crawford

Platelet concentrates were stored for one, two or three days at 4°C (unagitated) or room temperature (unagitated and linearly agitated). The morphology of platelets in platelet concentrates, directly after twice washing at room temperature and after 60 min incubation of the washed platelets at 37°C was investigated by both scanning and transmission electron microscopy.Platelets in the freshly prepared concentrates are slightly activated, i.e. show some pseudopod formation. At 4°C platelets rapidly loose their discoid shape. After three days their surface membrane shows extensive folding, they are slightly vacuolated and have lost most of their granules. Incubation of these cold-stored platelets at 37°C does not induce reversal to the discoid shape.Room temperature storage results in reversal of the slight initial platelet activation. After three days unagitated platelets are slightly more vacuolated than platelets stored with agitation. Room temperature storage usually results in remarkably well preserved, discoid platelets. Occasionally however, agitated platelet concentrates contain a high proportion of odd shaped cells. As platelets stored at 4°C did not became discoid after incubation at 37°, the altered membrane structure could provide an explanation for their short survival upon transfusion. Our results also provide a morphological correlation with the slightly better recovery and survival of platelets stored agitated vs.- non-agitated platelets at room temperature.

2020 ◽  
Vol 21 (3) ◽  
pp. 935
Author(s):  
Katrijn R. Six ◽  
Veerle Compernolle ◽  
Hendrik B. Feys

Platelet cryopreservation has been investigated for several decades as an alternative to room temperature storage of platelet concentrates. The use of dimethylsulfoxide as a cryoprotectant has improved platelet storage and cryopreserved concentrates can be kept at −80 °C for two years. Cryopreserved platelets can serve as emergency backup to support stock crises or to disburden difficult logistic areas like rural or military regions. Cryopreservation significantly influences platelet morphology, decreases platelet activation and severely abrogates platelet aggregation. Recent data indicate that cryopreserved platelets have a procoagulant phenotype because thrombin and fibrin formation kicks in earlier compared to room temperature stored platelets. This happens both in static and hydrodynamic conditions. In a clinical setting, low 1-h post transfusion recoveries of cryopreserved platelets represent fast clearance from circulation which may be explained by changes to the platelet GPIbα receptor. Cryopreservation splits the concentrate in two platelet subpopulations depending on GPIbα expression levels. Further research is needed to unravel its physiological importance. Proving clinical efficacy of cryopreserved platelets is difficult because of the heterogeneity of indications and the ambiguity of outcome measures. The procoagulant character of cryopreserved platelets has increased interest for use in trauma stressing the need for double-blinded randomized clinical trials in actively bleeding patients.


Author(s):  
A.J. Tousimis ◽  
T.R. Padden

The size, shape and surface morphology of human erythrocytes (RBC) were examined by scanning electron microscopy (SEM), of the fixed material directly and by transmission electron microscopy (TEM) of surface replicas to compare the relative merits of these two observational procedures for this type specimen.A sample of human blood was fixed in glutaraldehyde and washed in distilled water by centrifugation. The washed RBC's were spread on freshly cleaved mica and on aluminum coated microscope slides and then air dried at room temperature. The SEM specimens were rotary coated with 150Å of 60:40- gold:palladium alloy in a vacuum evaporator using a new combination spinning and tilting device. The TEM specimens were preshadowed with platinum and then rotary coated with carbon in the same device. After stripping the RBC-Pt-C composite film, the RBC's were dissolved in 2.5N HNO3 followed by 0.2N NaOH leaving the preshadowed surface replicas showing positive topography.


Author(s):  
S. Mahajan

The evolution of dislocation channels in irradiated metals during deformation can be envisaged to occur in three stages: (i) formation of embryonic cluster free regions, (ii) growth of these regions into microscopically observable channels and (iii) termination of their growth due to the accumulation of dislocation damage. The first two stages are particularly intriguing, and we have attempted to follow the early stages of channel formation in polycrystalline molybdenum, irradiated to 5×1019 n. cm−2 (E > 1 Mev) at the reactor ambient temperature (∼ 60°C), using transmission electron microscopy. The irradiated samples were strained, at room temperature, up to the macroscopic yield point.Figure 1 illustrates the early stages of channel formation. The observations suggest that the cluster free regions, such as A, B and C, form in isolated packets, which could subsequently link-up to evolve a channel.


Author(s):  
Jane Payne ◽  
Philip Coudron

This transmission electron microscopy (TEM) procedure was designed to examine a gram positive spore-forming bacillus in colony on various solid agar media with minimal artifact. Cellular morphology and organization of colonies embedded in Poly/Bed 812 resin (P/B) were studied. It is a modification of procedures used for undecalcified rat bone and Stomatococcus mucilaginosus.Cultures were fixed and processed at room temperature (RT) under a fume hood. Solutions were added with a Pasteur pipet and removed by gentle vacuum aspiration. Other equipment used is shown in Figure 3. Cultures were fixed for 17-18 h in 10-20 ml of RT 2% phosphate buffered glutaraldehyde (422 mosm/KgH2O) within 5 m after removal from the incubator. After 3 (30 m) changes in 0.15 M phosphate buffer (PB = 209-213 mosm/KgH2O, pH 7.39-7.41), colony cut-outs (CCO) were made with a scalpel.


Author(s):  
A.C. Daykin ◽  
C.J. Kiely ◽  
R.C. Pond ◽  
J.L. Batstone

When CoSi2 is grown onto a Si(111) surface it can form in two distinct orientations. A-type CoSi2 has the same orientation as the Si substrate and B-type is rotated by 180° degrees about the [111] surface normal.One method of producing epitaxial CoSi2 is to deposit Co at room temperature and anneal to 650°C.If greater than 10Å of Co is deposited then both A and B-type CoSi2 form via a number of intermediate silicides .The literature suggests that the co-existence of A and B-type CoSi2 is in some way linked to these intermediate silicides analogous to the NiSi2/Si(111) system. The phase which forms prior to complete CoSi2 formation is CoSi. This paper is a crystallographic analysis of the CoSi2/Si(l11) bicrystal using a theoretical method developed by Pond. Transmission electron microscopy (TEM) has been used to verify the theoretical predictions and to characterise the defect structure at the interface.


Author(s):  
Kazue Nishimoto ◽  
Miki Muraki ◽  
Ryuji Tamura

AbstractTernary Ag–In–(Eu, Ce) 1/1 approximants are synthesized and their structures are studied by transmission electron microscopy (TEM). For both the approximants, superlattice spots are clearly observed at room temperature, and the superstructures of the Ag–In–(Eu, Ce) approximants are found to be similar to those of Cd


Author(s):  
Tali H. Horst ◽  
Richard D. Smith ◽  
Antje Potthast ◽  
Martin A. Hubbe

AbstractThree copies of a book that had been optionally deacidified using two different procedures in 1967, and then subjected to accelerated aging, were tested again after 52 years of natural aging. Matched copies of the book Cooking the Greek Way, which had been printed in Czechoslovakia on acidic paper, were evaluated. Nonaqueous treatment of two of the copies with magnesium methoxide dissolved in chlorofluorocarbon solvent had been found in 1967 to have decreased the susceptibility to embrittlement, as evidenced by the results of the accelerated aging, followed by folding endurance tests. Retesting of the same books in 2019, after 52 years of room temperature storage, showed that the deacidification treatments had achieved the following benefits in comparison to the untreated book: (a) higher brightness; (b) higher folding endurance; (c) tensile breaking length higher in the cross-direction of the paper; (d) substantial alkaline reserve content, (e) an alkaline surface pH in the range 7.1–7.4, and (f) higher molecular mass of the cellulose. Remarkably, some of the folding endurance results matched those of unaged samples evaluated in 1967. Scanning electron micrographs showed no differences between the treated and untreated books.


2011 ◽  
Vol 678 ◽  
pp. 75-84 ◽  
Author(s):  
Marcello Cabibbo

Magnesium alloys containing rare earth elements are known to have high specific strength and corrosion resistance. The addition of SiC ceramic particles makes the metal matrix composite stronger with better wear and creep resistance and a still good machinability. The role of the reinforcement particles to the enhanced strength can be quantitatively evaluated using transmission electron microscopy (TEM). This paper presents a quantitative strengthening evaluation in a SiC Mg-RE composite alloy. The different contributions were determined by TEM inspections. The microstructure strengthening mechanism was studied after room temperature compression specimens. The way of combining the different contributions and the comparison to the measured yield stress, is also discussed and justified.


2011 ◽  
Vol 391-392 ◽  
pp. 225-229 ◽  
Author(s):  
Qing Hong Kong ◽  
Hong Liu ◽  
Yun Long Zhang ◽  
Yong Sheng Yan

Spindle-like bis (8-hydroxyquinoline) iron (FeQ3) complex has been synthesized with a facile method in a mixed solvent system at room temperature for 12 h. The molecular formula of the products is speculated by the C, H and N element analysis and thermal gravimetric analysis, and Fourier-transformation infrared spectroscopy was also utilized to measure its structure, which further confirm the molecular formula of the products. The observation of field emission scanning electron microscopy and transmission electron microscopy shows that the morphology of tris (8-hydroxyquinoline) iron complex is spindle-like structure. The photoluminescence of the products were also investigated. The results indicate that the photoluminescence emission of FeQ3spindles shows obvious blue shift contrasted with that of 8-hydroxyquinoline.


Sign in / Sign up

Export Citation Format

Share Document