An Adaptable 6.4 - 32 GS/s Track-and-Hold Amplifier with Track-Mode Masking for High Signal Power Applications in 55 nm SiGe-BiCMOS

Author(s):  
P. Thomas ◽  
M. Buck ◽  
M. Grozing ◽  
M. Berroth ◽  
J. Rauscher ◽  
...  
Keyword(s):  
2020 ◽  
Author(s):  
Venkatesan K ◽  
Chandrasekar A ◽  
Ramesh P.G.V

Abstract In this paper, we discuss the non-linearity problems such as Four Wave Mixing (FWM) and high signal distortion with low Output Signal to Noise Ratio (OSNR) in the design of a 64-channel DWDM system using Regression learning technique. The occurrence of FWM in a DWDM system with high number of channels reduces the performance of an optical fiber system in terms of bandwidth and increases computational complexity. High signal distortion with low OSNR reduces network throughput, energy efficiency and thus forces re-transmission. To overcome the above problems, DWDM system with higher number of channel necessitates an optimized design based on correlation factors of optical dependent and independent variable factors such as BER, Q-factor, signal power, noise power and OSNR. Proposed here is a regression optimized DWDM system design. Regression is used here for correlating and optimizing the optical parameters. In this paper, the problem of non-linearity is solved through optimized DWDM design based on correlated parameters in 16, 32 and 64- Channeled DWDM system. The regression based correlated DWDM design (R-DWDM) is improvised mechanism over the independent parameter based simulations and thus improves accuracy. The R-DWDM design system shows higher accuracy through the derived R-value for optical parameters such as input power, channel spacing, optical gain and data rate. The enhancement achieved through the regression based optimized DWDM design is evaluated in terms of optical measurements such as signal power, noise power, Q-factor and BER.


Author(s):  
D. Van Dyck

An (electron) microscope can be considered as a communication channel that transfers structural information between an object and an observer. In electron microscopy this information is carried by electrons. According to the theory of Shannon the maximal information rate (or capacity) of a communication channel is given by C = B log2 (1 + S/N) bits/sec., where B is the band width, and S and N the average signal power, respectively noise power at the output. We will now apply to study the information transfer in an electron microscope. For simplicity we will assume the object and the image to be onedimensional (the results can straightforwardly be generalized). An imaging device can be characterized by its transfer function, which describes the magnitude with which a spatial frequency g is transferred through the device, n is the noise. Usually, the resolution of the instrument ᑭ is defined from the cut-off 1/ᑭ beyond which no spadal information is transferred.


Author(s):  
Maoxu Qian ◽  
Mehmet Sarikaya ◽  
Edward A. Stern

It is difficult, in general, to perform quantitative EELS to determine, for example, relative or absolute compositions of elements with relatively high atomic numbers (using, e.g., K edge energies from 500 eV to 2000 eV), to study ELNES (energy loss near edge structure) signal using the white lines to determine oxidation states, and to analyze EXELFS (extended energy loss fine structure) to study short range ordering. In all these cases, it is essential to have high signal-to-noise (S/N) ratio (low systematical error) with high overall counts, and sufficient energy resolution (∽ 1 eV), requirements which are, in general, difficult to attain. The reason is mainly due to three important inherent limitations in spectrum acquisition with EELS in the TEM. These are (i) large intrinsic background in EELS spectra, (ii) channel-to-channel gain variation (CCGV) in the parallel detection system, and (iii) difficulties in obtaining statistically high total counts (∽106) per channel (CH). Except the high background in the EELS spectrum, the last two limitations may be circumvented, and the S/N ratio may be attained by the improvement in the on-line acquisition procedures. This short report addresses such procedures.


2020 ◽  
Vol 64 (1-4) ◽  
pp. 951-958
Author(s):  
Tianhao Liu ◽  
Yu Jin ◽  
Cuixiang Pei ◽  
Jie Han ◽  
Zhenmao Chen

Small-diameter tubes that are widely used in petroleum industries and power plants experience corrosion during long-term services. In this paper, a compact inserted guided-wave EMAT with a pulsed electromagnet is proposed for small-diameter tube inspection. The proposed transducer is noncontact, compact with high signal-to-noise ratio and unattractive to ferromagnetic tubes. The proposed EMAT is designed with coils-only configuration, which consists of a pulsed electromagnet and a meander pulser/receiver coil. Both the numerical simulation and experimental results validate its feasibility on generating and receiving L(0,2) mode guided wave. The parameters for driving the proposed EMAT are optimized by performance testing. Finally, feasibility on quantification evaluation for corrosion defects was verified by experiments.


2020 ◽  
Vol 5 (5) ◽  

Background and Objective: Rosai-Dorfman disease (RDD) are usually misdiagnosed because of rarity and nonspecific clinical and radiological features. The aim of our study is to explore the clinical and imaging characteristics of RDD to improve diagnostic accuracy. Methods: Clinical and imaging data in 10 patients with RDD were retrospectively analyzed. 7 patients were underwent CT scanning and 3 patients were underwent MR examination. Results: 8 (8/10) patients presented with painless enlarged lymph nodes (LNs) or mass. 3 cases were involved with LNs, 5 cases were involved with extra-nodal tissues, and the remaining 2 cases were involved with LNs and extra-nodal tissue simultaneously. In enhanced CT images, enlarged LNs displayed mild or moderate enhancement, and 2 cases showed heterogeneous ring-enhancement. MR features of 3 patients with extra-nodal RDD, 2 cases showed a mass located in the subcutaneous and anterior abdominal wall respectively, and 1 case showed an intracranial mass. Besides, all lesions showed high signal foci on DWI images, and were characterized by marked heterogeneous enhancement with blurred edge. The dural/fascia tail sign and dilated blood vessels could be seen around all the lesions on enhanced MRI. Radiological features of 2 cases with LN and extranodal tissue involved, one case presented with the swelling and thickening of pharyngeal lymphoid ring and nasopharynx, meanwhile with enlarged LNs in bilateral submandibular area, neck and abdominal cavity, and also companied with osteolytic lesion in right proximal humerus. All these LNs displayed mild and moderate enhancement on CT images. Another case showed enlarged LNs in bilateral neck accompanied with soft tissue mass in the sinuses. Conclusions: RDD occurred commonly in young and middle-aged men and presented with painless enlarged LNs or mass.RDD had a huge diversity of imaging findings, which varied with different location. The radiological features, such as small patches of high signal foci in the masses on DWI images, heterogeneous enhancement and blood vessels around the masses, are helpful in diagnosis of extranodal RDD.


2020 ◽  
Author(s):  
Shatadru Chakravarty ◽  
Jeremy Hix ◽  
Kaitlyn Wieweora ◽  
Maximilian Volk ◽  
Elizabeth Kenyon ◽  
...  

Here we describe the synthesis, characterization and in vitro and in vivo performance of a series of tantalum oxide (TaOx) based nanoparticles (NPs) for computed tomography (CT). Five distinct versions of 9-12 nm diameter silane coated TaOx nanocrystals (NCs) were fabricated by a sol-gel method with varying degrees of hydrophilicity and with or without fluorescence, with the highest reported Ta content to date (78%). Highly hydrophilic NCs were left bare and were evaluated in vivo in mice for micro-CT of full body vasculature, where following intravenous injection, TaOx NCs demonstrate high CT contrast, circulation in blood for ~ 3 h, and eventual accumulation in RES organs; and following injection locally in the mammary gland, where the full ductal tree structure can be clearly delineated. Partially hydrophilic NCs were encapsulated within mesoporous silica nanoparticles (MSNPs; TaOx@MSNPs) and hydrophobic NCs were encapsulated within poly(lactic-co-glycolic acid) (PLGA; TaOx@PLGA) NPs, serving as potential CT-imagable drug delivery vehicles. Bolus intramuscular injections of TaOx@PLGA NPs and TaOx@MSNPs to mimic the accumulation of NPs at a tumor site produce high signal enhancement in mice. In vitro studies on bare NCs and formuated NPs demonstrate high cytocompatibility and low dissolution of TaOx. This work solidifies that TaOx-based NPs are versatile contrast agents for CT.


2020 ◽  
Author(s):  
Rishikesh Kulkarni ◽  
Anneliese Gest ◽  
Chun Kei Lam ◽  
Benjamin Raliski ◽  
Feroz James ◽  
...  

<p>High signal-to-noise optical voltage indicators will enable simultaneous interrogation of membrane potential in large ensembles of neurons. However, design principles for voltage sensors with high sensitivity and brightness remain elusive, limiting the applicability of voltage imaging. In this paper, we use molecular dynamics (MD) simulations and density functional theory (DFT) calculations to guide the design of a bright and sensitive green-fluorescent voltage-sensitive fluorophore, or VoltageFluor (VF dye), that uses photoinduced electron transfer (PeT) as a voltage-sensing mechanism. MD simulations predict an 11% increase in sensitivity due to membrane orientation, while DFT calculations predict an increase in fluorescence quantum yield, but a decrease in sensitivity due to a decrease in rate of PeT. We confirm these predictions by synthesizing a new VF dye and demonstrating that it displays the expected improvements by doubling the brightness and retaining similar sensitivity to prior VF dyes. Combining theoretical predictions and experimental validation has resulted in the synthesis of the highest signal-to-noise green VF dye to date. We use this new voltage indicator to monitor the electrophysiological maturation of human embryonic stem cell-derived medium spiny neurons. </p>


Author(s):  
Ryan Xiao ◽  
William Wang ◽  
Ang Li ◽  
Shengqiu Xu ◽  
Binghai Liu

Abstract With the development of semiconductor technology and the increment quantity of metal layers in past few years, backside EFA (Electrical Failure Analysis) technology has become the dominant method. In this paper, abnormally high Signal Noise Ratio (SNR) signal captured by Electro-Optical Probing (EOP)/Laser Voltage Probing (LVP) from backside is shown and the cause of these phenomena are studied. Based on the real case collection, two kinds of failure mode are summarized, and simulated experiments are performed. The results indicate that when a current path from power to ground is formed, the high SNR signal can be captured at the transistor which was on this current path. It is helpful of this consequence for FA to identify the failure mode by high SNR signal.


Sign in / Sign up

Export Citation Format

Share Document