Session 15: Quantum, power, and compound semiconductors devices - III-V MOSFETs with high k dielectrics

Author(s):  
Patrick Fay
2018 ◽  
Vol 282 ◽  
pp. 39-42 ◽  
Author(s):  
Sang Woo Lim

The integration of III-V and Ge materials on Si surface causes many issues with complexity such as lattice mismatch with silicon. In particular, the surface preparation and passivation of InGaAs is very challenging, because the formation of InGaAs/high-K interface is important, but not well understood. For the systematical study of InGaAs surface during wet processes, the effect of various wet etching processes on the surfaces of binary III-V compound semiconductors (GaAs, InAs, GaSb and InSb) was studied from the viewpoints of surface oxidation, material loss (dissolution), and passivation. Based on that, further effort to understand the surface reactions on ternary InGaAs compound semiconductor was made. In addition, process sequential effect on the InGaAs surface was investigated.


Author(s):  
Avril V. Somlyo ◽  
H. Shuman ◽  
A.P. Somlyo

This is a preliminary report of electron probe analysis of rabbit portal-anterior mesenteric vein (PAMV) smooth muscle cryosectioned without fixation or cryoprotection. The instrumentation and method of electron probe quantitation used (1) and our initial results with cardiac (2) and skeletal (3) muscle have been presented elsewhere.In preparations depolarized with high K (K2SO4) solution, significant calcium peaks were detected over the sarcoplasmic reticulum (Fig 1 and 2) and the continuous perinuclear space. In some of the fibers there were also significant (up to 200 mM/kg dry wt) calcium peaks over the mitochondria. However, in smooth muscle that was not depolarized, high mitochondrial Ca was found in fibers that also contained elevated Na and low K (Fig 3). Therefore, the possibility that these Ca-loaded mitochondria are indicative of cell damage remains to be ruled out.


Author(s):  
D. R. Liu ◽  
S. S. Shinozaki ◽  
R. J. Baird

The epitaxially grown (GaAs)Ge thin film has been arousing much interest because it is one of metastable alloys of III-V compound semiconductors with germanium and a possible candidate in optoelectronic applications. It is important to be able to accurately determine the composition of the film, particularly whether or not the GaAs component is in stoichiometry, but x-ray energy dispersive analysis (EDS) cannot meet this need. The thickness of the film is usually about 0.5-1.5 μm. If Kα peaks are used for quantification, the accelerating voltage must be more than 10 kV in order for these peaks to be excited. Under this voltage, the generation depth of x-ray photons approaches 1 μm, as evidenced by a Monte Carlo simulation and actual x-ray intensity measurement as discussed below. If a lower voltage is used to reduce the generation depth, their L peaks have to be used. But these L peaks actually are merged as one big hump simply because the atomic numbers of these three elements are relatively small and close together, and the EDS energy resolution is limited.


Author(s):  
Cesar D. Fermin ◽  
Hans-Peter Zenner

Contraction of outer and inner hair cells (OHC&IHC) in the Organ of Corti (OC) of the inner ear is necessary for sound transduction. Getting at HC in vivo preparations is difficult. Thus, isolated HCs have been used to study OHC properties. Even though viability has been shown in isolated (iOHC) preparations by good responses to current and cationic stimulation, the contribution of adjoining cells can not be explained with iOHC preparations. This study was undertaken to examine changes in the OHC after expossure of the OHC to high concentrations of potassium (K) and sodium (Na), by carefully immersing the OC in either artifical endolymph or perilymph. After K and Na exposure, OCs were fixed with 3% glutaraldehyde, post-fixed in osmium, separated into base, middle and apex and embedded in Araldite™. One μm thick sections were prepared for analysis with the light and E.M. Cross sectional areas were measured with Bioquant™ software.Potassium and sodium both cause isolated guinea pig OHC to contract. In vivo high K concentration may cause uncontrolled and sustained contractions that could contribute to Meniere's disease. The behavior of OHC in the vivo setting might be very different from that of iOHC. We show here changes of the cell cytosol and cisterns caused by K and Na to OHC in situs. The table below shows results from cross sectional area measurements of OHC from OC that were exposed to either K or Na. As one would expect, from the anatomical arrangement of the OC, OHC#l that are supported by rigid tissue would probably be displaced (move) less than those OHC located away from the pillar. Surprisingly, cells in the middle turn of the cochlea changed their surface areas more than those at either end of the cochlea. Moreover, changes in surface area do not seem to differ between K and Na treated OCs.


2003 ◽  
Vol 765 ◽  
Author(s):  
S. Van Elshocht ◽  
R. Carter ◽  
M. Caymax ◽  
M. Claes ◽  
T. Conard ◽  
...  

AbstractBecause of aggressive downscaling to increase transistor performance, the physical thickness of the SiO2 gate dielectric is rapidly approaching the limit where it will only consist of a few atomic layers. As a consequence, this will result in very high leakage currents due to direct tunneling. To allow further scaling, materials with a k-value higher than SiO2 (“high-k materials”) are explored, such that the thickness of the dielectric can be increased without degrading performance.Based on our experimental results, we discuss the potential of MOCVD-deposited HfO2 to scale to (sub)-1-nm EOTs (Equivalent Oxide Thickness). A primary concern is the interfacial layer that is formed between the Si and the HfO2, during the MOCVD deposition process, for both H-passivated and SiO2-like starting surfaces. This interfacial layer will, because of its lower k-value, significantly contribute to the EOT and reduce the benefit of the high-k material. In addition, we have experienced serious issues integrating HfO2 with a polySi gate electrode at the top interface depending on the process conditions of polySi deposition and activation anneal used. Furthermore, we have determined, based on a thickness series, the k-value for HfO2 deposited at various temperatures and found that the k-value of the HfO2 depends upon the gate electrode deposited on top (polySi or TiN).Based on our observations, the combination of MOCVD HfO2 with a polySi gate electrode will not be able to scale below the 1-nm EOT marker. The use of a metal gate however, does show promise to scale down to very low EOT values.


Sign in / Sign up

Export Citation Format

Share Document