Integration of vis-NIR and pXRF spectroscopy for rapid measurement of soil lead concentrations

Soil Research ◽  
2020 ◽  
Vol 58 (3) ◽  
pp. 247 ◽  
Author(s):  
L. E. Pozza ◽  
T. F. A. Bishop ◽  
U. Stockmann ◽  
G. F. Birch

Heavy metals accumulate in soil over time and, with changing land use, humans may be exposed to elevated contaminant concentrations. It is therefore important to delineate contaminated sites in the most efficient and accurate manner. Sensors, such as portable X-ray fluorescence (pXRF) and visible near-infrared (vis-NIR) spectroscopy predict metal concentrations more rapidly and in a less hazardous manner compared to traditional laboratory analytical methods. The current study explored the potential for integrating vis-NIR and pXRF outputs to improve lead predictions in fine- (<62.5 µm) and whole-fraction (<2 mm) soil samples. A multi-stage approach was taken to compare different data treatments and combination methods for the prediction of whole-fraction lead content. Data treatment included principal component analysis, and combination methods included concatenation of pXRF and vis-NIR spectra before modelling, and Granger–Ramanathan model averaging of pXRF and vis-NIR model outputs. The most accurate predictions of whole-fraction lead were obtained by Granger–Ramanathan model averaging of vis-NIR Cubist predictions and Compton-normalised pXRF output: Lin’s Concordance Correlation Coefficient (LCCC) = 0.95, root mean square error (RMSE) = 86.4 mg kg–1, Bias < 0.001 mg kg–1 and ratio of performance to inter-quartile range (RPIQ) = 0.37. The most suitable modelling method was then used to predict fine-fraction lead, which provided a similarly accurate model fit (LCCC = 0.94, RMSE = 84.2 mg kg–1, Bias < 0.001 mg kg–1 and RPIQ = 0.34), indicating the potential to reduce the number of samples required for fine-fraction processing. In addition, the quality of the prediction interval estimates was examined – an important aspect in modelling which is underutilised in current literature related to soil spectroscopy.

Author(s):  
Krzysztof Wójcicki

The objective of the research study was to apply near infrared (NIR) spectroscopy to evaluate the quality of protein supplements available in the Polish shops and gyms. The evaluation was performed on the basis of the determination of the protein quantity contained in the individual samples by a Kjeldahl method and then the evaluation results were correlated with the measured NIR spectra using an appropriate chemometric method. The research material consisted of fifteen protein supplement samples for athletes, which included the following types: WPI (protein isolate), WPC (protein concentrate), WPH (protein hydrolysate), and mixtures thereof. The obtained NIR spectra of protein supplements were characterized by a similar shape of the bands. Depending on the type of protein, a different intensity of absorption of individual bands could be observed. A Principal Component Analysis (PCA) was used to distinguish the samples based on the spectra measured. Unfortunately, owing to the varying composition of the protein mixtures, it was not possible to find characteristic arrangement of the samples depending on their types. The spectra were correlated with the protein contents determined in the samples using a Partial Least Squares regression method (PLS regression) and various mathematic transformations of the NIR spectral data. The obtained regression models were analysed and the analysis results confirmed that it was possible to apply NIR spectra to estimate the content of proteins in protein supplements. The best result was obtained in a spectrum region between 9401 and 5448 cm-1 and after the first derivative was applied with Multiplicate Scatter Correction (MSC) as a mathematical pre-treatment. On the basis of the results obtained, it was proved that the NIR spectra applied together with the chemometric analysis could be used to quickly evaluate the products studied.


Author(s):  
Nawaf Abu-Khalaf

Quality of agricultural products is a very important issue for consumers as well as for farmers in relation to price, health and flavour. One of the factors that determine the quality is the absence of pathogens that can cause diseases for products and also for consumers. An advanced method to sense pathogens and their antagonists is the use of Visible/Near Infrared (VIS/NIR) spectroscopy. In this paper, the VIS/NIR spectroscopy, with the help of two techniques of multivariate data analysis (MVDA); namely principal component analysis (PCA) and support vector machine (SVM)-classification; showed very reliable results for sensing two artificially inoculated fungi (Fusarium oxysporum f. sp. Lycopersici and Rhizoctonia solani), and two antagonistic bacteria (Bacillus atrophaeus and Pseudomonas aeruginosa). The two fungi cause loss of quality and quantity for tomatoes. The results showed that the lowest classification rates using VIS/NIR spectroscopy for pathogens, antagonistic and their combinations were 90%, 85% and 74%, respectively. These results open a wide range for using VIS/NIR spectroscopy sensor technology for agricultural commodities quality at quality control checkpoints.


2015 ◽  
Vol 3 (1) ◽  
pp. 12-22
Author(s):  
Nawaf Abu-Khalaf

Quality of agricultural products is a very important issue for consumers as well as for farmers in relation to price, health and flavour. One of the factors that determine the quality is the absence of pathogens that can cause diseases for products and also for consumers. An advanced method to sense pathogens and their antagonists is the use of Visible/Near Infrared (VIS/NIR) spectroscopy. In this paper, the VIS/NIR spectroscopy, with the help of two techniques of multivariate data analysis (MVDA); namely principal component analysis (PCA) and support vector machine (SVM)-classification; showed very reliable results for sensing two artificially inoculated fungi (Fusarium oxysporum f. sp. Lycopersici and Rhizoctonia solani), and two antagonistic bacteria (Bacillus atrophaeus and Pseudomonas aeruginosa). The two fungi cause loss of quality and quantity for tomatoes. The results showed that the lowest classification rates using VIS/NIR spectroscopy for pathogens, antagonistic and their combinations were 90%, 85% and 74%, respectively. These results open a wide range for using VIS/NIR spectroscopy sensor technology for agricultural commodities quality at quality control checkpoints.


Recycling ◽  
2021 ◽  
Vol 6 (1) ◽  
pp. 11
Author(s):  
Kirsti Cura ◽  
Niko Rintala ◽  
Taina Kamppuri ◽  
Eetta Saarimäki ◽  
Pirjo Heikkilä

In order to add value to recycled textile material and to guarantee that the input material for recycling processes is of adequate quality, it is essential to be able to accurately recognise and sort items according to their material content. Therefore, there is a need for an economically viable and effective way to recognise and sort textile materials. Automated recognition and sorting lines provide a method for ensuring better quality of the fractions being recycled and thus enhance the availability of such fractions for recycling. The aim of this study was to deepen the understanding of NIR spectroscopy technology in the recognition of textile materials by studying the effects of structural fabric properties on the recognition. The identified properties of fabrics that led non-matching recognition were coating and finishing that lead different recognition of the material depending on the side facing the NIR analyser. In addition, very thin fabrics allowed NIRS to penetrate through the fabric and resulted in the non-matching recognition. Additionally, ageing was found to cause such chemical changes, especially in the spectra of cotton, that hampered the recognition.


2020 ◽  
Vol 13 (1) ◽  
Author(s):  
Elise A. Kho ◽  
Jill N. Fernandes ◽  
Andrew C. Kotze ◽  
Glen P. Fox ◽  
Maggy T. Sikulu-Lord ◽  
...  

Abstract Background Existing diagnostic methods for the parasitic gastrointestinal nematode, Haemonchus contortus, are time consuming and require specialised expertise, limiting their utility in the field. A practical, on-farm diagnostic tool could facilitate timely treatment decisions, thereby preventing losses in production and flock welfare. We previously demonstrated the ability of visible–near-infrared (Vis–NIR) spectroscopy to detect and quantify blood in sheep faeces with high accuracy. Here we report our investigation of whether variation in sheep type and environment affect the prediction accuracy of Vis–NIR spectroscopy in quantifying blood in faeces. Methods Visible–NIR spectra were obtained from worm-free sheep faeces collected from different environments and sheep types in South Australia (SA) and New South Wales, Australia and spiked with various sheep blood concentrations. Spectra were analysed using principal component analysis (PCA), and calibration models were built around the haemoglobin (Hb) wavelength region (387–609 nm) using partial least squares regression. Models were used to predict Hb concentrations in spiked faeces from SA and naturally infected sheep faeces from Queensland (QLD). Samples from QLD were quantified using Hemastix® test strip and FAMACHA© diagnostic test scores. Results Principal component analysis showed that location, class of sheep and pooled versus individual samples were factors affecting the Hb predictions. The models successfully differentiated ‘healthy’ SA samples from those requiring anthelmintic treatment with moderate to good prediction accuracy (sensitivity 57–94%, specificity 44–79%). The models were not predictive for blood in the naturally infected QLD samples, which may be due in part to variability of faecal background and blood chemistry between samples, or the difference in validation methods used for blood quantification. PCA of the QLD samples, however, identified a difference between samples containing high and low quantities of blood. Conclusion This study demonstrates the potential of Vis–NIR spectroscopy for estimating blood concentration in faeces from various types of sheep and environmental backgrounds. However, the calibration models developed here did not capture sufficient environmental variation to accurately predict Hb in faeces collected from environments different to those used in the calibration model. Consequently, it will be necessary to establish models that incorporate samples that are more representative of areas where H. contortus is endemic.


2015 ◽  
Vol 2015 ◽  
pp. 1-8 ◽  
Author(s):  
Hui Chen ◽  
Zan Lin ◽  
Chao Tan

Near-infrared (NIR) spectroscopy technique offers many potential advantages as tool for biomedical analysis since it enables the subtle biochemical signatures related to pathology to be detected and extracted. In conjunction with advanced chemometrics, NIR spectroscopy opens the possibility of their use in cancer diagnosis. The study focuses on the application of near-infrared (NIR) spectroscopy and classification models for discriminating colorectal cancer. A total of 107 surgical specimens and a corresponding NIR diffuse reflection spectral dataset were prepared. Three preprocessing methods were attempted and least-squares support vector machine (LS-SVM) was used to build a classification model. The hybrid preprocessing of first derivative and principal component analysis (PCA) resulted in the best LS-SVM model with the sensitivity and specificity of 0.96 and 0.96 for the training and 0.94 and 0.96 for test sets, respectively. The similarity performance on both subsets indicated that overfitting did not occur, assuring the robustness and reliability of the developed LS-SVM model. The area of receiver operating characteristic (ROC) curve was 0.99, demonstrating once again the high prediction power of the model. The result confirms the applicability of the combination of NIR spectroscopy, LS-SVM, PCA, and first derivative preprocessing for cancer diagnosis.


2021 ◽  
pp. 096703352098731
Author(s):  
Adenilton C da Silva ◽  
Lívia PD Ribeiro ◽  
Ruth MB Vidal ◽  
Wladiana O Matos ◽  
Gisele S Lopes

The use of alcohol-based hand sanitizers is recommended as one of several strategies to minimize contamination and spread of the COVID-19 disease. Current reports suggest that the virucidal potential of ethanol occurs at concentrations close to 70%. Traditional methods of verifying the ethanol concentration in such products invite potential errors due to the viscosity of chemical components or may be prohibitively expensive to undertake in large demand. Near infrared (NIR) spectroscopy and chemometrics have already been used for the determination of ethanol in other matrices and present an alternative fast and reliable approach to quality control of alcohol-based hand sanitizers. In this study, a portable NIR spectrometer combined with classification chemometric tools, i.e., partial least square discriminant analysis (PLS–DA) and linear discriminant analysis with successive algorithm projection (SPA–LDA) were used to construct models to identify conforming and non-conforming commercial and laboratory synthesized hand sanitizer samples. Principal component analysis (PCA) was applied in an exploratory data study. Three principal components accounted for 99% of data variance and demonstrate clustering of conforming and non-conforming samples. The PLS–DA and SPA–LDA classification models presented 77 and 100% of accuracy in cross/internal validation respectively and 100% of accuracy in the classification of test samples. A total of 43% commercial samples evaluated using the PLS–DA and SPA–LDA presented ethanol content non-conforming for hand sanitizer gel. These results indicate that use of NIR spectroscopy and chemometrics is a promising strategy, yielding a method that is fast, portable, and reliable for discrimination of alcohol-based hand sanitizers with respect to conforming and non-conforming ethanol concentrations.


2018 ◽  
Vol 10 (4) ◽  
pp. 351
Author(s):  
João S. Panero ◽  
Henrique E. B. da Silva ◽  
Pedro S. Panero ◽  
Oscar J. Smiderle ◽  
Francisco S. Panero ◽  
...  

Near Infrared (NIR) Spectroscopy technique combined with chemometrics methods were used to group and identify samples of different soy cultivars. Spectral data, collected in the range of 714 to 2500 nm (14000 to 4000 cm-1), were obtained from whole grains of four different soybean cultivars and were submitted to different types of pre-treatments. Chemometrics algorithms were applied to extract relevant information from the spectral data, to remove the anomalous samples and to group the samples. The best results were obtained considering the spectral range from 1900.6 to 2187.7 nm (5261.4 cm-1 to 4570.9 cm-1) and with spectral treatment using Multiplicative Signal Correction (MSC) + Baseline Correct (linear fit), what made it possible to the exploratory techniques Principal Component Analysis (PCA) and Hierarchical Cluster Analysis (HCA) to separate the cultivars. Thus, the results demonstrate that NIR spectroscopy allied with de chemometrics techniques can provide a rapid, nondestructive and reliable method to distinguish different cultivars of soybeans.


1996 ◽  
Vol 50 (12) ◽  
pp. 1541-1544 ◽  
Author(s):  
Hans-René Bjørsvik

A method of combining spectroscopy and multivariate data analysis for obtaining quantitative information on how a reaction proceeds is presented. The method is an approach for the explorative synthetic organic laboratory rather than the analytical chemistry laboratory. The method implements near-infrared spectroscopy with an optical fiber transreflectance probe as instrumentation. The data analysis consists of decomposition of the spectral data, which are recorded during the course of a reaction by using principal component analysis to obtain latent variables, scores, and loading. From the scores and the corresponding reaction time, it is possible to obtain a reaction profile. This reaction profile can easily be recalculated to obtain the concentration profile over time. This calculation is based on only two quantitative measurements, which can be (1) measurement from the work-up of the reaction or (2) chromatographic analysis from two withdrawn samples during the reaction. The method is applied to the synthesis of 3-amino-propan-1,2-diol.


2022 ◽  
pp. 096703352110572
Author(s):  
Nicholas T Anderson ◽  
Kerry B Walsh

Short wave near infrared (NIR) spectroscopy operated in a partial or full transmission geometry and a point spectroscopy mode has been increasingly adopted for evaluation of quality of intact fruit, both on-tree and on-packing lines. The evolution in hardware has been paralleled by an evolution in the modelling techniques employed. This review documents the range of spectral pre-treatments and modelling techniques employed for this application. Over the last three decades, there has been a shift from use of multiple linear regression to partial least squares regression. Attention to model robustness across seasons and instruments has driven a shift to machine learning methods such as artificial neural networks and deep learning in recent years, with this shift enabled by the availability of large and diverse training and test sets.


Sign in / Sign up

Export Citation Format

Share Document