A Study on the Real-Time Flow Rate Change Monitoring Methods of Mass Flow Controller in In-Situ Semiconductor Processing

Author(s):  
Tae Min Kim ◽  
Jae Wook Jeon
2021 ◽  
Vol 62 (8) ◽  
Author(s):  
Lionel Hirschberg ◽  
Friedrich Bake ◽  
Karsten Knobloch ◽  
Angelo Rudolphi ◽  
Sebastian Kruck ◽  
...  

AbstractMeasurements of sound due to swirl–nozzle interaction are presented. In the experiment a swirl structure was generated by means of unsteady tangential injection into a steady swirl-free flow upstream from a choked convergent–divergent nozzle. Ingestion of swirl by the choked nozzle caused a mass-flow rate change, which resulted in a downstream-measured acoustic response. The downstream acoustic pressure was found to remain negative as long as the swirl is maintained and reflections from the open downstream pipe termination do not interfere. The amplitude of this initial acoustic response was found to be proportional to the square of the tangential mass-flow rate used to generate swirl. When the tangential injection valve was closed, the mass-flow rate through the nozzle increased, resulting in an increase of the downstream acoustic pressure. This increase in signal was compared to the prediction of an empirical quasi-steady model, constructed from steady-state flow measurements. As the opening time of the valve was varied, the signal due to swirl evacuation showed an initial overshoot with respect to quasi-steady behavior, after which it gradually decayed to quasi-steady behavior for tangential injection times long compared to the convection time in the pipe upstream of the nozzle. This demonstrates that the acoustic signal can be used to obtain quantitative information concerning the time dependence of the swirl in the system. This could be useful for understanding the dynamics of flow in engines with swirl-stabilized combustion. Graphic abstract


Author(s):  
Philipp Peter Breese ◽  
Tobias Hauser ◽  
Daniel Regulin ◽  
Stefan Seebauer ◽  
Christian Rupprecht

AbstractThe powder mass flow rate is one of the main parameters regarding the geometrical precision of built components in the additive manufacturing process of laser metal deposition. However, its accuracy, constancy, and repeatability over the course of the running process is not given. Reasons among others are the performance of the powder conveyors, the complex nature of the powder behavior, and the resulting issues with existing closed-loop control approaches. Additionally, a direct in situ measurement of the powder mass flow rate is only possible with intrusive methods. This publication introduces a novel approach to measure the current powder mass flow rate at a frequency of 125 Hz. The volumetric powder flow evaluation given by a simple optical sensor concept was transferred to a mass flow rate through mathematical dependencies. They were found experimentally for a nickel-based powder (Inconel 625) and are valid for a wide range of mass flow rates. With this, the dynamic behavior of a vibration powder feeder was investigated and a memory effect dependent on previous powder feeder speeds was discovered. Next, a closed-loop control with the received sensor signal was implemented. The concept as a whole gives a repeatable and accurate powder mass flow rate while being universally retrofittable and applicable. In a final step, the improved dynamic and steady performance of the powder mass flow rate with closed-loop control was validated. It showed a reduction of mean relative errors for step responses of up to 81% compared to the uncontrolled cases.


Processes ◽  
2021 ◽  
Vol 9 (3) ◽  
pp. 522
Author(s):  
Qiu-Yun Huang ◽  
Ai-Peng Jiang ◽  
Han-Yu Zhang ◽  
Jian Wang ◽  
Yu-Dong Xia ◽  
...  

As the leading thermal desalination method, multistage flash (MSF) desalination plays an important role in obtaining freshwater. Its dynamic modeling and dynamic performance prediction are quite important for the optimal control, real-time optimal operation, maintenance, and fault diagnosis of MSF plants. In this study, a detailed mathematical model of the MSF system, based on the first principle and its treatment strategy, was established to obtain transient performance change quickly. Firstly, the whole MSF system was divided into four parts, which are brine heat exchanger, flashing stage room, mixed and split modulate, and physical parameter modulate. Secondly, based on mass, energy, and momentum conservation laws, the dynamic correlation equations were formulated and then put together for a simultaneous solution. Next, with the established model, the performance of a brine-recirculation (BR)-MSF plant with 16-stage flash chambers was simulated and compared for validation. Finally, with the validated model and the simultaneous solution method, dynamic simulation and analysis were carried out to respond to the dynamic change of feed seawater temperature, feed seawater concentration, recycle stream mass flow rate, and steam temperature. The dynamic response curves of TBT (top brine temperature), BBT (bottom brine temperature), the temperature of flashing brine at previous stages, and distillate mass flow rate at previous stages were obtained, which specifically reflect the dynamic characteristics of the system. The presented dynamic model and its treatment can provide better analysis for the real-time optimal operation and control of the MSF system to achieve lower operational cost and more stable freshwater quality.


2021 ◽  
Vol 11 (15) ◽  
pp. 6701
Author(s):  
Yuta Sueki ◽  
Yoshiyuki Noda

This paper discusses a real-time flow-rate estimation method for a tilting-ladle-type automatic pouring machine used in the casting industry. In most pouring machines, molten metal is poured into a mold by tilting the ladle. Precise pouring is required to improve productivity and ensure a safe pouring process. To achieve precise pouring, it is important to control the flow rate of the liquid outflow from the ladle. However, due to the high temperature of molten metal, directly measuring the flow rate to devise flow-rate feedback control is difficult. To solve this problem, specific flow-rate estimation methods have been developed. In the previous study by present authors, a simplified flow-rate estimation method was proposed, in which Kalman filters were decentralized to motor systems and the pouring process for implementing into the industrial controller of an automatic pouring machine used a complicatedly shaped ladle. The effectiveness of this flow rate estimation was verified in the experiment with the ideal condition. In the present study, the appropriateness of the real-time flow-rate estimation by decentralization of Kalman filters is verified by comparing it with two other types of existing real-time flow-rate estimations, i.e., time derivatives of the weight of the outflow liquid measured by the load cell and the liquid volume in the ladle measured by a visible camera. We especially confirmed the estimation errors of the candidate real-time flow-rate estimations in the experiments with the uncertainty of the model parameters. These flow-rate estimation methods were applied to a laboratory-type automatic pouring machine to verify their performance.


Author(s):  
Mohd. Fua’ad Rahmat ◽  
Wee Lee Yaw

This paper discussed the electrostatic sensors that have been constructed for real–time mass flow rate measurement of particle conveying in a Pneumatic pipeline. Many industrial processes require continuous, smooth, and consistent delivery of solids materials with a high accuracy of controlled flow rate. This requirement can only be achieved by installing a proper measurement system. Electrostatic sensor offers the most inexpensive and simplest means of measuring solids flows in pipes. Key words: Electrostatic sensor, cross-correlation, peripheral velocity


2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Amardeep Bharti ◽  
Keun Hwa Chae ◽  
Navdeep Goyal

AbstractPlasmonic nanostructures are of immense interest of research due to its widespread applications in microelectronics, photonics, and biotechnology, because of its size and shape-dependent localized surface plasmon resonance response. The great efforts have been constructed by physicists, chemists, and material scientists to deliver optimized reaction protocol to tailor the size and shape of nanostructures. Real-time characterization emerges out as a versatile tool in perspective to the optimization of synthesis parameters. Moreover, in the past decades, radiation-induced reduction of metallic-salt to nanoparticles dominates over the conventional direct chemical reduction process which overcomes the production of secondary products and yields ultra-high quality and pure nanostructures. Here we show, the real-time/in-situ synthesis and detection of plasmonic (Au andAg) nanoparticles using single synchrotron monochromatic 6.7 keV X-rays based Nano-Tomography beamline. The real-time X-ray nano-tomography of plasmonic nanostructures has been first-time successfully achieved at such a low-energy that would be leading to the possibility of these experiments at laboratory-based sources. In-situ optical imaging confirms the radiolysis of water molecule resulting in the production of $$e_{aq}^-,\,OH^\bullet ,$$ e aq - , O H ∙ , and $$O_2^-$$ O 2 - under X-ray irradiation. The obtained particle-size and size-distribution by X-ray tomography are in good agreement to TEM results. The effect of different chemical environment media on the particle-size has also been studied. This work provides the protocol to precisely control the size of nanostructures and to synthesize the ultrahigh-purity grade monodisperse nanoparticles that would definitely enhance the phase-contrast in cancer bio-imaging and plasmonic photovoltaic application.


2020 ◽  
Vol 88 ◽  
pp. 19-31 ◽  
Author(s):  
Lei He ◽  
Kai Wen ◽  
Changchun Wu ◽  
Jing Gong ◽  
Xie Ping

2016 ◽  
Vol 28 (6) ◽  
pp. 854-861 ◽  
Author(s):  
Tadayoshi Aoyama ◽  
◽  
Amalka De Zoysa ◽  
Qingyi Gu ◽  
Takeshi Takaki ◽  
...  

[abstFig src='/00280006/09.jpg' width='300' text='Snapshots of particle sorting experiment using our system' ] On-chip cell analysis is an important issue for microtechnology research, and microfluidic devices are frequently used in on-chip cell analysis systems. One approach to controlling the fluid flow in microfluidic devices for cell analysis is to use a suitable pumps. However, it is difficult to control the actual flow-rate in a microfluidic device because of the difficulty in placing flow-rate sensors in the device. In this study, we developed a real-time flow-rate control system that uses syringe pumps and high-speed vision to measure the actual fluid flow in microfluidic devices. The developed flow-rate control system was verified through experiments on microparticle velocity control and microparticle sorting.


Sign in / Sign up

Export Citation Format

Share Document