scholarly journals Comparison of the Compact Dry EC with the Most Probable Number Method (AOAC Official Method 966.24) for Enumeration of Escherichia coli and Coliform Bacteria in Raw Meats: Performance-Tested MethodSM 110402

2006 ◽  
Vol 89 (1) ◽  
pp. 100-114 ◽  
Author(s):  
Hidemasa Kodaka ◽  
Shingo Mizuochi ◽  
Hajime Teramura ◽  
Tadanobu Nirazuka ◽  
David Goins ◽  
...  

Abstract Compact Dry E. coli/Coliform Count (EC) is a ready-to-use test method for the enumeration of Escherichia coli and coliform bacteria in food. The plates are presterilized and contain culture medium and a cold water-soluble gelling agent. The medium should be rehydrated with 1 mL diluted sample inoculated onto the center of the self-diffusible medium, allowing the solution to diffuse by capillary action. The plate can be incubated at 35C for 2024 h and the colonies counted without any further working steps. The Compact Dry EC medium plates were validated as an analysis tool for determining colony-forming units (CFU) of E. coli and coliform bacteria from a variety of raw meats using 5 different types of raw meats. The performance tests were conducted at 35C. In all studies performed, no apparent differences were observed between the Compact Dry ECmethod and theAOAC Official Method 966.24 results. For the accuracy claim (n = 75), a correlation factor of r2 = 0.93 (E. coli) and r2 = 0.93 (coliform bacteria) could be assigned, as stated in the application for Performance-Tested MethodSM.

2006 ◽  
Vol 89 (1) ◽  
pp. 115-126 ◽  
Author(s):  
Hidemasa Kodaka ◽  
Hajime Teramura ◽  
Tadanobu Nirazuka ◽  
Shingo Mizuochi ◽  
David Goins ◽  
...  

Abstract Compact Dry CF is a ready-to-use test method for the enumeration of coliform bacteria in food. The plates are presterilized and contain culture medium and a cold water-soluble gelling agent. The medium should be rehydrated with 1 mL diluted sample inoculated into the center of the self-diffusible medium, allowing the solution to diffuse by capillary action. The plate can be incubated at 35C for 2024 h and the colonies counted without any further working steps. The Compact Dry CF medium plates were validated with 5 different raw meats. The performance tests were conducted at 35C. In all studies performed, no apparent differences were observed between the Compact Dry CF method and the AOAC Official Method 966.24 results. For the accuracy claim (n = 75), a correlation factor of r2 = 0.91 (coliform) could be assigned, as stated in the application for Performance-Tested MethodSM. No significant variations in coliform bacterial counts were observed with different production lots or plates of diverse storage age by the quality consistency and storage robustness studies.


2019 ◽  
Vol 2 (2) ◽  
pp. a13-19
Author(s):  
ELEXSON NILLIAN ◽  
AMIZA NUR ◽  
DIYANA NUR ◽  
AMIRAH ZAKIRAH ◽  
GRACE BEBEY

Contamination of drinks with E. coli O157:H7 served in food premises such as restaurants can cause haemorrhagic colitis and haemolytic uremic syndrome to humans. The presence or absence of faecal pathogen was demonstrated using coliform group as indicator microorganisms. Therefore, this study was conducted to detect the presence of E. coli O157:H7 in drinking water from food restaurant premise in Kota Samarahan and Kuching to ensure safe and potable drinking water is served to the consumer. A total of thirty (n=30) drink samples including six types of each of the samples are cold plain water, iced tea, iced milo, syrup and iced milk tea. Most Probable Number (MPN) procedure was used in this study to enumerate the MPN values of coliform bacteria in each drink collected. A total of 53.33% (16/30) of the drink samples showed positive E. coli detection. Then, the PCR assay showed 6.25% (one out of 16 isolates) samples were positive and carried stx1 gene produced by E. coli O157:H7 in iced milo sample types. This study showed the drinks collected from food premises was contaminated with faecal contamination, which was not safe to drink by the consumer. Therefore, preventive actions should be taken to prevent foodborne illness outbreak in future


1998 ◽  
Vol 61 (4) ◽  
pp. 444-449 ◽  
Author(s):  
D. E. TOWNSEND ◽  
R. L. IRVING ◽  
A. NAQUI

SimPlate for coliforms and Escherichia coli (CEc) is a new method for the detection and quantification of coliforms and E. coli in food. Internal validation of the method was carried out at IDEXX Laboratories (Westbrook, ME) with 180 food samples representing a variety of different food matrices and compared against three-tube MPN (most probable number), VRBA (violet red bile agar) + MUG, and Petrifilm (E. coli count) methods. SimPlate CEc was highly correlated with each of these methods for the quantification of coliform bacteria (r ≥ 0.90). An insignificant number of food samples were found to contain E. coli; therefore, no meaningful correlation data could be generated. Four hundred forty-four additional food samples were tested at five collaborating laboratories for the presence of coliforms and E. coli using SimPlate CEc and either VRBA + MUG or Petrifilm (E. coli count). Regression analysis of data from SimPlate for CEc versus Petrifilm E. coli count plates generated correlation coefficients (r) of at least 0.89 for total coliforms and at least 0.90 for generic E. coli. Correlation coefficients between SimPlate for CEc and VRBA + MUG data were at least 0.90 for coliforms and at least 0.86 for E. coli. SimPlate for CEc demonstrated better recovery of E. coli than Petrifilm when high populations of bacteria were present. E. coli was not detected in 20 of 50 (40%) raw milk samples tested by the Petrifilm method due to the presence of interfering coliform and noncoliform bacteria. It is concluded that SimPlate for CEc is a suitable alternative for determining numbers of coliform bacteria and E. coli in food.


2010 ◽  
Vol 73 (8) ◽  
pp. 1423-1429 ◽  
Author(s):  
JAVIER CASTRO-ROSAS ◽  
EVA MARÍA SANTOS LÓPEZ ◽  
CARLOS ALBERTO GÓMEZ-ALDAPA ◽  
CESAR ABELARDO GONZÁLEZ RAMÍREZ ◽  
JOSÉ ROBERTO VILLAGOMEZ-IBARRA ◽  
...  

The incidence of coliform bacteria (CB), thermotolerant coliforms (TC), Escherichia coli, and Salmonella was determined for zucchini squash fruit. In addition, the behavior of four serotypes of Salmonella and a cocktail of three E. coli strains on whole and sliced zucchini squash at 25 ± 2°C and 3 to 5°C was tested. Squash fruit was collected in the markets of Pachuca city, Hidalgo State, Mexico. CB, TC, E. coli, and Salmonella were detected in 100, 70, 62, and 10% of the produce, respectively. The concentration ranged from 3.8 to 7.4 log CFU per sample for CB, and <3 to 1,100 most probable number per sample for TC and E. coli. On whole fruit stored at 25 ± 2°C or 3 to 5°C, no growth was observed for any of the tested microorganisms or cocktails thereof. After 15 days at 25 ± 2°C, the tested Salmonella serotypes had decreased from an initial inoculum level of 7 log CFU to <1 log, and at 3 to 5°C they decreased to approximately 2 log. Survival of E. coli was significantly greater than for the Salmonella strains at the same times and temperatures; after 15 days, at 25 ± 2°C E. coli cocktail strains had decreased to 3.4 log CFU per fruit and at 3 to 5°C they decreased to 3.6 log CFU per fruit. Both the Salmonella serotypes and E. coli strains grew when inoculated onto sliced squash: after 24 h at 25 ± 2°C, both bacteria had grown to approximately 6.5 log CFU per slice. At 3 to 5°C, the bacterial growth was inhibited. The squash may be an important factor contributing to the endemicity of Salmonella in Mexico.


1994 ◽  
Vol 77 (1) ◽  
pp. 58-63 ◽  
Author(s):  
Philip T Feldsine ◽  
Maria T Falbo-Nelson ◽  
David L Hustead

Abstract The ColiComplete® substrate-supporting disc (SSD) method for simultaneous confirmed total coliform count and Escherichia coli determination in all foods was compared with the AOAC most probable number (MPN) methods 966.23 and 966.24. In this comparative study, 20 water and food types were analyzed; 7 of these foods were naturally contaminated with coliform bacteria, 6 food types were naturally contaminated with E. coli, and the remaining foods were inoculated with coliform bacteria and/or E. coli. Data were analyzed separately for total coliform bacteria and for E. coli. Mean log MPN counts were determined by the SSD method and the appropriate AOAC MPN procedure. Results were then analyzed for mean log MPN differences and variance, according to methods described by AOAC INTERNATIONAL Results for both total conforms and E. coli indicate that the SSD method is equivalent to or better than AOAC MPN methods 966.23 and 966.24.


2015 ◽  
Vol 14 (1) ◽  
pp. 121-131 ◽  
Author(s):  
Ananda Tiwari ◽  
Seppo I. Niemelä ◽  
Asko Vepsäläinen ◽  
Jarkko Rapala ◽  
Seija Kalso ◽  
...  

The purpose of this equivalence study was to compare an alternative method, Colilert-18 Quanti-Tray (ISO 9308-2) with the European bathing water directive (2006/7/EC) reference method, the miniaturised most probable number (MMPN) method (ISO 9308-3), for the analysis of Escherichia coli. Six laboratories analysed a total of 263 bathing water samples in Finland. The comparison was carried out according to ISO 17994:2004. The recovery of E. coli using the Colilert-18 method was 7.0% and 8.6% lower than that of the MMPN method after 48 hours and 72 hours of incubation, respectively. The confirmation rate of presumptive E. coli-positive wells in the Colilert-18 and MMPN methods was high (97.8% and 98.0%, respectively). However, the testing of presumptive E. coli-negative but coliform bacteria-positive (yellow but not fluorescent) Colilert-18 wells revealed 7.3% false negative results. There were more false negatives in the naturally contaminated waters than in the samples spiked with waste water. The difference between the recovery of Colilert-18 and the MMPN method was considered not significant, and subsequently the methods are considered as equivalent for bathing water quality monitoring in Finland. Future bathing water method equivalence verification studies may use the data reported herein. The laboratories should make sure that any wells showing even minor fluorescence will be determined as positive for E. coli.


Jurnal BIOMA ◽  
2017 ◽  
Vol 11 (1) ◽  
pp. 73
Author(s):  
Rezki Rachmawati ◽  
Muzajjanah Muzajjanah ◽  
Yoswita Rustam

Refill Water Depot is currently more widely circulated and used as an alternative drinking water supply by the public. However the still unclear about the quality of the drinking water refill generated primarily of biological content. Parameters of biological contamination in drinking water caused by the Escherichia coli and coliform bacterium. This study aims to identify E. coli and coliforms in drinking water refill. Refill drinking water samples obtained from 16 drinking water refill from Jagakarsa subdsitrict. The method used is descriptive. Refill drinking water samples was taken and tested in the MPN (Most Probable Number) method and then to be tested in identification of E. coli. The results of testing the drinking water refill obtained 15 samples positive for coliform bacteria. Samples were positive for E. coli bacteria that sample B.1 and F.2.


2021 ◽  
Vol 10 (1) ◽  
pp. 23
Author(s):  
Muhammad Rayhan Braja Gitawama ◽  
Netti Suharti ◽  
Nora Harminarti

The National Food and Drug Agency has controlled the refill drinking water in drinking water depots and also controlled food at school canteens ranging from elementary, junior high, to high school, but the National Food and Drug Agency never do food quality controlling in canteens at universities. Objectives: To identified the contamination by coliform and E. coli bacteria in drinking water at Andalas University canteen. Methods: This research was descriptive to identify coliform bacteria on  15 drinking water at the Andalas University faculty canteens.  Samples were taken directly using a sterile bottle, while data analysis using Most Probable Number  (MPN)  tables 5-1-1 and the presence of E. coli bacteria colonies from drinking water samples. Results: 9 of 15 water samples were contaminated by coliform bacteria with the highest MPN index of 240/100 ml that was found in 2 samples. From 9 samples containing coliform bacteria, all of them were found to contain E. coli bacteria. Conclusion: Most of the samples were contaminated by coliform and E. coli bacteria. Drinking water served using a kettle was more contaminated than drinking water served using gallons.Keywords: Coliform, Escherichia coli, MPN


2015 ◽  
Author(s):  
Tolutope Oluseyi Akeju

Water recreation, though increasing globally, is strongly associated with infectious diseases. Unexpectedly, artificial water recreation systems e.g. swimming pools account for 90% of these outbreaks. It is therefore essential that pool waters be regularly monitored for deviations from microbial water quality guidelines. To assess the sanitary quality of a club swimming pool in Ile-Ife, Nigeria, I used the multiple-tube fermentation technique to determine the most probable number (MPN) of coliform bacteria in 100 ml of pool water. MPN estimates ranged from 9 to 93 with geometric mean of 38. Escherichia coli was isolated from positive presumptive tubes, indicating recent faecal contamination. The isolate elicited similar biochemical reactions as reference E. coli (ATCC-25922), except that it utilized sucrose and liquefied gelatin, which probably indicates potential pathogenicity. Also, the E. coli isolate was resistant to 13 antibiotics from 9 different classes. Finally, coliform counts and detection of E. coli clearly violates international guidelines. I recommend that pool operators increase water disinfection efficiency and educate the public on the need for improved swimmer hygiene to reduce the risk of recreational water illness transmission.


2011 ◽  
Vol 74 (6) ◽  
pp. 874-881 ◽  
Author(s):  
JAVIER CASTRO-ROSAS ◽  
CARLOS A. GÓMEZ-ALDAPA ◽  
OTILIO A. ACEVEDO-SANDOVAL ◽  
CESAR A. GONZÁLEZ RAMÍREZ ◽  
J. ROBERTO VILLAGOMEZ-IBARRA ◽  
...  

The frequencies of coliform bacteria (CB), thermotolerant coliforms (TC), Escherichia coli, and Salmonella were determined for jalapeño and serrano peppers. In addition, the behavior of four serotypes of Salmonella and three E. coli strains on whole and sliced jalapeño and serrano peppers as well as in blended sauce at 25 ± 2°C and 3 to 5°C was investigated. Chili peppers were collected from markets in the city of Pachuca, Hidalgo, Mexico. CB, TC, E. coli, and Salmonella were detected on serrano peppers in 100, 90, 50, and 10% of the samples, and on jalapeño peppers in 100, 86, 32, and 12% of the samples. Concentrations of CB ranged from 3.8 to 7.9 log CFU per serrano sample and from 5.3 to 8.2 log CFU per jalapeño sample, whereas concentrations of TC and E. coli were between <3 and 1,100 most probable number per serrano and jalapeño samples. On whole serrano and jalapeño peppers stored at 25 ± 2°C or 3 to 5°C, no growth was observed for rifampin-resistant strains of Salmonella and E. coli. After 6 days at 25 ± 2°C, the tested Salmonella serotypes and E. coli strains had decreased from an initial inoculum level of 5 log CFU to 1 and 2.5 log on serrano and jalapeño peppers, respectively, and at 3 to 5°C they decreased to approximately 1.8 and 1.2 log, respectively, on serrano and jalapeño. Both the Salmonella serotypes and E. coli grew on sliced chili peppers and in blended sauce; after 24 h at 25 ± 2°C, both bacteria types had grown to approximately 4 and 5 log CFU on pepper slices and in sauce, respectively. At 3 to 5°C the bacterial growth was inhibited.


Sign in / Sign up

Export Citation Format

Share Document