scholarly journals Study on Workability High Strength Concrete Containing Pineapple Leaf Fiber (PALF)

2021 ◽  
Vol 1200 (1) ◽  
pp. 012006
Author(s):  
J. Hadipramana ◽  
F. V. Riza ◽  
T. Amirsyah ◽  
S.N. Mokhatar ◽  
M. Ardiansyah

Abstract The addition of fibers in concrete increases bridging force in interfacial transition zones inside the concrete matrix. Pineapple Leaf Fiber (PALF) is a natural fiber that has the potential to replace artificial fibers as reinforcement on concrete. As reinforcement fiber in concrete, PALF will undergo fibrillation and water absorption in concrete mixture and will change the mechanical properties of fresh concrete. So, the purpose of this study is to study the workability characteristics of fresh state concrete given PALF. Some variations of PALF composition are 0.04, 0.09, and 0.15 % wt. of cement is mixed into fresh concrete mixture with water-cement (w/c) ratio variations of 0.35, 0.38, and 0.41. The planned concrete is high-strength concrete, then the provisions of determination of coarse and fine aggregates using sieve analysis according to high-strength concrete material standards and concrete mixtures are given superplasticizer 0.09% wt. of cement constantly for all mixtures. A slump test method is still an option in this study, where this method becomes the standard to determine workability effectively. The results showed that an increase in concrete strength was achieved in the addition of PALF composition in concrete compared to control (normal concrete), in addition to the tendency of the relationship between w/c ratio, slump value, and compressive strength in all PALF variations achieved in this study.

2020 ◽  
Vol 10 (2) ◽  
pp. 642 ◽  
Author(s):  
Luís Bernardo ◽  
Sérgio Lopes ◽  
Mafalda Teixeira

This article describes an experimental program developed to study the influence of longitudinal prestress on the behaviour of high-strength concrete hollow beams under pure torsion. The pre-cracking, the post-cracking and the ultimate behaviour are analysed. Three tests were carried out on large hollow high-strength concrete beams with similar concrete strength. The variable studied was the level of longitudinal uniform prestress. Some important conclusions on different aspects of the beams’ behaviour are presented. These conclusions, considered important for the design of box bridges, include the influence of the level of prestress in the cracking and ultimate behaviour.


2002 ◽  
Vol 29 (2) ◽  
pp. 191-200 ◽  
Author(s):  
M Alavi-Fard ◽  
H Marzouk

Structures located in seismic zones require significant ductility. It is necessary to examine the bond slip characteristics of high strength concrete under cyclic loading. The cyclic bond of high strength concrete is investigated under different parameters, including load history, confining reinforcement, bar diameter, concrete strength, and the rate of pull out. The bond strength, cracking, and deformation are highly dependent on the bond slip behavior between the rebar and the concrete under cyclic loading. The results of cyclic testing indicate that an increase in cyclic displacement will lead to more severe bond damage. The slope of the bond stress – displacement curve can describe the influence of the rate of loading on the bond strength in a cyclic test. Specimens with steel confinement sustained a greater number of cycles than the specimens without steel confinement. It has been found that the maximum bond strength increases with an increase in concrete strength. Cyclic loading does not affect the bond strength of high strength concrete as long as the cyclic slip is less than the maximum slip for monotonic loading. The behavior of high strength concrete under a cyclic load is slightly different from that of normal strength concrete.Key words: bond, high strength, cyclic loading, bar spacing, loading rate, failure mechanism.


2021 ◽  
Vol 2021 ◽  
pp. 1-10
Author(s):  
Iswarya Gowram ◽  
Beulah M ◽  
MR Sudhir ◽  
Mothi Krishna Mohan ◽  
Deekshith Jain

Urbanization and industrialization have dramatically increased the manufacture of cement causing substantial pollution of the environment. The primary global concern related to cement manufacture has been the management of the large carbon footprints. The usages of environmentally friendly cementitious materials in the construction of structures have proved to be a viable option to deal with this environmental concern. Therefore, it is necessary to further explore the usage of cementitious materials which can replace cement albeit partially. In this direction of research, two such cementitious materials, namely, natural zeolite and metakaolin have been investigated in this study. High-strength concrete M60 with natural zeolite and metakaolin as the partial replacements for the cement has been prepared in this work. Polycarboxylic ether-based superplasticizer solution has been used to enhance workability. The test specimen cast and cured for 3, 7, 28, 60, and 90 days at ambient room temperature has been tested for compressive strength, split tensile strength, and flexural strength as per the Indian standards. The optimum mix of high-strength concrete thus manufactured has met the Indian standards, and the combination of cement +5% natural zeolite +10% metakaolin has exhibited the highest compressive, split tensile, and flexural strengths at 90 days of curing. Natural zeolite and metakaolin when used in smaller proportions have increased the concrete strength, and these materials are recommended for partial replacement of cement.


2015 ◽  
Vol 2015 ◽  
pp. 1-13 ◽  
Author(s):  
Lei Zeng ◽  
Zhenkun Cui ◽  
Yunfeng Xiao ◽  
Siqian Jin ◽  
Yuanyuan Wu

This paper presents an application of high strength concrete to concrete-encased composite frame building based on an experimental program. The work emphasized joints behavior under reverse cyclic loading caused by earthquakes to provide information for seismic design. To investigate the internal mechanisms and seismic performance, cyclic loading tests were carried out on five half-scale interior joints. Two design variables were addressed in the research: concrete strength and axial column load. Frame joints performance including crack pattern, failure mode, deformation, ductility, strain distribution, and energy dissipation capacity was investigated. It was found that all joint specimens behaved in a manner with joint panel shear failure. Using high strength concrete increased the joint strength and had relatively little effect on the stiffness and ductility. The axial column load helped the joint strength by better mobilizing the outer part of the joint, but it had an obvious influence on the ductility and energy-dissipating capacity, which can be improved by providing enough transverse reinforcement. A typical crack pattern was also provided which can well reflect mechanical character and damage process. This research should contribute to the future engineering applications of high strength concrete to concrete-encased composite structure.


2019 ◽  
Vol 140 ◽  
pp. 02017
Author(s):  
Anastasia Vasilenko ◽  
Dmitry Chernogorsky ◽  
Dmitry Strakhov ◽  
Leonid Sinyakov

The article is devoted to the analysis of technical and economic efficiency of application of high-strength concrete (HSC) in the eccentrically compressed columns. In the first part of the paper, the effect of concrete grade on in-creasing the column stiffness depending on steel ratio at different values of the relative eccentricity is considered. According to the results of the calculation, application of HSC is most effective at low values of the relative ec-centricity because increasing the concrete strength leads to more intensive increasing of column stiffness than increasing of steel ratio. In the second part of the paper, the material cost of the 1 linear meter of the column is calculated at the fixed value of column stiffness and application domain of HSC is defined in the case under consideration. In addition, load characteristics providing the efficiency of HSC application in the eccentrically compressed columns are determined.


2011 ◽  
Vol 71-78 ◽  
pp. 4203-4206
Author(s):  
Le Zhou ◽  
Hong Tao Liu

For the further study of bearing compressive capacity of GFRP tube filled with SHC(steel-reinforced high-strength concrete)columns subjected to eccentric compression, and analysis its whole bearing compressive process under eccentric compression. Based on the flat section assumption finite strip method, the calculating program of bearing eccentric compressive capacity of GFRP tube filled with SHC columns is proposed according to existing retrofit theory and related technical procedures. The relation curves of load-deformation is gotten using this calculating program, at the same time it can get the effect curves of concrete strength, slenderness ratio, eccentricity and containing bone rate to load-deformation. Calculations show that the ultimate bearing compressive capacity of composite column decreases with the increase of slenderness ratio, and elastic stage of component curve gradually shortens and stiffness gradually loses; The ultimate bearing compressive capacity of composite columns decreases with the increase of eccentricity; component ductility improves; the ultimate bearing compressive capacity of composite columns increases with the increase of concrete strength. The calculated results agree well with the experimental results and this study provides a basis for practical design.


2016 ◽  
Vol 711 ◽  
pp. 564-571 ◽  
Author(s):  
Thomas Gernay

The use of high strength concrete (HSC) in multi-story buildings has become increasingly popular. Selection of HSC over normal strength concrete (NSC) allows for reducing the dimensions of the columns sections. However, this reduction has consequences on the structural performance in case of fire, as smaller cross sections lead to faster temperature increase in the section core. Besides, HSC experiences higher rates of strength loss with temperature and a higher susceptibility to spalling than NSC. The fire performance of a column can thus be affected by selecting HSC over NSC. This research performs a comparison of the fire performance of HSC and NSC columns, based on numerical simulations by finite element method. The thermal and structural analyses of the columns are conducted with the software SAFIR®. The variation of concrete strength with temperature for the different concrete classes is adopted from Eurocode. Different configurations are compared, including columns with the same load bearing capacity and columns with the same cross section. The relative loss of load bearing capacity during the fire is found to be more pronounced for HSC columns than for NSC columns. The impact on fire resistance rating is discussed. These results suggest that consideration of fire loading limits the opportunities for use of HSC, especially when the objective is to reduce the dimensions of the columns sections.


2013 ◽  
Vol 743 ◽  
pp. 45-49
Author(s):  
Jian Chin Lim ◽  
Togay Ozbakkloglu

This paper presents a study on the axial compressive behavior of fiber reinforced polymer (FRP)-confined high-strength concrete (HSC). A large experimental test database assembled from the published literature was used to investigate and quantify factors influencing the compressive behavior of FRP-confined HSC. The database consisted of 976 test data having unconfined concrete strength ranging from 6.2 to 169.7MPa. Based on the analysis results of the database, it was found that the threshold confinement stiffness increases significantly with an increase in concrete strength, which in turn adversely affects the strength enhancement of confined concrete. It was also observed that the hoop rupture strain of FRP shell decreases with an increase in concrete strength. Existing confinement models that are applicable to FRP-confined HSC were assessed using the database. Finally, a new simple design-oriented model for FRP-confined HSC developed on the basis of the database is presented.


2013 ◽  
Vol 671-674 ◽  
pp. 1860-1864 ◽  
Author(s):  
Thomas Vincent ◽  
Togay Ozbakkloglu

It is well established that external confinement of concrete with fiber reinforced polymer (FRP) sheets results in significant improvements on the axial compressive behavior of concrete. This understanding has led to a large number of experimental studies being conducted over the last two decades. However, the majority of these studies have focused on normal strength concretes (NSC) with compressive strengths lower than 55 MPa, and studies on higher strength concretes have been very limited. This paper presents the results of an experimental study on the compressive behavior of FRP confined high- and ultra high-strength concrete (HSC and UHSC) with average compressive strengths of 65 and 100 MPa. A total of 29 specimens were tested under axial compression to investigate the influence of key parameters such as concrete strength and method of confinement. All specimens were cylindrical, confined with carbon FRP and were 305 mm in height and 152 mm in diameter. Results obtained from the laboratory testing were graphically presented in the form of axial stress-strain relationships and key experimental outcomes are discussed. The results of this experimental study indicate that above a certain confinement threshold, FRP-confined HSC and UHSC exhibit highly ductile behavior. The results also indicate that FRP-wrapped specimens perform similar to concrete-filled FRP tube (CFFT) specimens at ultimate condition, however notable differences are evident at the transition region when comparing stress-strain curves.


2011 ◽  
Vol 261-263 ◽  
pp. 411-415
Author(s):  
Er Bu Tian ◽  
Feng Chao Wang ◽  
Ren Wei Zhang ◽  
Tao Ji

People often use superplasticizer and mineral admixtures (such as steel slag, slag, etc.) to increase the density of concrete and improve concrete strength, but don’t use coarse aggregate gradding. The paper selects the coarse aggregate of skeleton structure from several grading concept, and uses Uniform Design to test high strength concrete workability, and analyses results. It is shown from the results that the method of Uniform Design can significantly reduce the workload, and concrete mixture slump increases linearly with the water-cement ratio and sand percentage, but decreases linearly with steel slag addition, and the water released from the flocculation of cement by superplasticizer can increase the slump, and most of water plays the role of lubricant before it reacts with cement, and the effect of slump that sand extends coarse aggregate skeleton are greater than that sand surface area increases.


Sign in / Sign up

Export Citation Format

Share Document