Novel risk factor for fatal arrhythmia in Brugada syndrome

2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
R Nishinarita ◽  
S Niwano ◽  
N Ishizue ◽  
T Satoh ◽  
G Matsuura ◽  
...  

Abstract Background Brugada syndrome (BrS) is a genetic disease associated with increased risk of ventricular fibrillation (VF)/ventricular tachycardia (VT). The VF/VT in BrS occurs more frequently during a night time or at a rest with parasympathetic nerve activation. Some risk factors of VF/VT occurrence in BrS have been elucidated, however, it remains controversial about risk stratification. Salusin-β is an endogenous bioactive peptide that systemically exerts rapid and profound hypotensive and bradycardic activities and parasympathomimetic hemodynamic actions in vivo. Previous reports suggested that salusin-β is suppressed following physiological parasympathetic stimulation and appears to constitute a negative feedback relationship with the parasympathetic nervous system. Purpose We hypothesized that salusin-β is associated with the occurrence of VF/VT in BrS. Methods The study population consisted of 26 BrS patients with newly implantation of implantable cardioverter defibrillator (ICD) during 2003–2008. In all patients, salusin-β was measured in supine position after 20 minute rest. The date of salusin-β sampling was set as the registration point for this study. The VF/VT was defined as any episode of fatal ventricular tachyarrhythmia or any appropriate shock. In accordance with the presence or absence of VF/VT events within 5 years, all patients were divided into VF/VT group (n=6) and non-VF/VT group (n=20).Various clinical parameters were compared between the two groups. For analysis of autonomic nervous function, heart rate variability (HRV) and pupil function were evaluated. Results The mean age was 54±17 years old. There is no differences between the two groups in clinical parameters. In analysis of HRV, the high-frequency component (0.15–0.40 Hz; HF), low frequency component (0.04–0.15 Hz; LF) and the LF/HF ratio were analyzed over 24 h. LF/HF ratio was significantly lower over 24h in VF/VT groups in comparison with non-VF/VT groups [day-time; 1.8 (1.2–5.6) vs. 5.2 (3.4–8.8), p=0.048, night-time; 1.2 (1.1–1.3) vs. 3.9 (2.5–8.7), p=0.003]. Furthermore, in analysis of pupil function, right/left miosis ratio was higher in VT/VF groups in comparison with non-VT/VF groups [right pupil; 0.39 (0.37–0.59) vs. 0.34 (0.28–0.38), p=0.035, left pupil; 0.43 (0.36–0.50) vs. 0.33 (0.28–0.40), p=0.049]. In plasma total salusin-β levels, the VF/VT groups exhibited significantly lower than non-VF/VT groups (55.2±14.6 vs. 73.2±22.2, p=0.039, Figure). Conclusions Salusin-β was associated with the occurrence of VF/VT in Brugada syndrome. Salusin-β might be useful to identify high-risk patients for the occurrence of VT/VF events in Brugada syndrome. Funding Acknowledgement Type of funding source: None

2000 ◽  
Vol 279 (2) ◽  
pp. H733-H740 ◽  
Author(s):  
Josef Gehrmann ◽  
Peter E. Hammer ◽  
Colin T. Maguire ◽  
Hiroko Wakimoto ◽  
John K. Triedman ◽  
...  

We developed a technology for heart rate (HR) variability (HRV) analysis in the mouse for characterization of HR dynamics, modulated by vagal and sympathetic activity. The mouse is the principal animal model for studying biological processes. Mouse strains are now available harboring gene mutations providing fundamental insights into molecular mechanisms underlying cardiac electrical diseases. Future progress depends on enhanced understanding of these fundamental mechanisms and the implementation of methods for the functional analysis of mouse cardiovascular physiology. By telemetric techniques, standard time and frequency-domain measures of HRV were computed with and without autonomic blockade, and baroreflex sensitivity testing was performed. HR modulation in the high-frequency component is predominantly mediated by the parasympathetic nervous system, whereas the low-frequency component is under the influence of both the parasympathetic and sympathetic systems. The presented technology and protocol allow for assessment of autonomic regulation of the murine HR. Phenotypic screening for HR regulation in mice will further enhance the value of the mouse as a model of heritable electrophysiological human disease.


2020 ◽  
Vol 10 (9) ◽  
pp. 3314 ◽  
Author(s):  
Junichiro Hayano ◽  
Masaya Kisohara ◽  
Norihiro Ueda ◽  
Emi Yuda

Heart rate fragmentation (HRF) is a type of sinoatrial instability characterized by frequent (often every beat) appearance of inflection in the R-R interval time series, despite the electrocardiograms appearing to be sinus rhythm. Because the assessment of parasympathetic function by heart rate variability (HRV) analysis depends on the assumption that the high-frequency component (HF, 0.15–0.4 Hz) of HRV is mediated solely by the cardiac parasympathetic nerve, HRF that is measured as a part of HF power confounds the parasympathetic functional assessment by HRV. In this study, we analyzed HRF in a 24-h electrocardiogram big data and investigated the changes in HRF with age and sex and its influence on the assessment of HRV. We observed that HRF is often observed during childhoods (0–20 year) and increased after 75 year, but it has a large impact on individual differences in HF power at ages 60–90.


Sensors ◽  
2021 ◽  
Vol 21 (14) ◽  
pp. 4895
Author(s):  
Thanh-Vinh Nguyen ◽  
Masaaki Ichiki

This paper reports on a mask-type sensor for simultaneous pulse wave and respiration measurements and eye blink detection that uses only one sensing element. In the proposed sensor, a flexible air bag-shaped chamber whose inner pressure change can be measured by a microelectromechanical system-based piezoresistive cantilever was used as the sensing element. The air bag-shaped chamber is fabricated by wrapping a sponge pad with plastic film and polyimide tape. The polyimide tape has a hole to which the substrate with the piezoresistive cantilever adheres. By attaching the sensor device to a mask where it contacts the nose of the subject, the sensor can detect the pulses and eye blinks of the subject by detecting the vibration and displacement of the nose skin caused by these physiological parameters. Moreover, the respiration of the subject causes pressure changes in the space between the mask and the face of the subject as well as slight vibrations of the mask. Therefore, information about the respiration of the subject can be extracted from the sensor signal using either the low-frequency component (<1 Hz) or the high-frequency component (>100 Hz). This paper describes the sensor fabrication and provides demonstrations of the pulse wave and respiration measurements as well as eye blink detection using the fabricated sensor.


2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Kazuhisa Sugai ◽  
Tomoyoshi Tamura ◽  
Motoaki Sano ◽  
Shizuka Uemura ◽  
Masahiko Fujisawa ◽  
...  

AbstractA recent clinical study demonstrated that haemodialysis with a dialysate containing hydrogen (H2) improves blood pressure control in end-stage kidney disease. Herein, we examined whether H2 has a salutary effect on hypertension in animal models. We subjected 5/6 nephrectomised rats to inhalation of either H2 (1.3% H2 + 21% O2 + 77.7% N2) or control (21% O2 + 79% N2) gas mixture for 1 h per day. H2 significantly suppressed increases in blood pressure after 5/6 nephrectomy. The anti-hypertensive effect of H2 was also confirmed in rats in a stable hypertensive state 3 weeks after nephrectomy. To examine the detailed effects of H2 on hypertension, we used an implanted telemetry system to continuously monitor blood pressure. H2 exerted an anti-hypertensive effect not only during daytime rest, but also during night-time activities. Spectral analysis of blood pressure variability revealed that H2 improved autonomic imbalance, namely by suppressing the overly active sympathetic nervous system and augmenting parasympathetic nervous system activity; these effects co-occurred with the blood pressure-lowering effect. In conclusion, 1-h daily exposure to H2 exerts an anti-hypertensive effect in an animal model of hypertension.


2006 ◽  
Vol 321-323 ◽  
pp. 968-971
Author(s):  
Won Su Park ◽  
Sang Woo Choi ◽  
Joon Hyun Lee ◽  
Kyeong Cheol Seo ◽  
Joon Hyung Byun

For improving quality of a carbon fiber reinforced composite material (CFRP) by preventing defects such as delamination and void, it should be inspected in fabrication process. Novel non-contacting evaluation technique is required because the transducer should be contacted on the CFRP in conventional ultrasonic technique during the non-destructive evaluation and these conventional contact techniques can not be applied in a novel fiber placement system. For the non-destructive evaluation of delamination in CFRP, various methods for the generation and reception of laser-generated ultrasound are applied using piezoelectric transducer, air-coupled transducer, wavelet transform technique etc. The high frequency component of laser-generated guided wave received with piezoelectric sensor disappeared after propagating through delamination region. Air-coupled transducer was tried to be adopted in reception of laser-generated guided wave generated by using linear slit array in order to generate high frequency guided wave with a frequency of 1.1 MHz. Nevertheless, it was failed to receive high frequency guided wave in using air-coupled transducer and linear slit array. Transmitted laser-generated ultrasonic wave was received on back-wall and its frequency was analyzed to establish inspecting technique to detect delamination by non-contact ultrasonic method. In a frequency spectrum analysis, intensity ratio of low frequency and center frequency was approvable parameter to detect delamination.


Author(s):  
Hakaru Tamukoh ◽  
Hideaki Kawano ◽  
Noriaki Suetake ◽  
Masatoshi Sekine ◽  
Byungki Cha ◽  
...  

Heart ◽  
2017 ◽  
Vol 104 (5) ◽  
pp. 423-429 ◽  
Author(s):  
Brittany M Bogle ◽  
Nona Sotoodehnia ◽  
Anna M Kucharska-Newton ◽  
Wayne D Rosamond

ObjectiveVital exhaustion (VE), a construct defined as lack of energy, increased fatigue and irritability, and feelings of demoralisation, has been associated with cardiovascular events. We sought to examine the relation between VE and sudden cardiac death (SCD) in the Atherosclerosis Risk in Communities (ARIC) Study.MethodsThe ARIC Study is a predominately biracial cohort of men and women, aged 45–64 at baseline, initiated in 1987 through random sampling in four US communities. VE was measured using the Maastricht questionnaire between 1990 and 1992 among 13 923 individuals. Cox proportional hazards models were used to examine the hazard of out-of-hospital SCD across tertiles of VE scores.ResultsThrough 2012, 457 SCD cases, defined as a sudden pulseless condition presumed due to a ventricular tachyarrhythmia in a previously stable individual, were identified in ARIC by physician record review. Adjusting for age, sex and race/centre, participants in the highest VE tertile had an increased risk of SCD (HR 1.48, 95% CI 1.17 to 1.87), but these findings did not remain significant after adjustment for established cardiovascular disease risk factors (HR 0.94, 95% CI 0.73 to 1.20).ConclusionsAmong participants of the ARIC study, VE was not associated with an increased risk for SCD after adjustment for cardiovascular risk factors.


2002 ◽  
Vol 282 (3) ◽  
pp. H973-H976 ◽  
Author(s):  
Nobuko Sasano ◽  
Alex E. Vesely ◽  
Junichiro Hayano ◽  
Hiroshi Sasano ◽  
Ron Somogyi ◽  
...  

Respiratory sinus arrhythmia (RSA) may improve the efficiency of pulmonary gas exchange by matching the pulmonary blood flow to lung volume during each respiratory cycle. If so, an increased demand for pulmonary gas exchange may enhance RSA magnitude. We therefore tested the hypothesis that CO2directly affects RSA in conscious humans even when changes in tidal volume (VT) and breathing frequency ( F B), which indirectly affect RSA, are prevented. In seven healthy subjects, we adjusted end-tidal Pco 2 (Pet CO2 ) to 30, 40, or 50 mmHg in random order at constant VT and F B. The mean amplitude of the high-frequency component of R-R interval variation was used as a quantitative assessment of RSA magnitude. RSA magnitude increased progressively with Pet CO2 ( P < 0.001). Mean R-R interval did not differ at Pet CO2 of 40 and 50 mmHg but was less at 30 mmHg ( P < 0.05). Because VT and F B were constant, these results support our hypothesis that increased CO2directly increases RSA magnitude, probably via a direct effect on medullary mechanisms generating RSA.


2017 ◽  
Vol 46 (2) ◽  
pp. 792-801 ◽  
Author(s):  
W-J Guo ◽  
S-K Yao ◽  
Y-L Zhang ◽  
S-Y Du ◽  
H-F Wang ◽  
...  

Objective This study was performed to investigate impaired vagal activity to meal in patients with functional dyspepsia (FD) with delayed gastric emptying (GE). Methods Eighty-five patients were studied. GE parameters, including those in the overall and proximal stomach, were measured by GE functional tests at the Department of Nuclear Medicine. Autonomic nervous function was tested by spectral analysis of heart rate variability (HRV). The vagal activity and sympathetic activity were analyzed by recording the power in the high-frequency component (HF), low-frequency component (LF), and LF/HF ratio. Results Overall and proximal GE were delayed in 47.2% and 50.9% of the patients, respectively. Spectral analysis of HRV showed that the HF in patients with delayed proximal GE was significantly lower and that the LF/HF ratio was significantly higher than those in patients with normal proximal GE after a meal. Conclusion Delayed proximal GE might be caused by disrupted sympathovagal balance as a result of decreased vagal activity after a meal. Improvement in vagal activity may constitute an effective treatment method for patients with FD.


Sign in / Sign up

Export Citation Format

Share Document