scholarly journals Polymethylmethacrylate Incorporating Nanodiamonds for Denture Repair: In Vitro Study on the Mechanical Properties

Author(s):  
Mohammed Moustafa Ahmed Gad ◽  
Mohamed Saber Ali ◽  
Ahmad M. Al-Thobity ◽  
Yousif A. Al-Dulaijan ◽  
Mai El Zayat ◽  
...  

Abstract Objective This study aimed to evaluate the effect of nanodiamond (ND) addition to repair resin with repair gap modifications on the flexural and impact strength of repaired polymethylmethacrylate denture base. Materials and Methods Heat-polymerized acrylic resin specimens (N = 100/test) were prepared and sectioned to half creating two repair gaps: 2.5- and 0 mm with 45 degrees beveling. They were further divided into subgroups (n = 20) according to ND concentration (control, 0.25%ND, and 0.50%ND), thermocycling (500 cycles) was done to half the specimens in each subgroup. Flexural strength was tested using 3-point bending test and impact strength was tested by Charpy's impact test. Analysis of variance and post-hoc Tukey's tests were performed for data analysis (α = 0.05). Scanning electron microscope was employed for fracture surface analysis and ND distribution. Results Before and after thermocycling, the addition of ND significantly increased the flexural strength and elastic modulus in comparison to control group (p ˂ 0.001), while 0 mm repair gap showed insignificant difference between ND-reinforced groups (p ˃ 0.05). Regarding impact strength, ND addition increased the impact strength with 0 mm gap in comparison to control and 2.5 mm with ND (p˂0.001), while later groups showed no significant in between (p ˃ 0.05). Comparing thermocycling effect per respective concentration and repair gap, thermocycling adversely affected all tested properties except elastic modulus with 0 mm–0.25 and 0 mm–0.5% and impact strength with 2.5 mm, 2.5 mm–0.25%, 2.5 mm– 0.5% (p ˃ 0.05). Conclusion ND addition combined with decreased repair gap improved the flexural strength, elastic modulus, and impact strength of repaired denture resin, while thermocycling has a negative effect on denture repair strength.

2013 ◽  
Vol 14 (1) ◽  
pp. 80-83 ◽  
Author(s):  
Naveen S Yadav ◽  
Teerthesh Jain ◽  
Amrita Pandita ◽  
SMA Feroz ◽  
UK Kartika ◽  
...  

ABSTRACT Aim The purpose of this study was to evaluate and compare the flexural strength of commercially available acrylic (trevalone) and modified polymethylmethacrylate (PMMA). Materials and methods Four groups were tested; Group 1— control group regular MMA, group 2—2% methacrylic acid, 88% MMA, group 3—16% methacrylic acid, 84% MMA group 4— 20% methacrylic acid, 80% MMA 15 resin specimens of each group were polymerized. After processing, the specimens were subjected for flexural strength testing using three point bending test in a Universal Testing Machine. All data was statistically analyzed with one-way ANOVA, differences within the groups were analyzed by Scheffe's analysis. Results As the ratio of incorporated methacrylic acid to PMMA increased, the flexural strength decreased. Analysis of data revealed a significant decrease in flexural strength of specimens (p < 0.000) after incorporation of 12%, 16%, 20% methacrylic acid to heat polymerized acrylic resin, when compared with the control group. Lowest flexural strength was observed with specimens containing 20% methacrylic acid and highest flexural strength was observed with specimens containing conventional monomer without methacrylic acid. Conclusion It was observed that as the concentration of methacrylic acid in heat polymerized acrylic resin increases, the flexural strength decreases. Lowest flexural strength was observed with specimens containing 20% methacrylic acid and highest flexural strength was observed with specimens containing conventional monomer without methacrylic acid. Clinical significance The major advantages of addition of methacrylic acid to polymethylmethacrylate could be for the elderly people with restricted manual dexterity or cognitive disturbances, especially for patients who do not follow an adequate denture cleansing protocol and diabetic patients who are more susceptible for denture stomatitis. How to cite this article Jain T, Yadav NS, Pandita A, Feroz SMA, Kartika UK, Singh PP. A Comparative Evaluation of Flexural Strength of Commercially Available Acrylic and Modified Polymethylmethacrylate: An in vitro Study. J Contemp Dent Pract 2013;14(1):80-83.


2017 ◽  
Vol 8 (1) ◽  
pp. 15-19
Author(s):  
Sanjeev Singh, ◽  
Abid Z Hussain, ◽  
RU Thombare, ◽  
BK Motwani, ◽  
Shweta Singh,

ABSTRACT Aim To investigate the effect of variation in temperature and time intervals on the flexural strength of two brands of autopolymerizing resins polymerized at constant pressure. Materials and methods Two autopolymerizing resins RR Cold Cure resin (DPI) and RR-Rapid Repair Powder (Dentsply) were used. A total of 20 samples were fabricated for each group. Samples were polymerized at temperature ranges of 40°, 50°, 60°, and 70°C and at time intervals of 5, 10, and 15 minutes in the customized curing pot, maintaining pressure of 30 psi. Results Flexural strength was verified using universal testing machine using three-point bending test and was then compared with all samples and also with the samples cured in open air (control group). The samples cured at higher temperature, i.e., 60° and 70°C, have shown increased strength than those at 40° and 50°C as well as control group. Time interval of 10 minutes is considered sufficient to increase the strength of the resin, as per the results of this study. Conclusion The samples cured under varied condition of time and temperature but under constant pressure showed increased strength than those cured in open air. Clinical significance The effect of pressure and temperature has been demonstrated, which could be utilized for enhancing the durability of the prosthesis fabricated from autopolymerized resins. How to cite this article Singh S, Hussain AZ, Thombare RU, Motwani BK, Singh S, Mangalekar SB. An in vitro Study to evaluate the Effects of Various Polymerizing Conditions on the Flexural Strength of Autopolymerizing Resins. J Health Sci Res 2017;8(1):15-19.


2019 ◽  
Vol 2019 ◽  
pp. 1-11 ◽  
Author(s):  
Mohammed M. Gad ◽  
Ahmad M. Al-Thobity ◽  
Ahmed Rahoma ◽  
Reem Abualsaud ◽  
Fahad A. Al-Harbi ◽  
...  

This study is aimed at evaluating the hybrid reinforcement effects of zirconium oxide nanoparticles (nano-ZrO2) and glass fibers (GFs) at different ratios on the flexural and impact strengths of a polymethylmethacrylate (PMMA) denture base. A total of 160 specimens were fabricated from heat-polymerized acrylic resins using the water bath technique. For the control group, the specimens did not receive any additions; for the test group, different concentrations of nano-ZrO2/GFs at 5% of the PMMA polymer were added. The concentrations of nano-ZrO2/GFs were as follows: 5%–0%, 4%–1%, 3%–2%, 2.5%–2.5%, 2%–3%, 1%–4%, and 0%–5%. The flexural strength was measured using the three-point bending test. The impact strength was measured using the Charpy impact test. Results were tabulated and analyzed using one-way analysis of variance (ANOVA) and the Tukey–Kramer multiple comparison test (p≤0.05). The flexural and impact strengths of PMMA-nano-ZrO2 + GF composites were significantly improved when compared with those of pure PMMA (p<0.05). The maximum flexural strength (94.05 ± 6.95 MPa) and impact strength (3.89 ± 0.46 kJ/m2) were obtained with PMMA (2.5%)/nano-ZrO2 + 2.5% GF mixtures and could be used for removable prosthesis fabrication.


2021 ◽  
Vol 2114 (1) ◽  
pp. 012023
Author(s):  
Teba M. Hameed ◽  
Balqees M. Al-Dabbagh ◽  
Ragdaa K. Jasim

Abstract Materials and Methods: In total, 90 specimens were prepared to be used in the study. The specimens were divided into (3) main groups depended on the presence of sisal fibers powder, first group (30) specimens of heat cure PMMA without additives (control), second and third experimental groups of 60 specimens of heat cure PMMA with salinized sisal fibers powder with two different weight percentages (1 and 3%) wt. Three point bending test was used to measure the flexural strength of the specimens, while the impact strength was done by impact testing Charpy’s machine and tensile test was performed according to ASTM (D-638). Data analysis was performed using (ANOVA) test. The results of this study refer to a highly significant in the flexural strength and tensile strength of specimens reinforced with sisal fibers powder compared with control specimens. Non-significant difference was detected in impact strength among the reinforced groups and control gro. Reinforcement of acrylic resin with natural sisal fibers powder affects its flexural strength and tensile strength with non-significant in impact strength.


2009 ◽  
Vol 20 (2) ◽  
pp. 132-137 ◽  
Author(s):  
Rafael Leonardo Xediek Consani ◽  
Douglas Duenhas de Azevedo ◽  
Marcelo Ferraz Mesquita ◽  
Wilson Batista Mendes ◽  
Paulo César Saquy

The present study evaluated the effect of repeated simulated microwave disinfection on physical and mechanical properties of Clássico, Onda-Cryl and QC-20 denture base acrylic resins. Aluminum patterns were included in metallic or plastic flasks with dental stone following the traditional packing method. The powder/liquid mixing ratio was established according to the manufacturer's instructions. After water-bath polymerization at 74ºC for 9 h, boiling water for 20 min or microwave energy at 900 W for 10 min, the specimens were deflasked after flask cooling and finished. Each specimen was immersed in 150 mL of distilled water and underwent 5 disinfection cycles in a microwave oven set at 650 W for 3 min. Non-disinfected and disinfected specimens were subjected to the following tets: Knoop hardness test was performed with 25 g load for 10 s, impact strength test was done using the Charpy system with 40 kpcm, and 3-point bending test (flexural strength) was performed at a crosshead speed of 0.5 mm/min until fracture. Data were analyzed statistically by ANOVA and Tukey's test (α= 0.05%). Repeated simulated microwave disinfections decreased the Knoop hardness of Clássico and Onda-Cryl resins and had no effect on the impact strength of QC-20. The flexural strength was similar for all tested resins.


2018 ◽  
Vol 11 (3) ◽  
pp. 1573-1581 ◽  
Author(s):  
Maha M. Turki ◽  
Faiza M. Abdul-Ameer

Scleral acrylic resin is widely used to synthesize ocular prosthesis. However, the properties of this material change over time, thus requiring the prosthesis to be refabricated. Many studies were conducted to improve these properties by reinforcing this material with nanoparticles. This study aims to evaluate the effect of silver nanoparticle powder on the mechanical properties (transverse flexural strength, impact strength, shear bond strength, surface microhardness, and surface roughness) of scleral acrylic resin used for ocular prostheses. Two concentrations were selected from the pilot study and evaluated for their effects on scleral acrylic resin properties. According to the pilot study, 0.01 and 0.02wt% AgNPs powder improved the transverse flexural strength, microhardness, and surface roughness compared with other percentages. The specimens in the main study were divided into (3) main groups, (50) specimens without additives (control group A), (50) experimental specimens (with 0.01wt% AgNPs group B), and (50) experimental specimens (with 0.02 wt% AgNPs group C). Each group was subdivided into (5) equal subgroups depending on the tests used. The data were studied using one way ANOVA and post hoc LSD test. At 0.01 wt% AgNPs addition, the mean values of transverse flexural strength insignificantly increased (p> 0.05), and those of impact strength and shear bond strength significantly increased (p< 0.05) compared with those of the control group. At 0.02 wt% AgNPs addition (group C), the mean value of transverse flexural strength significantly increased (p< 0.05), that of impact strength insignificantly increased (p> 0.05), and that of shear bond strength increased with high significance (p< 0.01) compared with those of the control group. Group C showed insignificant increase in the mean values of transverse flexural strength, impact strength, and shear bond strength (p. 0.05) compared with group B. The scleral acrylic resin added with 0.01 and 0.02 wt% AgNPs showed insignificant increase in microhardness and insignificant decrease in surface roughness. The addition of AgNPs powder in both concentrations improved the mechanical properties of scleral acrylic resin used for ocular prostheses.


2021 ◽  
Vol 22 (18) ◽  
pp. 9986
Author(s):  
Giulia Brunello ◽  
Kathrin Becker ◽  
Luisa Scotti ◽  
Dieter Drescher ◽  
Jürgen Becker ◽  
...  

Several decontamination methods for removing biofilm from implant surfaces during surgical peri-implantitis treatment have been reported, including the intraoperative usage of chlorhexidine (CHX)-based antiseptics. There is a lack of information on possible adverse effects on bone healing. The study aimed to examine the impact of three CHX-based mouthwashes on osteoblast-like cells (SaOS-2) in vitro. Cells were cultured for three days in 96-well binding plates. Each well was randomly treated for either 30, 60 or 120 s with 0.05% CHX combined with 0.05% cetylpyridinium chloride (CPC), 0.1% CHX, 0.2% CHX or sterile saline (NaCl) as control. Cell viability, cytotoxicity and apoptosis were assessed at day 0, 3 and 6. Cell viability resulted in being higher in the control group at all time points. At day 0, the CHX 0.2 group showed significantly higher cytotoxicity values compared to CHX 0.1 (30 s), CHX + CPC (30 s, 60 s and 120 s) and control (60 s and 120 s), while no significant differences were identified between CHX + CPC and both CHX 0.1 and NaCl groups. All test mouthwashes were found to induce apoptosis to a lower extent compared to control. Results indicate that 0.2% CHX presented the highest cytotoxic effect. Therefore, its intraoperative use should be carefully considered.


Sign in / Sign up

Export Citation Format

Share Document