scholarly journals LUNG ULTRASOUND FINDINGS IN MEXICAN PATIENTS WITH SARS COV2 INFECTION

Author(s):  
Luis Fernando L Paredes ◽  
Ivan I Ilescas

In late December 2019, a new disease reported at the time by an unknown pathogen was reported, which was later found to be a new variant of coronavirus, now called SARS-CoV2. This new disease had a very rapid global spread, causing multiple deaths in a short time, and which led to putting the entire world on health alert. In patients who have this disease, they present bilateral opacities in frosted multilobar glass with peripheral distribution. Some authors have suggested the use of ultrasound at the point of care for its early recognition. In this study, we evaluated the findings of lung ultrasound in 25 patients admitted to the General Hospital Dr. Enrique Cabrera, Mexico, with a diagnosis confirmed by RT-PCR of SARS CoV2. This small retrospective study suggests that artifacts like glass rockets with or without the Birolleau variant (White lung), confluent B-lines, thick irregular pleural lines, and variable size (subpleural) consolidations are typical findings of lung ultrasound in patients with COVID-19 pneumonia. The presence of these findings is useful when evaluating patients with suspected COVID-19. In resource-limited and austere settings where chest radiography, CT, and RT-PCR are not available or the response time is long, lung ultrasound performed by trained personnel can be an aid in the diagnosis of COVID-19.

2020 ◽  
Author(s):  
Andre Kumar ◽  
Yingjie Weng ◽  
Sally Graglia ◽  
Sukyung Chung ◽  
Youyou Duanmu ◽  
...  

Background: Lung ultrasound (LUS) may be used in the diagnostic evaluation of patients with COVID-19. An abnormal LUS is associated with increased risk for ICU admission in COVID-19. Previously described LUS manifestations for COVID-19 include B-lines, consolidations, and pleural thickening. The interrater reliability (IRR) of these findings for COVID-19 is unknown. Research Question: What is the interrater reliability of lung ultrasound findings in patients with RT-PCR confirmed COVID-19? Study Design and Methods: This study was conducted at conducted at two academic medical centers between 03/2020-06/2020. Nine physicians (hospitalists: n=4; emergency medicine: n=5) independently evaluated n=20 LUS scans (n=180 independent observations) collected from RT-PCR confirmed COVID-19 patients. These studies were randomly selected from an image database consisting of COVID-19 patients evaluated in the emergency department with portable ultrasound devices. Physicians were blinded to any patient information or previous LUS interpretation. Kappa values were used to calculate IRR. Results: There was substantial IRR on the following items: normal LUS scan (K=0.79 [95% CI: 0.72-0.87]), presence of B-lines (K=0.79 [95% CI: 0.72-0.87]), >=3 B-lines observed (K=0.72 [95% CI: 0.64-0.79]). Moderate IRR was observed for the presence of any consolidation (K=0.57 [95% CI: 0.50-0.64]), subpleural consolidation (K=0.49 [95% CI: 0.42-0.56]), and presence of effusion (K=0.49 [95% CI: 0.41-0.56]). Fair IRR was observed for pleural thickening (K=0.23 [95% CI: 0.15-0.30]). Interpretation: Many LUS manifestations for COVID-19 appear to have moderate to substantial IRR across providers from multiple specialties utilizing differing portable devices. The most reliable LUS findings with COVID-19 may include the presence/count of B-lines or determining if a scan is normal. Clinical protocols for LUS with COVID-19 may require additional observers for the confirmation of less reliable findings such as consolidations.


2020 ◽  
Vol 2 (11) ◽  
pp. 2151-2157
Author(s):  
Daniel T. Marggrander ◽  
Frauke Borgans ◽  
Volkmar Jacobi ◽  
Holger Neb ◽  
Timo Wolf

AbstractThe current SARS-CoV-2 outbreak leads to a growing need of point-of-care thoracic imaging that is compatible with isolation settings and infection prevention precautions. We retrospectively reviewed 17 COVID-19 patients who received point-of-care lung ultrasound imaging in our isolation unit. Lung ultrasound was able to detect interstitial lung disease effectively; severe cases showed bilaterally distributed B-Lines with or without consolidations; one case showed bilateral pleural plaques. Corresponding to CT scans, interstitial involvement is accurately depicted as B-Lines on lung ultrasound. Lung ultrasound might be suitable for detecting interstitial involvement in a bedside setting under high security isolation precautions.


2020 ◽  
Vol 8 (1) ◽  
pp. 50-50
Author(s):  
Seyed Hossein Ojaghi Haghighi ◽  
Neda Hamed ◽  
Shiva Ebrahimi ◽  
Jafar Ghobadi ◽  
Hoorolnesa Ameli

Introduction: Congestive heart failure is heart muscle failure that causes pulmonary congestion and eventually pulmonary edema, which despite recent medical advances, is still a progressive syndrome with high mortality, the prevalence of which has increased in recent decades. Therefore, in this study we compared lung ultrasound findings in acute heart failure patients with the BNP. Methods: This study was performed in the emergency room of Imam Reza hospital in Tabriz. For patients entering the emergency room after taking a history, both standard gold (BNP) tests and beside ultrasound of the lung were performed. Ultrasound was performed at the same time as obtaining blood sample to ensure that the ultrasound specialist did not know the result of diagnosis. During the ultrasound, if there were multiple B-Lines that were at least 3 mm apart, patient was diagnosed with pulmonary edema due to heart failure. Results: Number of participants in this study was 108 people, 54.6% of whom were men and the rest were women. The correlation coefficient between width and number of kerley lines was 0.79, between NT-pro BNP and width of kerley lines was 0.65 and between NT-pro BNP and number of kerley lines was 0.77, which indicates a significant positive correlation (P value <0.001). Conclusion: The results of present study showed that in patients with acute heart failure, the number and width of kerley lines in pulmonary ultrasound evaluation increase rapidly. There is also a high correlation between number and length of kerley lines with NT-pro BNP serum values.


Author(s):  
Mustafa J. Musa ◽  
Mohamed Yousef ◽  
Mohammed Adam ◽  
Awadalla Wagealla ◽  
Lubna Boshara ◽  
...  

: Lung ultrasound [LUS] has evolved considerably over the last years. The aim of the current review is to conduct a systematic review reported from a number of studies to show the usefulness of [LUS] and point of care ultrasound for diagnosing COVID-19. A systematic search of electronic data was conducted including the national library of medicine, and the national institute of medicine, PubMed Central [PMC] to identify the articles depended on [LUS] to monitor COVID-19. This review highlights the ultrasound findings reported in articles before the pandemic [11], clinical articles before COVID-19 [14], review studies during the pandemic [27], clinical cases during the pandemic [5] and other varying aims articles. The reviewed studies revealed that ultrasound findings can be used to help in the detection and staging of the disease. The common patterns observed included irregular and thickened A-lines, multiple B-lines ranging from focal to diffuse interstitial consolidation, and pleural effusion. Sub-plural consolidation is found to be associated with the progression of the disease and its complications. Pneumothorax was not recorded for COVID-19 patients. Further improvement in the diagnostic performance of [LUS] for COVID-19 patients can be achieved by using elastography, contrast-enhanced ultrasound, and power Doppler imaging.


2020 ◽  
Author(s):  
Andre Kumar ◽  
Sukyung Chung ◽  
Youyou Duanmu ◽  
Sally Graglia ◽  
Farhan Lalani ◽  
...  

IntroductionPoint-of-care ultrasound (POCUS) has the potential to transform healthcare delivery in the era of COVID-19 with its diagnostic and therapeutic expediency. It can be performed by clinicians already at the bedside, which permits an immediate and augmented assessment of a patient. Although lung ultrasound can be used to accurately diagnose a variety of disease states such as pneumothorax, pleural effusions, pneumonia and interstitial lung disease2, there are limited reports on the sonographic manifestations of COVID-19. There is an urgent need to identify alternative diagnostic modalities that can be immediately employed at the bedside of COVID-19 patients.MethodsThis study was conducted at two medical centers in the United States from 3/21/2020-6/01/2020. Any adult who was hospitalized with COVID-19 (based on symptomatology and a confirmatory RT-PCR for SARS-CoV-2) and received a pulmonary POCUS examination was included. Providers were instructed to use a 12-zone scanning protocol for pulmonary views and save 6 second clips of each lung zone. This study utilized several POCUS devices, including Butterfly IQ, Vave, Lumify, and Sonosite. The collected images were interpreted by the study researchers based on a consensus document developed by the study authors and previously accepted definitions of lung POCUS findings.ResultsA total of 22 eligible patients who received 36 lung scans were included in our study. Eleven (50%) patients experienced clinical deterioration (defined as either ICU admission, invasive mechanical ventilation, or death within 28 days from the initial symptom onset). Among the 36 lung scans collected, only 3 (8%) were classified as normal. The remaining scans had the following abnormalities: presence of B-lines (n=32, 89%), consolidations (n=20, 56%), pleural thickening (n=17, 47%), and pleural effusion (n=4, 11%). Out of 20 scans with consolidations, 14 (70%) were subpleural and 5 (25%) were translobar. A-lines were present in 26 (72%) of patients, although they were only observed in the majority of the collected lung zones in 5 (14%) of patients. Ultrasound findings were stratified by time from symptom onset to the scan based on the following time periods: early (0-6 days), middle (7-13 days), and late (14-28 days). B-lines appeared early after symptom onset and persisted well into the late disease course. In contrast, pleural thickening increased in frequency over time (early: 25%, middle: 47%, late: 67%). Subpleural consolidations also appeared in higher frequency later in the disease course (early: 13%, middle 42%, late: 56%).Discussioncertain lung ultrasound findings may be common in Covid-19, while others may appear later in the disease course or only occur in patients who experience clinical deterioration. Future efforts should investigate the predictive utility of consolidations, pleural thickening and B-lines for clinical deterioration and compare them to traditional radiological studies such as X-rays or CTs.


2020 ◽  
Vol 6 (4) ◽  
pp. 00238-2020
Author(s):  
Mark E. Haaksma ◽  
Micah L.A. Heldeweg ◽  
Jorge E. Lopez Matta ◽  
Jasper M. Smit ◽  
Jessica D. van Trigt ◽  
...  

BackgroundOver 2 million people worldwide have been infected with severe acute respiratory distress syndrome-coronavirus-2 (SARS CoV-2). Lung ultrasound has been proposed to diagnose and monitor it, despite the fact that little is known about the ultrasound appearance due to the novelty of the illness. The aim of this manuscript is to characterise the lung ultrasonographic appearance of critically ill patients with SARS-CoV-2 pneumonia, with particular emphasis on its relationship with the time course of the illness and clinical parameters.MethodsAdult patients from the intensive care unit of two academic hospitals who tested positive for SARS-CoV-2 were included. Images were analysed using internationally recognised techniques which included assessment of the pleura, number of B-lines, pathology in the PLAPS (posterolateral alveolar and/or pleural syndrome) point, bedside lung ultrasound in emergency profiles, and the lung ultrasound score. The primary outcomes were frequencies, percentages and differences in lung ultrasound findings overall and between short (≤14 days) and long (>14 days) durations of symptoms and their correlation with clinical parameters.ResultsIn this pilot observational study, 61 patients were included with 76 examinations available for analysis. 26% of patients had no anterior lung abnormalities, while the most prevalent pathological ultrasound findings were thickening of the pleura (42%), ≥3 B-lines per view (38%) and presence of PLAPS (74%). Patients with “long” duration of symptoms presented more frequently with a thickened and irregular pleura (32 (21%) versus 11 (9%)), C-profile (18 (47%) versus 8 (25%)) and pleural effusion (14 (19%) versus 3 (5%)), compared to patients with short duration of symptoms. Lung ultrasound findings did not correlate with arterial oxygen tension/inspiratory oxygen fraction ratio, fluid balance or dynamic compliance.ConclusionSARS-CoV-2 results in significant, but not specific, ultrasound changes, with decreased lung sliding, thickening of the pleura and a B-profile being the most commonly observed. With time, a thickened and irregular pleura, C-profile and pleural effusion become more common findings. When screening patients, a comprehensive ultrasound protocol might be necessary.


2019 ◽  
Vol 5 ◽  
pp. 233372141985844
Author(s):  
Hirofumi Namiki ◽  
Tadashi Kobayashi

The number of aspiration pneumonia cases has increased in recent times. A definitive diagnosis of aspiration pneumonia is difficult in resource-limited settings where radiological equipment is unavailable. We report the initial diagnosis and subsequent monitoring of aspiration pneumonia in a home medical care setting. An 88-year-old Japanese male presented an acute onset of dyspnea, fever, and productive cough. At home, lung ultrasound displayed pleural effusion along with B-lines and subpleural consolidations. Upon admission, tests revealed increased total leucocyte counts with left-shifted neutrophils, elevated C-reactive protein levels, and positive sputum Gram stain. Chest X-ray imaging and computed tomography (CT) showed bibasilar infiltrates and wall thickening in the left S10 bronchi. The patient was diagnosed with aspiration pneumonia and treated with an antibiotic. After a 10-day hospitalization, lung ultrasound showed some remaining B-lines and disappearance of pleural effusion and subpleural consolidation. Chest X-ray image was normal, and CT revealed pleural abnormality and disappearance of bibasilar infiltrates, consistent with the ultrasound findings. Aspiration pneumonia develops with various clinical signs. However, diagnosis using chest X-ray imaging or CT in resource-limited settings is difficult. Ultrasound might allow physicians to make more accurate judgments, particularly while monitoring aspiration pneumonia following initial diagnosis in resource-limited settings.


2021 ◽  
Vol 36 (3) ◽  
pp. 334-342 ◽  
Author(s):  
Kosuke Yasukawa ◽  
Taro Minami ◽  
David R. Boulware ◽  
Ayako Shimada ◽  
Ernest A. Fischer

Background: The prognostic value of point-of-care lung ultrasound has not been evaluated in a large cohort of patients with COVID-19 admitted to general medicine ward in the United States. The aim of this study was to describe lung ultrasound findings and their prognostic value in patients with COVID-19 admitted to internal medicine ward. Method: This prospective observational study consecutively enrolled 105 hospitalized participants with COVID-19 at 2 tertiary care centers. Ultrasound was performed in 12 lung zones within 24 hours of admission. Findings were assessed relative to 4 outcomes: intensive care unit (ICU) need, need for intensive respiratory support, length of stay, and death. Results: We detected abnormalities in 92% (97/105) of participants. The common findings were confluent B-lines (92%), non-homogenous pleural lines (78%), and consolidations (54%). Large confluent B-lines, consolidations, bilateral involvement, and any abnormality in ≥ 6 areas were associated with a longer hospitalization and need for intensive respiratory support. Large confluent B-lines and bilateral involvement were also associated with ICU stay. A total lung ultrasound score <5 had a negative predictive value of 100% for the need of intensive respiratory support. A higher total lung ultrasound score was associated with ICU need (median total 18 in the ICU group vs. 11 non-ICU, p = 0.004), a hospitalization ≥ 9d (15 vs 10, p = 0.016) and need for intensive respiratory support (18 vs. 8.5, P < 0.001). Conclusions: Most patients hospitalized with COVID-19 had lung ultrasound abnormalities on admission and a higher lung ultrasound score was associated with worse clinical outcomes except death. A low total lung ultrasound score (<5) had a negative predictive value of 100% for the need of intensive respiratory support. Point-of-care ultrasound can aid in the risk stratification for patients with COVID-19 admitted to general wards.


Author(s):  
Danilo Buonsenso ◽  
Cristina De Rose ◽  
Valentina Ferro ◽  
Rosa Morello ◽  
Anna Maria Musolino ◽  
...  

Objective and design: Our prospective observational study is the first study that evaluates the LUS findings of cardiopulmonary interactions in acutely ill children with elevated pro-BNP levels,with the aim of establishing the specific LUS pattern in this category of patients without primary lung diseases.Methodology:We prospectively analyzed epidemiological, clinical, laboratory, instrumental and lung ultrasound parameters in acutely ill children aged 1 month to 18 years admitted to the Department of Pediatrics between March 2020 to August 2020.Among the acutely ill patients evaluated, only patients with pro-BNP> 300 pg / ml and who underwent LUS before the start of any treatment were included. They were stratified into three sub-categories based on the diagnosis A) cardiac disease, B) systemic inflammatory disease / sepsis without functional and / or organic alterations of the myocardium and C) systemic inflammatory disease / sepsis and cardiac disease, and were classified into two groups based on the level of pro-BNP.We also enrolled patients belonging to two other categories (patients with primary infectious lung disease and completely healthy patients) analyzing their epidemiological, clinical, laboratory, instrumental parameters and lung ultrasound findings and comparing them with those of acutely ill children.Results and Conclusion: We found that LUS findings in these acutely ill children are different from the ultrasound pattern of other categories of children and in particular 1) children with acute lower respiratory tract infections and 2) healthy infants.The finding in a child of a sonographic interstitial syndrome with multiple, bright, long, separate and non-confluent B-lines / long vertical artefacts deriving from a normal and regular pleural line, in the absence of subpleural consolidations, is strongly predictive of cardiogenic pulmonary edema or pulmonary congestion in the course of systemic inflammatory disease / sepsis.


Praxis ◽  
2021 ◽  
Vol 110 (8) ◽  
pp. 421-425
Author(s):  
Giovanni Volpicelli ◽  
Luciano Cardinale ◽  
Thomas Fraccalini

Abstract. The application of point-of-care lung ultrasound (LUS) in the first diagnosis and management of Corona Virus Disease 2019 (COVID-19) has gained a great interest during a pandemic that is undermining even the most advanced health systems. LUS demonstrated high sensitivity in the visualization of the interstitial signs of the typical pneumonia complicating the infection. However, although this disease gives typical lung alterations, the same LUS signs observed in COVID-19 pneumonia can be detected in other common pulmonary conditions. While being non-specific when considered separately, the analysis of the distribution of the sonographic typical signs allows the assignment of 4 LUS patterns of probability for COVID-19 pneumonia when the whole chest is examined and attention is paid to the presence of other atypical signs. Moreover, the combination of LUS likelihood with the clinical phenotype at presentation increases the accuracy. This mini-review will analyze the LUS signs of COVID-19 pneumonia and how they can be combined in patterns of probability in the first approach to suspected cases.