Excessive Derotational K-Wire Angulation Decreases Compression by Headless Compression Screw

Author(s):  
Joseph A. Gil ◽  
Michael D. Montague ◽  
Christopher J. Lama ◽  
Peter Brodeur ◽  
Julia A. Katarincic ◽  
...  

Abstract Background Scaphoid fracture is the most common carpal bone fracture. Open reduction internal fixation of scaphoid fractures typically undergo stabilization by a single headless compression screw (HCS). During screw insertion, a derotational Kirschner wire (K-wire) is often placed for rotational control of the near and far fragment. Questions/purposes The aim of this study was to determine if there is an angle of derotational K-wire placement in relation to the axis of a HCS that compromises the amount of compression generated at a fracture site by the HCS. We hypothesize that increased off-axis angle will lead to decreased compression across the fracture site. Methods A Cellular Block 20 rigid polyurethane foam (Sawbones, Vashon, WA) scaphoid model was created to eliminate variability in bone mineral density in cadaveric bone. MiniAcutrak HCS screws (Acumed, Hillsboro, OR) were used for testing. Three conditions were tested: (1) HCS with derotational wire inserted parallel to the HCS (zero degrees off-axis); (2) HCS with derotational wire inserted 10 degrees off-axis; and (3) HCS with derotational wire inserted 20 degrees off-axis. Results A statistically significant difference in the mean compression of the control group (56.9 N) was found between the mean compression with the derotational K-wire placed 20 degrees off-axis (15.2 N) (p = 0.001). Conclusions Compression at the fracture site could be impeded by placing an excessively angulated off-axis derotation wire prior to insertion of the HCS. Clinical Relevance Our study adds a new detail to the optimal technique of HCS placement in scaphoid fractures to improve compression and fracture union.

2019 ◽  
Vol 08 (05) ◽  
pp. 360-365 ◽  
Author(s):  
Samik Patel ◽  
Juan Giugale ◽  
Nathan Tiedeken ◽  
Richard E. Debski ◽  
John R. Fowler

Background Proximal scaphoid fractures display high nonunion rates and increased revision cases. Waist fracture fixation involves maximizing screw length within the cortex; however, the optimal screw length for proximal scaphoid fractures remains unknown. Purpose The main purpose of this article is to compare stiffness and ultimate load for proximal scaphoid fracture fixation of various headless compression screw lengths. Methods Eighteen scaphoids underwent an osteotomy simulating a 7 mm oblique proximal fracture. Screws of three lengths (10, 18, and 24 mm) were randomly assigned for fixation. Each specimen underwent cyclic loading with stiffness calculated during the last loading cycle. Specimens that withstood cyclic loading were loaded to failure. Results No significant difference in stiffness between screw lengths was found. Ultimate load was significantly impacted by the screw length. A significant difference in ultimate load between a 10 and 24 mm screw was found; however, no significant difference occurred in ultimate load between an 18 and 24 mm screw. Conclusions No significant difference in stiffness between all groups could be due to similarities in purchase in the proximal aspect. The 10 mm screw withstanding less ultimate load compared to the 24 mm screw could be due to the 10 mm screw gaining less purchase on either side of the fracture site compared to the 24 mm screw. Lack of significant difference in ultimate load between the 18 and 24 mm screw could be occurring because the fracture site is closer to the 18 mm screw midpoint, as distal threads are engaged closer to the fracture. Clinical Relevance Maximizing screw length may not provide superior fixation biomechanically compared with fixation utilizing a 6 mm shorter screw for proximal scaphoid fractures.


2019 ◽  
Vol 05 (01) ◽  
pp. e1-e4 ◽  
Author(s):  
Ganesan Ganesan ◽  
Phagal Vijayaraghavan

Context Osteoporosis is a silent disease until it is complicated by trivial fall fractures. There is an increasing interest within the orthopaedic community in the noninvasive cost-effective measurement of the bone mineral density. Aims The aim of the study is to assess whether urinary N-telopeptide level can be a new diagnostic tool in diagnosing osteoporosis. Methods and Material This prospective study was done at Sri Ramachandra Medical Centre (SRMC) hospital from October 2015 to October 2017. The study was conducted among patients who comes to SRMC as inpatient or outpatient with suspected osteoporosis and underwent dual-energy X-ray absorptiometry (DXA) scan and urinary N-telopeptide. The inclusion criteria were women aged 65 or older, women aged less than 65 with risk factors, younger postmenopausal women with one or more risk factors, men aged 70 or older, men less than 70 with risk factors, and any above group patients who comes within 24 hours following trivial fall fractures. The exclusion criteria were pathological fracture, history of any illness affecting bone metabolism. The results from DXA scan were taken as gold standard against urinary N-telopeptide. Then the patients were divided into two groups control and study. The control group contains patients who had normal DXA, while study group contains patients having either osteopenia or osteoporosis. Based on our inclusion and exclusion criteria, 110 persons were included in the study. We had 60 study and 50 controls patients. We had 88 females and 22 males. The results obtained were statistically analyzed. Statistical Analysis Used The collected data were analyzed with IBM SPSS statistics software 23.0 version. To describe about the data descriptive statistics frequency analysis, percentage analysis was used for categorical variables and the mean and standard deviation were used for continuous variables. To find the significant difference between the bivariate samples in independent groups, the unpaired sample t-test was used. To find the significance in categorical data, chi-square test was used. In both the earlier statistical tools, the probability value of 0.05 is considered as significant level. Results In our study, we had 18.2% osteopenic and 36.4% osteoporotic patients. The mean value of urinary N-telopeptide in control was 49.8 and in case was 182.5. The standard deviation of urinary N-telopeptide value in case was 159.9. Conclusion Urinary N-telopeptide can give reproducible results and be able to assist in the evaluation of the quantity as well as the quality and be a good judge of someone's risk of fracture. Hence, urinary N-telopeptide can be used as a diagnostic tool for diagnosing osteoporosis.


Hand ◽  
2016 ◽  
Vol 12 (4) ◽  
pp. 362-368
Author(s):  
Andrew P. Matson ◽  
Ryan M. Garcia ◽  
Marc J. Richard ◽  
Fraser J. Leversedge ◽  
J. Mack Aldridge ◽  
...  

Background: Percutaneous techniques have been described for the treatment of nondisplaced scaphoid fractures, although less information has been reported about outcomes for unstable, displaced fractures. The aim of this study was to evaluate the union and complication rates following manual closed reduction and percutaneous screw placement for a consecutive series of unstable, displaced scaphoid fractures. Methods: A total of 28 patients (average age, 27 years; 22 male/6 female) were treated for isolated unstable displaced scaphoid waist fractures. Closed reduction and percutaneous headless, compression screw fixation was successfully performed in 14 patients (average age, 32 years; 10 male/4 female), and the remaining 14 patients required open reduction. Patients who underwent percutaneous treatment were followed for radiographic fracture union and clinical outcomes. Results: Thirteen of 14 fractures (93%) had clinical and radiographic evidence of bone union at an average of 2.8 months postoperatively. Average visual analog pain score at the time of union was 0.9. The average Quick Disability of the Arm, Shoulder, and Hand score at 2.5 years follow-up (range, 1.5-8.3 years) was 9.6 (range, 0.0-27.3). Complications included 1 case of nonunion and 1 case of intraoperative Kirschner wire breakage. Conclusions: Manual closed reduction followed by percutaneous headless, compression screw fixation was possible in 50% of patients who presented with acute unstable, displaced scaphoid fractures. This technique appears to be a safe and effective method when a manual reduction is possible, and it may offer a less invasive option when compared with a standard open technique.


2021 ◽  
Vol 80 (Suppl 1) ◽  
pp. 1266.1-1266
Author(s):  
A. Ajerouassi ◽  
K. Nassar ◽  
S. Janani

Background:Osteoporosis is common in spondyloarthritis, due to reduced spinal mobility, and inflammation. Anti-inflammatory treatments have a beneficial effect on the bone, and there is a significant increase in bone density during treatment with anti-TNF alpha.Objectives:to study bone mineral density in patients with ankylosing spondyloarthritis (AS) treated with anti-TNF alpha.Methods:This is a retrospective descriptive study of patients with AS meeting the modified New York criteria. Bone mineral density, assessed by dual energy x-ray absorptiometry (DXA), of AS patients treated with anti-TNF alpha was compared to that of a control group of AS patients not treated with anti-TNF alpha.Inclusion criteria:- Male patients- Patients who do not have an abnormality disrupting phosphocalcic and bone metabolism- For Patients on anti-TNF alpha: the treatment must be received for more than 6 monthsResults:A total of 22 patients were included, including 11 patients on anti-TNF alpha and 11 patients not on anti-TNF. The mean age (standard deviation) was 28 (± 7.2) years and 41 (± 14.8) in the cases and controls respectively. The mean body mass index in the AS group on anti-TNF was 22.16 kg / m2 and in the control group was 19.64 kg / m2. In the AS group on anti-TNF alpha, the mean bone mineral density of the spine was 1.092 g / cm2 (mean T score = -0.63) and that of the femoral neck, the mean bone mineral density was 0.888g / cm2 (mean T score = -1.04). In the control group, the mean bone mineral density of the spine was 0.959 g / cm2 (mean T score = -1.91) and the mean bone mineral density of the femoral neck was 0.774 g / cm2 (mean T score = -1.99). Bone mineral density in the spine and cervix was higher in the group receiving anti-TNF alpha (p = 0.09, p = 0.173 respectively)Conclusion:Our study shows the increase, although not statistically significant, in bone mineral density in AS patients receiving anti-TNF alpha agents compared to controls. Our results agree with those of the literature which support the bone protective effect of anti-TNF alpha. The non-significant difference can be explained by the delay in the introduction of biotherapy at the advanced stage of the structural evolution of AS. The best solution is to start TNF inhibitors at the early inflammatory stage of AS.Disclosure of Interests:None declared.


Author(s):  
Syoof Khowman Alramahy ◽  
Akram Hadi Hamza

This study was carried out to study of some immunological aspects among the pulmonary Tuberculosis patients infected with causative agent, Mycobacterium tuberculosis. A Total of 200 sputum samples were collected from patients attending the consultant Clinic for Chest and Respiratory disease center, Diwaniya. Control group (No=15) also included. According to acid fast stain of sputum, the patients were classified as positive (No=91,45.5%) and negative (No=109,54.5, Lowenstein Jensen medium used for the cultivation of samples, on which 70% of sputum samples where positive culture for this microorganism. The grown microorganism were identified as M. tuberculosis, based on positive A.F.B, Niacin producers ,negative for catlase at 68c. The mean IgG level was l184.053±76.684 mg/100 ml in tuberculosis group compared with 1016.533 ± 44.882 mg/100ml in control group, rendering the statistical difference significant. For IgA and IgM levels, they were at mean of 315.880±38.552 mg/100 ml and 119.527±8.464 mg/100 ml in control group compared with 396.358±38.776 mg/100 ml and 134.207±11.696 mg/100 ml in patients group respectively with significant difference


Hand ◽  
2021 ◽  
pp. 155894472097411
Author(s):  
Luke T. Nicholson ◽  
Kristen M. Sochol ◽  
Ali Azad ◽  
Ram Kiran Alluri ◽  
J. Ryan Hill ◽  
...  

Background: Management of scaphoid nonunions with bone loss varies substantially. Commonly, internal fixation consists of a single headless compression screw. Recently, some authors have reported on the theoretical benefits of dual-screw fixation. We hypothesized that using 2 headless compression screws would impart improved stiffness over a single-screw construct. Methods: Using a cadaveric model, we compared biomechanical characteristics of a single tapered 3.5- to 3.6-mm headless compression screw with 2 tapered 2.5- to 2.8-mm headless compression screws in a scaphoid waist nonunion model. The primary outcome measurement was construct stiffness. Secondary outcome measurements included load at 1 and 2 mm of displacement, load to failure for each specimen, and qualitative assessment of mode of failure. Results: Stiffness during load to failure was not significantly different between single- and double-screw configurations ( P = .8). Load to failure demonstrated no statistically significant difference between single- and double-screw configurations. Using a qualitative assessment, the double-screw construct maintained rotational stability more than the single-screw construct ( P = .029). Conclusions: Single- and double-screw fixation constructs in a cadaveric scaphoid nonunion model demonstrate similar construct stiffness, load to failure, and load to 1- and 2-mm displacement. Modes of failure may differ between constructs and represent an area for further study. The theoretical benefit of dual-screw fixation should be weighed against the morphologic limitations to placing 2 screws in a scaphoid nonunion.


2019 ◽  
Vol 12 (S 01) ◽  
pp. S39-S44
Author(s):  
Michael Okoli ◽  
Kevin Lutsky ◽  
Michael Rivlin ◽  
Brian Katt ◽  
Pedro Beredjiklian

Abstract Introduction The purpose of this study is to determine the radiographic dimensions of the finger metacarpals and to compare these measurements with headless compression screws commonly used for fracture fixation. Materials and Methods We analyzed computed tomography (CT) scans of the index, long, ring, and small metacarpal bones and measured the metacarpal length, distance from the isthmus to the metacarpal head, and intramedullary diameter of the isthmus. Metacarpals with previous fractures or hardware were excluded. We compared these dimensions with the size of several commercially available headless screws used for intramedullary fixation. Results A total of 223 metacarpals from 57 patients were analyzed. The index metacarpal was the longest, averaging 67.6 mm in length. The mean distance from the most distal aspect of the metacarpal head to the isthmus was 40.3, 39.5, 34.4, and 31 mm for the index, long, ring, and small metacarpals, respectively. The narrowest diameter of the isthmus was a mean of 2.6, 2.7, 2.3, and 3 mm for the index, long, ring, and small metacarpals, respectively. Of 33 commercially available screws, only 27% percent reached the isthmus of the index metacarpal followed by 42, 48, and 58% in the long, ring, and small metacarpals, respectively. Conclusion The index and long metacarpals are at a particular risk of screw mismatch given their relatively long lengths and narrow isthmus diameters.


2020 ◽  
Vol 79 (Suppl 1) ◽  
pp. 1188.1-1188
Author(s):  
C. Daldoul ◽  
N. El Amri ◽  
K. Baccouche ◽  
H. Zeglaoui ◽  
E. Bouajina

Background:Inflammatory bowel disease (IBD), including ulcerative colitis (UC) and Crohn’s disease (CD), is considered as a risk factor of low bone mineral density (BMD). In fact, the prevalence of osteoporosis ranges from 17% to 41% in IBD patients. The possible contributing factors may include malabsorption, glucocorticoid treatment and coexisting comorbiditiesObjectives:The purpose of our work was to determine the frequency and the determinants of osteoporosis in patients with IBD and to assess whether there is a difference in BMD status between UC and CD.Methods:This is a retrospective study, over a period of 5 years (from January 2014 to December 2018) and including patients followed for IBD who had a measurement of BMD by DEXA. Clinical, anthropometric and densitometric data (BMD at the femoral and vertebral site) were recorded. The WHO criteria for the definition of osteoporosis and osteopenia were applied.Results:One hundred and five patients were collected; among them 45 were men and 60 were women. The average age was 45.89 years old. The average body mass index (BMI) was 25.81 kg/m2 [16.44-44.15]. CD and UC were diagnosed in respectively 57.1% and 42.9%. A personal history of fragility fracture was noted in 4.8%. Hypothyroidism was associated in one case. Early menopause was recorded in 7.6%. 46.8% patients were treated with corticosteroids. The mean BMD at the vertebral site was 1.023 g/cm3 [0.569-1.489 g/cm3]. Mean BMD at the femoral site was 0.920g/cm3 [0.553-1.286g / cm3]. The mean T-score at the femoral site and the vertebral site were -1.04 SD and -1.27 SD, respectively. Osteoporosis was found in 25.7% and osteopenia in 37.1%. Osteoporosis among CD and UC patients was found in respectively 63% and 37%. The age of the osteoporotic patients was significantly higher compared to those who were not osteoporotic (52.23 vs 43.67 years, p = 0.01). We found a significantly higher percentage of osteoporosis among men compared to women (35.6% vs 18.3%, p=0.046). The BMI was significantly lower in the osteoporotic patients (23.87 vs 26.48 kg/m2, p=0.035) and we found a significant correlation between BMI and BMD at the femoral site (p=0.01). No increase in the frequency of osteoporosis was noted in patients treated with corticosteroids (27.9% vs 21.6%, p=0.479). Comparing the UC and CD patients, no difference was found in baseline characteristics, use of steroids or history of fracture. No statistically significant difference was found between UC and CD patients for osteoporosis(p=0.478), BMD at the femoral site (p=0.529) and at the vertebral site (p=0.568).Conclusion:Osteoporosis was found in 25.7% of IBD patients without any difference between CD and UC. This decline does not seem to be related to the treatment with corticosteroids but rather to the disease itself. Hence the interest of an early screening of this silent disease.Disclosure of Interests:None declared


2020 ◽  
pp. bmjstel-2020-000657
Author(s):  
Rebecca Singer ◽  
Grace Leo ◽  
Tessa Davis ◽  
Ben Lawton ◽  
Henry Goldstein ◽  
...  

Previous research has examined the utilisation of musical cues to improve the performance of cardiopulmonary resuscitation (CPR) delivered in training environments. We postulated a musical cue that is both contemporary and transcends cultures may improve CPR performance. Our aim was to establish whether chest compressions are performed with improved rate and depth if a song of a fixed beat (PinkFong’s ‘Baby Shark’ with a tempo of 115 beats per minute (bpm) and 15 beats in each verse) is played to a healthcare professional immediately before undertaking CPR compared to whale noises (a non-metronomic rhythm). 58 Participants of a paediatric conference (majority doctors) were randomly assigned to listen to a minute of Baby Shark (28) or whale song (30) and then undertake a minute of CPR. There was no significant difference in the mean compression rate between the Baby Shark and control groups, with the groups achieving 121 and 125 bpm, respectively (p=0.18). In relation to compression depth within the target zone, the Baby Shark group had more compressions completed within the target zone (55%) than the control group (39%) although this difference was not significant (p=0.08). Listening to Baby Shark prior to undertaking simulated CPR does not improve overall performance, but there is a potential tendency to improve adequate compression depth which may be beneficial in training exercises.


2021 ◽  
Vol 10 (12) ◽  
pp. 2637
Author(s):  
Mª. Ángeles del Buey-Sayas ◽  
Elena Lanchares-Sancho ◽  
Pilar Campins-Falcó ◽  
María Dolores Pinazo-Durán ◽  
Cristina Peris-Martínez

Purpose: To evaluate and compare corneal hysteresis (CH), corneal resistance factor (CRF), and central corneal thickness (CCT), measurements were taken between a healthy population (controls), patients diagnosed with glaucoma (DG), and glaucoma suspect patients due to ocular hypertension (OHT), family history of glaucoma (FHG), or glaucoma-like optic discs (GLD). Additionally, Goldmann-correlated intraocular pressure (IOPg) and corneal-compensated IOP (IOPcc) were compared between the different groups of patients. Methods: In this prospective analytical-observational study, a total of 1065 patients (one eye of each) were recruited to undergo Ocular Response Analyzer (ORA) testing, ultrasound pachymetry, and clinical examination. Corneal biomechanical parameters (CH, CRF), CCT, IOPg, and IOPcc were measured in the control group (n = 574) and the other groups: DG (n = 147), FHG (n = 78), GLD (n = 90), and OHT (n = 176). We performed a variance analysis (ANOVA) for all the dependent variables according to the different diagnostic categories with multiple comparisons to identify the differences between the diagnostic categories, deeming p < 0.05 as statistically significant. Results: The mean CH in the DG group (9.69 mmHg) was significantly lower compared to controls (10.75 mmHg; mean difference 1.05, p < 0.001), FHG (10.70 mmHg; mean difference 1.00, p < 0.05), GLD (10.63 mmHg; mean difference 0.93, p < 0.05) and OHT (10.54 mmHg; mean difference 0.84, p < 0.05). No glaucoma suspects (FHG, GLD, OHT groups) presented significant differences between themselves and the control group (p = 1.00). No statistically significant differences were found in the mean CRF between DG (11.18 mmHg) and the control group (10.75 mmHg; mean difference 0.42, p = 0.40). The FHG and OHT groups showed significantly higher mean CRF values (12.32 and 12.41 mmHg, respectively) than the DG group (11.18 mmHg), with mean differences of 1.13 (p < 0.05) and 1.22 (p < 0.001), respectively. No statistically significant differences were found in CCT in the analysis between DG (562 μ) and the other groups (control = 556 μ, FHG = 576 μ, GLD = 569 μ, OHT = 570 μ). The means of IOPg and IOPcc values were higher in the DG patient and suspect groups than in the control group, with statistically significant differences in all groups (p < 0.001). Conclusion: This study presents corneal biomechanical values (CH, CRF), CCT, IOPg, and IOPcc for diagnosed glaucoma patients, three suspected glaucoma groups, and a healthy population, using the ORA. Mean CH values were markedly lower in the DG group (diagnosed with glaucoma damage) compared to the other groups. No significant difference was found in CCT between the DG and control groups. Unexpectedly, CRF showed higher values in all groups than in the control group, but the difference was only statistically significant in the suspect groups (FHG, GLD, and OHT), not in the DG group.