scholarly journals Comparison of Hollow-Fiber Ultrafilters with Pleated Capsule Filters for Surface and Tap Water Samples Using U.S. EPA Method 1623

2012 ◽  
Vol 138 (8) ◽  
pp. 899-901 ◽  
Author(s):  
Gina H. Kimble ◽  
James E. Amburgey ◽  
Vincent R. Hill
2011 ◽  
Vol 77 (11) ◽  
pp. 3609-3616 ◽  
Author(s):  
Yaoyu Feng ◽  
Xukun Zhao ◽  
Jiaxu Chen ◽  
Wei Jin ◽  
Xiaonong Zhou ◽  
...  

ABSTRACTGenotyping studies on the source and human infection potential ofCryptosporidiumoocysts in water have been almost exclusively conducted in industrialized nations. In this study, 50 source water samples and 30 tap water samples were collected in Shanghai, China, and analyzed by the U.S. Environmental Protection Agency (EPA) Method 1623. To find a cost-effective method to replace the filtration procedure, the water samples were also concentrated by calcium carbonate flocculation (CCF). Of the 50 source water samples, 32% were positive forCryptosporidiumand 18% forGiardiaby Method 1623, whereas 22% were positive forCryptosporidiumand 10% forGiardiaby microscopy of CCF concentrates. When CCF was combined with PCR for detection, the occurrence ofCryptosporidium(28%) was similar to that obtained by Method 1623. Genotyping ofCryptosporidiumin 17 water samples identified the presence ofC. andersoniin 14 water samples,C. suisin 7 water samples,C. baileyiin 2 water samples,C. meleagridisin 1 water sample, andC. hominisin 1 water sample. Therefore, farm animals, especially cattle and pigs, were the major sources of water contamination in Shanghai source water, and most oocysts found in source water in the area were not infectious to humans.Cryptosporidiumoocysts were found in 2 of 30 tap water samples. The combined use of CCF for concentration and PCR for detection and genotyping provides a less expensive alternative to filtration and fluorescence microscopy for accurate assessment ofCryptosporidiumcontamination in water, although the results from this method are semiquantitative.


2009 ◽  
Vol 75 (16) ◽  
pp. 5284-5289 ◽  
Author(s):  
Carmela M. Smith ◽  
Vincent R. Hill

ABSTRACT Dead-end ultrafiltration (DEUF) is an alternative approach to tangential-flow hollow-fiber ultrafiltration that can be readily employed under field conditions to recover microbes from water. The hydraulics of DEUF and microbe recovery for a new DEUF method were investigated using 100-liter tap water samples. Pressure, flow rate, and temperature were investigated using four hollow-fiber ultrafilter types. Based on hydraulic performance, the Asahi Kasei REXEED 25S ultrafilter was selected for microbe recovery experiments. Microbe recovery experiments were performed using MS2 bacteriophage, Enterococcus faecalis, Clostridium perfringens spores, and Cryptosporidium parvum oocysts. Microbes were recovered from ultrafilters by backflushing using a surfactant solution. Average flow rates were 2.1 liters/min for 100-liter water samples having turbidities of 0.28 to 4.3 nephelometric turbidity units (NTU), and no evidence of appreciable filter clogging was observed. The DEUF average recovery efficiencies for each study analyte in tap water were as follows: for E. faecalis, 93% ± 16%; for MS2, 57% ± 7.7%; for C. perfringens spores, 94% ± 22%; and for C. parvum, 87% ± 18%. Average microbe recoveries for tap water amended with surface water (average turbidity = 4.3 NTU) were as follows: for E. faecalis, 78% ± 12%; for MS2, 73% ± 13%; for C. perfringens, 57% ± 21%; and for C. parvum, 83% ± 21%. These data demonstrate that DEUF is an effective method for recovering diverse microbes from water and should be a useful tool for field-based environmental investigations.


Author(s):  
Ahmad Z Al-Herrawy ◽  
Mohamed A Marouf ◽  
Mahmoud A. Gad

Genus Acanthamoeba causes 3 clinical syndromes amebic keratitis, granulomatous amebic encephalitis and disseminated granulomatous amebic disease (eg, sinus, skin and pulmonary infections). A total of 144 tap water samples were collected from Giza governorate, Egypt. Samples were processed for detection of Acanthamoeba species using non-nutrient agar (NNA) and were incubated at 30oC. The isolates of Acanthamoeba were identified to species level based on the morphologic criteria. Molecular characterization of the Acanthamoeba isolates to genus level was performed by using PCR. The obtained results showed that the highest occurrence percentage of Acanthamoeba species in water samples was observed in summer season (38.9%), then it decreased to be 30.6% in spring and 25% in each of autumn and winter. PCR analysis showed that 100% of 43 Acanthamoeba morphologically positive samples were positive by genus specific primer. In the present study eight species of Acanthamoeba can be morphologically recognized namely Acanthamoeba triangularis, Acanthamoeba echinulata, Acanthamoeba astronyxis, Acanthamoeba comandoni, Acanthamoeba griffini, Acanthamoeba culbertsoni, Acanthamoeba quina and Acanthamoeba lenticulata. In conclusion, the most common Acanthamoeba species in tap water was Acanthamoeba comandoni


Author(s):  
V.V. Lapenko ◽  
L.N. Bikbulatova ◽  
E.M. Ternikova

Water is very important for humans, as it is a solvent for metabolic products. Moreover, it is necessary for metabolism, biochemical and transport processes. The elemental status in persons depends on the geochemical environment and consumption of bioelements with food and water. The aim of the paper is to conduct a comprehensive assessment of chemical composition of drinking tap water in Khanty-Mansiysk and Salekhard. Materials and Methods. The chemical composition of 100 samples of drinking tap water was analyzed by atomic absorption spectrometry, spectrophotometry and capillary electrophoresis. All in all, there were 50 samples from Khanty-Mansiysk and 50 samples from Salekhard. The results were compared with Sanitary Rules and Norms 2.1.4.1074-01. Results. Drinking tap water in Salekhard contains a significantly higher concentration of iron, which is much above the maximum allowable concentration, if compared to water samples in Khanty-Mansiysk (p=0.03). In the cities under consideration, the water undergoes high-quality reagent-free treatment. However, the deterioration of the water supply networks in Salekhard is 3 times as high as in Khanty-Mansiysk. Calcium and magnesium concentration in water samples from Khanty-Mansiysk is 5.6 and 3.9 times lower than the MAC; in water samples from Salekhard calcium concentration is 6.3 (p=0.008) and magnesium concentration 4.6 (p<0.001) times lower than the MAC. Conclusion. The consumption of ultra-fresh drinking water leads to low intake of bioelements, which are a part of enzymes contributing to the human antioxidant defense and can result in manifestation of cardiovascular diseases. This is especially true for Salekhard with very soft drinking water and high iron concentration, which excess can exhibit prooxidant properties. Keywords: tap water, bioelements, northern region, antioxidants. Вода является важнейшим соединением для человека: необходима в качестве растворителя продуктов метаболизма и протекания обменных, биохимических и транспортных процессов. Элементный статус организма человека зависит от геохимического окружения и поступления биоэлементов с пищей и водой. Цель. Провести комплексную оценку химического состава водопроводной воды городов Ханты-Мансийск и Салехард. Материалы и методы. Методами атомно-абсорбционной спектрометрии, спектрофотометрии и капиллярного электрофореза проанализирован химический состав 100 проб водопроводной воды: по 50 из Ханты-Мансийска и Салехарда. Результаты сравнивали с СанПиН 2.1.4.1074-01. Результаты. В водопроводной воде Салехарда установлена превышающая ПДК и достоверно более высокая концентрация железа сравнительно с водой Ханты-Мансийска (р=0,03). При условии качественной безреагентной водоподготовки в изучаемых городах это обусловлено изношенностью водопроводных сетей в Салехарде, более чем в 3 раза превышающей этот показатель в Ханты-Мансийске. Концентрация кальция и магния в воде Ханты-Мансийска в 5,6 и 3,9 раза ниже ПДК; в воде Салехарда – в 6,3 (р=0,008) и 4,6 (р<0,001) раза ниже ПДК соответственно. Заключение. Употребление ультрапресной питьевой воды на фоне очень малого поступления с водой биоэлементов, входящих в состав ферментов антиоксидантной защиты организма человека, может привести к манифестации кардиоваскулярных заболеваний. Это особенно актуально для г. Салехарда с очень мягкой питьевой водой с повышенным содержанием железа, избыток которого может проявлять прооксидантные свойства. Ключевые слова: водопроводная вода, биоэлементы, северный регион, антиоксиданты.


1982 ◽  
Vol 14 (4-5) ◽  
pp. 257-272 ◽  
Author(s):  
G Belfort ◽  
A Paluszek ◽  
L S Sturman

The Automated Hollow Fiber Ultrafiltration (AHFU) method is proposed here as a simple, efficient and rapid virus concentration technique from tap and drinking water sources. The results reported here extend the testing of the AHFU method to include two Picornaviruses [Poliovirus 2 (vaccine) and Echovirus 1] and Reovirus 3. Their respective mean virus recoveries from between 3 and 100 l of tap water is 88 ± 26, 79 ± 60, and 104 ± 48%. Various approaches including membrane surface modification, changes in backwash hydrodynamics, modification of the feed and backwash composition, and the use of S35-methionine labelled Poliovirus 2, are used to study the recovery of sorbed Poliovirus 2 from the hollow fiber/solution interface. An increase in the backwash pH to between 9.5 and 10.5 significantly improved Poliovirus 2 recovery. This, together with the labelled experiments, indicates that the virus-membrane interactions are probably electrostatic in nature. Convective polarization during filtration probably brings the virus close enough to the surface for these interactions to occur since virus losses were not detected for a non-permeation recycle experiment. Because very low Reynold's numbers are used, the flow is in the creeping-flow-regime for both filtration and backwashing (axial and radial). Unless significantly higher Reynolds could be used, enhanced recovery due to purely hydrodynamic forces is unlikely. High Reynold's numbers, of course, are limited by the pressure constraints of the hollow fibers.


2019 ◽  
Vol 42 (14) ◽  
pp. 2398-2406 ◽  
Author(s):  
Xiangping Ji ◽  
Min Sun ◽  
Chunying Li ◽  
Sen Han ◽  
Xiuqin Wang ◽  
...  

2021 ◽  
Vol 44 (1) ◽  
pp. 194-202
Author(s):  
Funda Demir ◽  
Meral Yildirim Ozen ◽  
Emek Moroydor Derun

Abstract In this study, essential (Ca, Cr, Cu, Fe, K, Mg, Na, P, Zn), and non-essential (Al, Ni, Pb) element contents of the drinking and baby water samples which are sold in the local market and tap water samples in Istanbul were examined. It was determined that elements of Cr, Cu, Fe, P, Zn, Al, and Ni were below detection limits in all water samples. Among the non-essential elements analyzed in water samples, Pb was the only detected element. At the same time, the percentages that meet the daily element requirements of infants were also calculated. As a result of the evaluations made, there is no significant difference in infant nutrition between baby waters and other drinking waters in terms of the element content.


Radiocarbon ◽  
2014 ◽  
Vol 56 (3) ◽  
pp. 1107-1114 ◽  
Author(s):  
Zhongtang Wang ◽  
Dan Hu ◽  
Hong Xu ◽  
Qiuju Guo

Atmospheric CO2 and aquatic water samples were analyzed to evaluate the environmental 14C enrichment due to operation of the Qinshan nuclear power plant (NPP), where two heavy-water reactors and five pressurized-water reactors are employed. Elevated 14C-specific activities (2–26.7 Bq/kg C) were observed in the short-term air samples collected within a 5-km radius, while samples over 5 km were close to background levels. The 14C-specific activities of dissolved inorganic carbon (DIC) in the surface seawater samples ranged from 196.8 to 206.5 Bq/kg C (average 203.4 Bq/kg C), which are close to the background value. No elevated 14C level in surface seawater was found after 20 years of operation of Qinshan NPP, indicating that the 14C discharged was well diffused. The results of the freshwater samples show that excess 14C-specific activity (average 17.1 Bq/kg C) was found in surface water and well water samples, while no obvious 14C increase was found in drinking water (groundwater and tap water) compared to the background level.


2021 ◽  
Vol 19 (11) ◽  
pp. 22-31
Author(s):  
Sawsan Sh. Fleifil ◽  
Zahraa A. Ismail AL-Sudani

In this study, assessment of levels natural radioactivity in drinking water samples of Misan Province of Iraq was carried out. A total of 33 (Tigris river, station and Tap) water samples collected from eleven places in Misan Province of Iraq. The beta and alpha gross radioactivity of the samples water was measured and an average annual effective dose derived of drinking-water ingestion was estimation utilizing new model a LB-4110 low background gas flow proportional counter. The data indicated that the Beta and Alpha gross activities and annual effective dose in samples did not exceed WHO recommended levels (0.5 Bq/L of Alpha gross, 1.0 Bq/L of Beta gross and 0.1 mSv/y for annual effective dose).