Experimental evaluation on the dielectric breakdown voltage of fresh and used transformer oil mixed with titanium dioxide nanoparticles in the Gilan electrical distribution company

Author(s):  
A Fallah-Shojaie ◽  
A Tavakoli ◽  
M Ghomashpasand ◽  
S Hoseinzadeh
Sensors ◽  
2021 ◽  
Vol 21 (21) ◽  
pp. 7380
Author(s):  
José Miguel Monzón-Verona ◽  
Pablo Ignacio González-Domínguez ◽  
Santiago García-Alonso ◽  
Jenifer Vaswani Reboso

In this paper, a new method for characterizing the dielectric breakdown voltage of dielectric oils is presented, based on the IEC 60156 international standard. In this standard, the effective value of the dielectric breakdown voltage is obtained, but information is not provided on the distribution of Kelvin forces an instant before the dynamic behavior of the arc begins or the state of the gases that are produced an instant after the moment of appearance of the electric arc in the oil. In this paper, the behavior of the oil before and after the appearance of the electric arc is characterized by combining a low-cost CMOS imaging sensor and a new matrix of electrical permittivity associated with the dielectric oil, using the 3D cell method. In this way, we also predict the electric field before and after the electric rupture. The error compared to the finite element method is less than 0.36%. In addition, a new method is proposed to measure the kinematic viscosity of dielectric oils. Using a low-cost imaging sensor, the distribution of bubbles is measured, together with their diameters and their rates of ascent after the electric arc occurs. This method is verified using ASTM standards and data provided by the oil manufacturer. The results of these tests can be used to prevent incipient failures and evaluate preventive maintenance processes such as transformer oil replacement or recovery.


2021 ◽  
Vol 2 ◽  
pp. 19-25
Author(s):  
M. S. Okundamiya ◽  
E. Esekhaigbe ◽  
J. L. Owa ◽  
H. I. Obakhena

The aim of this paper is to determine the effects of ambient temperature variation on the breakdown voltage of a distribution transformer. Three different insulation oil samples (naphtha mineral, paraffin mineral and silicon base transformer oil) were collected from six distribution transformers (300 – 500 kVA) across two business units (Asaba and Ugbowo) of Benin Electricity Distribution Company during May and June, 2017. The oil samples were analysed using the 60 kV Megger OST60PB portable oil tester, to determine the trend of breakdown voltage of the oil insulation under varying temperature. A 3rd order polynomial model was deduced for each sample type with coefficient of determination within the range of 96.99 – 99.95 %. The observed average breakdown voltage is 43.6 kV (for naphtha base mineral transformer oil), 42.2 kV (for paraffin base mineral transformer oil) and 46.8 kV (for silicon base transformer oil) within the temperature range (26˚C – 32˚C). The result indicates that the breakdown voltages of the considered transformer oil types are satisfactory but the silicon base transformer oil has the best breakdown voltage.


Sign in / Sign up

Export Citation Format

Share Document