Measurement of Stain Area in Metal Surface with Particle Analysis

Author(s):  
Riandini Riandini ◽  
Shahnan Kamil Dewantoro ◽  
Reza Istoni
Author(s):  
L.E. Murr ◽  
V. Annamalai

Georgius Agricola in 1556 in his classical book, “De Re Metallica”, mentioned a strange water drawn from a mine shaft near Schmölnitz in Hungary that eroded iron and turned it into copper. This precipitation (or cementation) of copper on iron was employed as a commercial technique for producing copper at the Rio Tinto Mines in Spain in the 16th Century, and it continues today to account for as much as 15 percent of the copper produced by several U.S. copper companies.In addition to the Cu/Fe system, many other similar heterogeneous, electrochemical reactions can occur where ions from solution are reduced to metal on a more electropositive metal surface. In the case of copper precipitation from solution, aluminum is also an interesting system because of economic, environmental (ecological) and energy considerations. In studies of copper cementation on aluminum as an alternative to the historical Cu/Fe system, it was noticed that the two systems (Cu/Fe and Cu/Al) were kinetically very different, and that this difference was due in large part to differences in the structure of the residual, cement-copper deposit.


Author(s):  
J. R. Porter ◽  
J. I. Goldstein ◽  
D. B. Williams

Alloy scrap metal is increasingly being used in electric arc furnace (EAF) steelmaking and the alloying elements are also found in the resulting dust. A comprehensive characterization program of EAF dust has been undertaken in collaboration with the steel industry and AISI. Samples have been collected from the furnaces of 28 steel companies representing the broad spectrum of industry practice. The program aims to develop an understanding of the mechanisms of formation so that procedures to recover residual elements or recycle the dust can be established. The multi-phase, multi-component dust particles are amenable to individual particle analysis using modern analytical electron microscopy (AEM) methods.Particles are ultrasonically dispersed and subsequently supported on carbon coated formvar films on berylium grids for microscopy. The specimens require careful treatment to prevent agglomeration during preparation which occurs as a result of the combined effects of the fine particle size and particle magnetism. A number of approaches to inhibit agglomeration are currently being evaluated including dispersal in easily sublimable organic solids and size fractioning by centrifugation.


Author(s):  
Y. Kokubo ◽  
W. H. Hardy ◽  
J. Dance ◽  
K. Jones

A color coded digital image processing is accomplished by using JEM100CX TEM SCAN and ORTEC’s LSI-11 computer based multi-channel analyzer (EEDS-II-System III) for image analysis and display. Color coding of the recorded image enables enhanced visualization of the image using mathematical techniques such as compression, gray scale expansion, gamma-processing, filtering, etc., without subjecting the sample to further electron beam irradiation once images have been stored in the memory.The powerful combination between a scanning electron microscope and computer is starting to be widely used 1) - 4) for the purpose of image processing and particle analysis. Especially, in scanning electron microscopy it is possible to get all information resulting from the interactions between the electron beam and specimen materials, by using different detectors for signals such as secondary electron, backscattered electrons, elastic scattered electrons, inelastic scattered electrons, un-scattered electrons, X-rays, etc., each of which contains specific information arising from their physical origin, study of a wide range of effects becomes possible.


Author(s):  
Karen A. Katrinak ◽  
David W. Brekke ◽  
John P. Hurley

Individual-particle analysis is well established as an alternative to bulk analysis of airborne particulates. It yields size and chemical data on a particle-by-particle basis, information that is critical in predicting the behavior of air pollutants. Individual-particle analysis is especially important for particles with diameter < 1 μm, because particles in this size range have a disproportionately large effect on atmospheric visibility and health.


Author(s):  
H. M. Sagara ◽  
S. A. Schliebe ◽  
M. C. Kong

Particle analysis by scanning electron microscopy with energy-dispersive x- ray analysis is one of the current methods used in crime laboratories to aid law enforcement in identifying individuals who have recently fired or handled a firearm. During the discharge of a firearm, the high pressure caused by the detonation of the cartridge materials forces a portion of the generated gases through leaks in the firing mechanism of the weapon. These gases contain residues of smokeless powder, primer mixture, and contributions from the projectile itself. The condensation of these hot gases form discrete, micrometer-sized particles, which can be collected, along with dry skin cells, salts, and other hand debris, from the hands of a shooter by a simple adhesive lift technique. The examination of the carbon-coated adhesive lifts consist of time consuming systematic searches for high contrast particles of spherical morphology with the characteristic elemental composition of antimony, barium and lead. A detailed list of the elemental compositions which match the criteria for gunshot residue are discussed in the Aerospace report.


Author(s):  
Thomas W. Shattuck ◽  
James R. Anderson ◽  
Neil W. Tindale ◽  
Peter R. Buseck

Individual particle analysis involves the study of tens of thousands of particles using automated scanning electron microscopy and elemental analysis by energy-dispersive, x-ray emission spectroscopy (EDS). EDS produces large data sets that must be analyzed using multi-variate statistical techniques. A complete study uses cluster analysis, discriminant analysis, and factor or principal components analysis (PCA). The three techniques are used in the study of particles sampled during the FeLine cruise to the mid-Pacific ocean in the summer of 1990. The mid-Pacific aerosol provides information on long range particle transport, iron deposition, sea salt ageing, and halogen chemistry.Aerosol particle data sets suffer from a number of difficulties for pattern recognition using cluster analysis. There is a great disparity in the number of observations per cluster and the range of the variables in each cluster. The variables are not normally distributed, they are subject to considerable experimental error, and many values are zero, because of finite detection limits. Many of the clusters show considerable overlap, because of natural variability, agglomeration, and chemical reactivity.


Author(s):  
Minakhi Pujari ◽  
Joachim Frank

In single-particle analysis of macromolecule images with the electron microscope, variations of projections are often observed that can be attributed to the changes of the particle’s orientation on the specimen grid (“rocking”). In the multivariate statistical analysis (MSA) of such projections, a single factor is often found that expresses a large portion of these variations. Successful angle calibration of this “rocking factor” would mean that correct angles can be assigned to a large number of particles, thus facilitating three-dimensional reconstruction.In a study to explore angle calibration in factor space, we used 40S ribosomal subunits, which are known to rock around an axis approximately coincident with their long axis. We analyzed micrographs of a field of these particles, taken with 20° tilt and without tilt, using the standard methods of alignment and MSA. The specimen was prepared with the double carbon-layer method, using uranyl acetate for negative staining. In the MSA analysis, the untilted-particle projections were used as active, the tilted-particle projections as inactive objects. Upon tilting, those particles whose rocking axes are parallel to the tilt axis will change their appearance in the same way as under the influence of rocking. Therefore, each vector, in factor space, joining a tilted and untilted projection of the same particle can be regarded as a local 20-degree calibration bar.


Author(s):  
A. Elgsaeter ◽  
T. Espevik ◽  
G. Kopstad

The importance of a high rate of temperature decrease (“rapid freezing”) when freezing specimens for freeze-etching has long been recognized1. The two basic methods for achieving rapid freezing are: 1) dropping the specimen onto a metal surface at low temperature, 2) bringing the specimen instantaneously into thermal contact with a liquid at low temperature and subsequently maintaining a high relative velocity between the liquid and the specimen. Over the last couple of years the first method has received strong renewed interest, particularily as the result of a series of important studies by Heuser and coworkers 2,3. In this paper we will compare these two freezing methods theoretically and experimentally.


1985 ◽  
Author(s):  
F. REDD ◽  
D. BUNNELL ◽  
M. AHMADJIAN
Keyword(s):  

2018 ◽  
Author(s):  
Noor H. Dashti ◽  
Rufika S. Abidin ◽  
Frank Sainsbury

Bioinspired self-sorting and self-assembling systems using engineered versions of natural protein cages have been developed for biocatalysis and therapeutic delivery. The packaging and intracellular delivery of guest proteins is of particular interest for both <i>in vitro</i> and <i>in vivo</i> cell engineering. However, there is a lack of platforms in bionanotechnology that combine programmable guest protein encapsidation with efficient intracellular uptake. We report a minimal peptide anchor for <i>in vivo</i> self-sorting of cargo-linked capsomeres of the Murine polyomavirus (MPyV) major coat protein that enables controlled encapsidation of guest proteins by <i>in vitro</i> self-assembly. Using Förster resonance energy transfer (FRET) we demonstrate the flexibility in this system to support co-encapsidation of multiple proteins. Complementing these ensemble measurements with single particle analysis by super-resolution microscopy shows that the stochastic nature of co-encapsidation is an overriding principle. This has implications for the design and deployment of both native and engineered self-sorting encapsulation systems and for the assembly of infectious virions. Taking advantage of the encoded affinity for sialic acids ubiquitously displayed on the surface of mammalian cells, we demonstrate the ability of self-assembled MPyV virus-like particles to mediate efficient delivery of guest proteins to the cytosol of primary human cells. This platform for programmable co-encapsidation and efficient cytosolic delivery of complementary biomolecules therefore has enormous potential in cell engineering.


Sign in / Sign up

Export Citation Format

Share Document