scholarly journals Vapor H2O2 sterilization as a decontamination method for the reuse of N95 respirators in the COVID-19 emergency

Author(s):  
Ebru Oral ◽  
Keith K. Wannomae ◽  
Rachel Connolly ◽  
Joseph Gardecki ◽  
Hui Min Leung ◽  
...  

There are a variety of methods routinely used in the sterilization of medical devices using hydrogen peroxide (H2O2) including vaporization, plasma generation and ionization. Many of these systems are used for sterilization and are validated for bioburden reduction using bacterial spores.Here, we explored the benefits of using vaporized H2O2 (VHP) treatment of N95 respirators for emergency decontamination and reuse to alleviate PPE shortages for healthcare workers in the COVID-19 emergency. The factors that are considered for the effective reuse of these respirators are the fit, the filter efficiency and the decontamination/disinfection level for SARS-CoV-2, which is the causative virus for COVID-19 and other organisms of concern in the hospital environment such as methicillin-resistant Staphylococcus aureus or Clostridium difficile. WE showed that the method did not affect fit or filter efficiency at least for one cycle and resulted in a >6 log reduction in bacterial spores and >3.8 log reduction in the infectious SARS-CoV2 load on N95 respirators.

Author(s):  
Ebru Oral ◽  
Keith K Wannomae ◽  
Dmitry Gil ◽  
Rachel Connolly ◽  
Joseph A Gardecki ◽  
...  

Decontamination of N95 respirators has become critical to alleviate PPE shortages for healthcare workers in the current COVID-19 emergency. The factors that are considered for the effective reuse of these masks are the fit, filter efficiency and decontamination/disinfection level both for SARS-CoV2, which is the causative virus for COVID-19, and for other organisms of concern in the hospital environment such as Staphylococcus aureus or Clostridium difficile.The efficacy of inactivation or eradication against various pathogens should be evaluated thoroughly to understand the level of afforded disinfection. Methods commonly used in the sterilization of medical devices such as ionizing radiation, vaporized hydrogen peroxide, and ethylene oxide can provide a high level of disinfection, defined as a 6 log10 reduction, against bacterial spores, considered the most resistant microorganisms. CDC guidance on the decontamination and reuse of N95s also includes the use of moist heat (60°C, 80% relative humidity, 15-30 min) as a possible recommendation based on literature showing preservation of fit efficiency and inactivation of H1N1 on spiked masks.Here, we explored the efficacy of using moist heat under these conditions as a decontamination method for an N95 respirator (3M 1860S, St. Paul, MN) against various pathogens with different resistance; enveloped RNA viruses, Gram (+/-) bacteria, and non-enveloped viruses.


Author(s):  
Ebru Oral ◽  
Keith K. Wannomae ◽  
Rachel L. Connolly ◽  
Joseph A. Gardecki ◽  
Hui Min Leung ◽  
...  

Decontamination of N95 respirators has become critical to alleviate PPE shortages for healthcare workers in the current COVID-19 emergency. The factors that are considered for the effective reuse of these masks are the fit, filter efficiency and decontamination/disinfection level both for SARS-CoV-2, which is the causative virus for COVID-19, and for other organisms of concern in the hospital environment such as Staphylococcus aureus or Clostridium difficile.In its guidance entitled ‘Recommendations for Sponsors Requesting EUAs for Decontamination and Bioburden Reduction Systems for Surgical Masks and Respirators During the Coronavirus Disease 2019 (COVID19) Public Health Emergency’ (May 2020)[1], the FDA recommends a 6-log10 reduction in either the most resistant bacterial spores for the system or in a mycobacterium species to authorize the use of a decontamination method of N95 respirators for single or multiple users. While the goal is primarily inactivation against SARS-CoV-2, testing of decontamination methods against the virus may not always be available. For decontamination methods considered for only single users, the recommendation is a 6-log10 reduction in the infective virus concentration of 3 non-enveloped viruses or in the concentration of two Gram (+) and two Gram (-) bacteria. Based on these recommendations, we explored the efficacy of vaporized H2O2 (VHP) treatment of N95 respirators against surrogate viruses covering a wide range of disinfection resistance for emergency decontamination and reuse to alleviate PPE shortages for healthcare workers in the COVID-19 emergency.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Avilash K. Cramer ◽  
Deborah Plana ◽  
Helen Yang ◽  
Mary M. Carmack ◽  
Enze Tian ◽  
...  

AbstractThe COVID-19 pandemic has led to widespread shortages of personal protective equipment (PPE) for healthcare workers, including of N95 masks (filtering facepiece respirators; FFRs). These masks are intended for single use but their sterilization and subsequent reuse has the potential to substantially mitigate shortages. Here we investigate PPE sterilization using ionized hydrogen peroxide (iHP), generated by SteraMist equipment (TOMI; Frederick, MD), in a sealed environment chamber. The efficacy of sterilization by iHP was assessed using bacterial spores in biological indicator assemblies. After one or more iHP treatments, five models of N95 masks from three manufacturers were assessed for retention of function based on their ability to form an airtight seal (measured using a quantitative fit test) and filter aerosolized particles. Filtration testing was performed at a university lab and at a National Institute for Occupational Safety and Health (NIOSH) pre-certification laboratory. The data demonstrate that N95 masks sterilized using SteraMist iHP technology retain filtration efficiency up to ten cycles, the maximum number tested to date. A typical iHP environment chamber with a volume of ~ 80 m3 can treat ~ 7000 masks and other items (e.g. other PPE, iPADs), making this an effective approach for a busy medical center.


2021 ◽  
Vol 319 ◽  
pp. 01081
Author(s):  
Samira Jaouhar ◽  
Abdelhakim El Ouali Lalami ◽  
Jawad Bouzid ◽  
Ikrame Zeouk ◽  
Khadija Bekhti

This study aimed to evaluate the bactericidal activity of common disinfectants used for surfaces and medical devices. Sodium hypochlorite (D1), disinfectant (D2) composed of N-(3-aminopropyl)-N-dodecylpropane-1,3-diamine, chloride de didecyldimethylammonium, and disinfectant (D3) composed of Didecyldimethylammonium chloride and Polyhexamethylene biguanide hydrochloride, were tested against 15 strains isolated from the hospital environment and four reference bacteria. The microdilution method was performed to assess antimicrobial activity. The susceptibility was evaluated by comparing the minimum inhibitory dilution with the dilution of disinfectant recommended by the manufacture. D1 and D2 were active against Staphylococcus epidermidis, Staphylococcus saprophyticus, Enterobacter cloacae, Escherichia coli, Pseudomonas fluorescens, Methicillin-resistant Staphylococcus aureus, Bacillus spp, Corynebacterium spp, Gram-positive bacillus, Escherichia coli ATCC 25922, Bacillus subtilis ATCC 3366, and Pseudomonas aeruginosa ATCC 27853 strains but not active against Micrococcus spp, and Staphylococcus aureus ATCC 29213. D3 was ineffective against Micrococcus spp, Bacillus Gram Positive, Staphylococcus epidermidis, and Escherichia coli ATCC 25922. Therefore, D1 and D2 can eliminate most pathogenic bacteria in hospitals, in comparison to D3. It is necessary to monitor the antibacterial activity of disinfectants against reference strains but also against those usually present on surfaces. The obtained results could have promising applications in controlling the emergence of nosocomial infections.


2018 ◽  
Vol 2 (1) ◽  
pp. 30-41 ◽  
Author(s):  
A.G. Salmanov ◽  
O.M. Verner ◽  
N.G. Shelkova ◽  
O.I. Nicolska ◽  
V.M. Blahodatny ◽  
...  

BACKGROUND. Nasal carriage of Staphylococcus aureus among hospital personnel is a common cause of hospital acquired infections. Emergence of drug resistant strains especially methicillin resistant S. aureus (MRSA) is a serious problem in hospital environment. Therefore, the aim of this study was to determine the prevalence of nasal carriage of Staphylococcus aureus its antibiotic susceptibility among healthcare workers (HCWs) in Ukraine. METHODS. This cross-sectional study was conducted from January to December 2017. The study included medical workers from 19 hospitals in different Ukrainian regions. Nasal swabs were taken from 755 randomly selected HCWs. The mean age of participants was 32.41 ± 8.29 years (range 19—74 years) with a male-to- female ratio of 0.47. The isolates were identified as S. aureus based on morphology, Gram stain, catalase test, coagulase test, and mannitol salt agar fermentation. The sensitivity patterns of S. aureus strains were determined by disk diffusion method (Kirby — Bauer). The panel of antibiotics used in sensitivity tests included: penicillin, oxacillin, cefoxitin, amoxicillin/clavulanic acid, gentamicin, tobramicin, ciprofloxacin, levofloxacin, moxifloxacin, mupirocin, nitrofurantoin, vancomycin, teicoplanin, fosfomycin, clindamycin, erythromycin, rifampicin, linezolid, tetracycline, tigecycline, trimethoprim/sulphamethoxazole, and fusidic acid. Interpretative criteria were those suggested by the CLSI (Clinical and Laboratory Standards Institute). MRSA were confirmed by detection of the mecA gene by polymerase chain reaction. RESULTS. Nasal screening identified 31.1 % (235/755) S. aureus carriers. Of the 235 nasal carriers of S. aureus, 4 % (196/755) carried MSSA (methicillin-sensitive S. aureus) and 39/755 (16.6 %) carried MRSA. The frequency of MRSA and MSSA carriage also varied according to the department/ward. The highest prevalence of nasal carriage of MRSA was in the surgical wards. The staff of the general, pediatric, cardiovascular, neuro and orthopedic surgery wards together with the emergency department accounted for 56.4 % of all MRSA carriers. There was no significant difference between the sexes (p = 0.247), age (p = 0.817), and years of healthcare service (p = 0.15) with regard to the nasal carriage of MRSA and MSSA. In univariate analysis we divided the hospital departments into: emergency, internal medicine, pediatrics, ICUs, surgery, and non-medical units and found no significant difference between MSSA and MRSA carriers (p = 0.224). In the multivariate analysis, the occupation «nurse» was independently associated with MRSA carriage (p = 0.012, odds ratio 3.6, 95 % confidence interval 1.3—9.7). All the S. aureus isolates recovered from nasal carriers, were susceptible to linezolid, tigecycline, vancomycin, teicoplanin, and mupirocin. Susceptibility to the other antimicrobials was also on a high level: 98.3 % of strains were found susceptible to trimethoprim/sulphamethoxazole, 96.2 % — to nitrofurantoin, 95.3 % — to fusidic acid, 92.3 % — to fosfomicin, 88.5 % — to amoxicillin/clavulanic acid, 87.2 % — to tobramycin, 86.8 % — to clindamycin. Resistance to oxacyllin came up to 16.6 %. CONCLUSIONS. Nasal carriage of S. aureus appears to play a key role in the epidemiology and pathogenesis of infection. HCWs who are at interface between the hospital and the community may serve as agents of cross contamination of hospital acquired and community acquired MRSA. It is of importance to follow the evolution of resistance to antibiotics in this species, especially to β-lactams.


Author(s):  
Robert J. Fischer ◽  
Dylan H. Morris ◽  
Neeltje van Doremalen ◽  
Shanda Sarchette ◽  
M. Jeremiah Matson ◽  
...  

The unprecedented pandemic of SARS-CoV-2 has created worldwide shortages of personal protective equipment, in particular respiratory protection such as N95 respirators. SARS-CoV-2 transmission is frequently occurring in hospital settings, with numerous reported cases of nosocomial transmission highlighting the vulnerability of healthcare workers. In general, N95 respirators are designed for single use prior to disposal. Here, we have analyzed four readily available and often used decontamination methods: UV, 70% ethanol, 70C heat and vaporized hydrogen peroxide for inactivation of SARS-CoV-2 on N95 respirators. Equally important we assessed the function of the N95 respirators after multiple wear and decontamination sessions.


2020 ◽  
Author(s):  
Mun Cheok Hong ◽  
Tan Sook Lan ◽  
Phua Soo Zeng Fiona ◽  
Lim Wei Qi ◽  
Pang Shyue Wei ◽  
...  

Abstract This study aims to propose decontamination methods that are suitable for use by members of the public to cope with the shortage of surgical masks during the current COVID-19 pandemic. 3-ply surgical masks were subjected to different decontamination protocols (heat, chemical, ultraviolet irradiation) to assess their abilities to achieve at least 4-log reduction of two common respiratory pathogens, H1N1 Influenza A virus, a single-stranded RNA enveloped virus similar to SARS-CoV-2 and Staphylococcus aureus, a Gram-positive bacterium that is more resistant to decontamination than single stranded RNA enveloped virus. Decontaminated surgical masks were assessed for differences in breathability, particle filtration efficiency and bacteria filtration efficiency as compared with non-decontaminated masks. The number of decontamination cycles that the 3-ply surgical masks could undergo without significant changes in breathability and filtration efficiencies were also determined. It was found that surgical masks decontaminated by either soaking for 60 min in 0.5% (v/v) aqueous hydrogen peroxide solution, or 30 min of soaking in 0.05% - 0.5% (v/v) aqueous sodium hypochlorite diluted from household bleach or ultraviolet irradiation by a surface dose of 13.5 kJ/m2 were able to achieve at least a 4-log reduction of both Staphylococcus aureus and H1N1 Influenza A virus spiked on surgical mask test swatches. No significant changes in breathability and filtration efficiencies of the surgical masks were observed after ten decontamination cycles of hydrogen peroxide or diluted bleach treatment or 30 cycles of ultraviolet irradiation.


2020 ◽  
Vol 2020 ◽  
pp. 1-11
Author(s):  
Tiago Danelli ◽  
Felipe Crepaldi Duarte ◽  
Thilara Alessandra de Oliveira ◽  
Raquel Soares da Silva ◽  
Daniela Frizon Alfieri ◽  
...  

Background. Staphylococcus aureus can asymptomatically colonize the human anterior nares and skin, and nasal colonization by this bacterium represents a potential risk for development of invasive infections. The aim of this study was to determine the prevalence of S. aureus nasal carriage among healthcare workers and students attending a university hospital and to characterize the isolates phenotypically and molecularly. Methods. A cross-sectional study was performed with 324 volunteers. Cultures from nasal samples were obtained and S. aureus isolates were characterized according to their antimicrobial susceptibility profile and four virulence factors-encoding genes. MRSA isolates were characterized regarding their oxacillin/cefoxitin susceptibility, SCCmec, and REP-PCR types. Potential risks for S. aureus and MRSA carriage were analyzed. Results. Of 324 nasal samples, 42.9% were identified as S. aureus, of which 28.8% were MRSA. S. aureus carriers were significantly higher in males and students (OR = 2.898, 95%CI 1.553–5.410); however, no variables were associated with MRSA carriage. All isolates were susceptible to vancomycin and the highest rate of resistance was observed for penicillin (90.6%). All isolates harbored the coa gene, and 97.8%, the icaA gene; 15.8% and 6.5% were positive for tst and lukS-PV/lukF-PV genes, respectively. Among MRSA isolates, 45% carried the mecA gene but were phenotypically susceptible to oxacillin/cefoxitin; two harbored the tst and none had lukS-PV/lukF-PV genes. All MRSAs were distributed into six SCCmec types and type I (62.5%) was the most frequent. REP-PCR typing identified four main clusters among MRSA isolates. Conclusion. High prevalence of healthcare workers and students were identified as nasal carriers of S. aureus exhibiting different antimicrobial resistance profiles, including mecA-positive oxacillin-susceptible S. aureus (OS-MRSA) and the presence of virulence-encoding genes. Both cohorts may represent potential sources for the emergence of a successful S. aureus strain highly adapted to the hospital environment.