scholarly journals Use of a larger surface area tip on bipolar radiofrequency wands in hip arthroscopy is associated with significantly lower traction and total surgery times

Author(s):  
Austin E Wininger ◽  
Justin O Aflatooni ◽  
Joshua D Harris

ABSTRACT Clinical outcomes in arthroscopic hip preservation surgery have improved over the past two decades due to many factors, including advancements in technique and instrumentation. Complications following hip arthroscopy are associated with increased traction and overall surgical times. The purpose of this study was to compare traction and surgical times during hip arthroscopy using two different radiofrequency ablation wands produced by the same manufacturer. The authors hypothesized that the wand with a larger surface area would result in significantly less traction and surgical times. This study was a retrospective comparative investigation on patients who underwent arthroscopic surgery of the central, peripheral, peritrochanteric and/or deep gluteal space compartments of the hip. Both wands are 50-degree-angled probes, but the tip and shaft diameters are 3 and 3.75 mm for Wand A (Ambient Super MultiVac 50; tip surface area 7.1 mm2) compared to 4.7 and 4.7 mm for Wand B (Ambient HipVac 50; tip surface area 17.3 mm2), respectively. There was no difference (P = 0.16) in mean age of Wand A patients (30 females, 20 males; 35.2 years) versus Wand B patients (31 females, 19 males; 32.7 years). Traction time was significantly less in the Wand B group (41 ± 6 versus 51 ± 18 min; P < 0.001), as was surgical time (102 ± 13 versus 118 ± 17 min; P < 0.001). There were no significant differences in the number of labral anchors used or Current Procedural Terminology codes performed between groups. In conclusion, it was observed that the use of a larger surface area wand was associated with significantly less traction and surgical times during hip arthroscopy.

Heart Rhythm ◽  
2021 ◽  
Vol 18 (8) ◽  
pp. S329
Author(s):  
Elad Anter ◽  
Hagai Yavin ◽  
David Biton ◽  
Zachary Bubar ◽  
Koji Higuchi ◽  
...  

2018 ◽  
Vol 69 (10) ◽  
pp. 2874-2876
Author(s):  
Teodor Negru ◽  
Stefan Mogos ◽  
Ioan Cristian Stoica

Rupture of the anterior cruciate ligament (ACL) is a common injury. The objective of the current study was to evaluate if the learning curve has an impact on surgical time and postoperative clinical outcomes after anatomic single-bundle anterior cruciate ligament reconstruction (ACLR) using an outside-in tunnel drilling hamstrings technique. The learning curve has a positive impact on surgical time but has no influence on postoperative clinical outcomes at short time follow-up.


2021 ◽  
pp. 112070002199626
Author(s):  
Oliver Eberhardt ◽  
Thekla von Kalle ◽  
Rebecca Matthis ◽  
Richard Doepner ◽  
Thomas Wirth ◽  
...  

Introduction: It is often difficult to clinically and radiologically diagnose intra-articular osteoid osteomas and osteoid osteomas of the hip joint. Treatment can also be difficult due to complex locational relationships. CT-guided radiofrequency ablation is currently the standard form of treatment. In this paper we report on a minimally-invasive concept for treating osteoid osteomas near the hip joint in children and adolescents which does not involve using computed tomography. Material and method: 10 patients with an average age of 12.1 years underwent treatment for osteoid osteomas in the hip joint region. The diagnosis was made using a contrast-enhanced MRI. The osteoid osteomas were marked percutaneously using x-ray and MRI guidance. MRI-guided drilling/curettage was performed in 4 cases and arthroscopic resection in 6 cases. Results: All lesions were successfully treated using the MRI-guided method. All patients were free of pain after the treatment. There was no instance of recurrence during the follow-up period, which averaged 10 months. The effective dose for marking the lesion was between 0.0186 mSv and 0.342 mSV (mean 0.084 mSV). Conclusions: Our MRI diagnostics protocol, the MRI-guided drilling and the minimally invasive hip arthroscopy represent an alternative to CT-guided radiofrequency ablation in the treatment of osteoid osteomas. Radiation exposure can thereby be significantly reduced. Hip arthroscopy can also be used to treat secondary pathologies such as femoroacetabular impingement.


2021 ◽  
Vol 9 (2) ◽  
pp. 232596712098198
Author(s):  
Ryan P. McGovern ◽  
John J. Christoforetti ◽  
Benjamin R. Kivlan ◽  
Shane J. Nho ◽  
Andrew B. Wolff ◽  
...  

Background: While previous studies have established several techniques for suture anchor repair of the acetabular labrum to bone during arthroscopic surgery, the current literature lacks evidence defining the appropriate number of suture anchors required to effectively restore the function of the labral tissue. Purpose/Hypothesis: To define the location and size of labral tears identified during hip arthroscopy for acetabular labral treatment in a large multicenter cohort. The secondary purpose was to differentiate the number of anchors used during arthroscopic labral repair. The hypothesis was that the location and size of the labral tear as well as the number of anchors identified would provide a range of fixation density per acetabular region and fixation method to be used as a guide in performing arthroscopic repair. Study Design: Cross-sectional study; Level of evidence, 3. Methods: We used a multicenter registry of prospectively collected hip arthroscopy cases to find patients who underwent arthroscopic labral repair by 1 of 7 orthopaedic surgeons between January 2015 and January 2017. The tear location and number of anchors used during repair were described using the clockface method, where 3 o’clock denoted the anterior extent of the tear and 9 o’clock the posterior extent, regardless of sidedness (left or right). Tear size was denoted as the number of “hours” spanned per clockface arc. Chi-square and univariate analyses of variance were performed to evaluate the data for both the entire group and among surgical centers. Results: A total of 1978 hips underwent arthroscopic treatment of the acetabular labrum; the most common tear size had a 3-hour span (n = 820; 41.5%). Of these hips, 1645 received labral repair, with most common repair location at the 12- to 3-o’clock position (n = 537; 32.6%). The surgeons varied in number of anchors per repair according to labral size ( P < .001 for all), using 1 to 1.6 anchors for 1-hour tears, 1.7 to 2.4 anchors for 2-hour tears, 2.1 to 3.2 anchors for 3-hour tears, and 2.2 to 4.1 for 4-hour tears. Conclusion: Variation existed in the number of anchor implants per tear size. When labral repair involved a mean clockface arc >2 hours, at least 2 anchor points were fixated.


2021 ◽  
pp. 155633162110266
Author(s):  
Ram K. Alluri ◽  
Fedan Avrumova ◽  
Ahilan Sivaganesan ◽  
Avani S. Vaishnav ◽  
Darren R. Lebl ◽  
...  

As robotics in spine surgery has progressed over the past 2 decades, studies have shown mixed results on its clinical outcomes and economic impact. In this review, we highlight the evolution of robotic technology over the past 30 years, discussing early limitations and failures. We provide an overview of the history and evolution of currently available spinal robotic platforms and compare and contrast the available features of each. We conclude by summarizing the literature on robotic instrumentation accuracy in pedicle screw placement and clinical outcomes such as complication rates and briefly discuss the future of robotic spine surgery.