scholarly journals Performance of a very high voltage photoemission electron gun for a high brightness, high average current erl injector

Author(s):  
B. M. Dunham ◽  
C. K. Sinclair ◽  
I. V. Bazarov ◽  
Y. Li ◽  
X. Liu ◽  
...  
2017 ◽  
Vol 88 (9) ◽  
pp. 093303 ◽  
Author(s):  
C. Hernandez-Garcia ◽  
D. Bullard ◽  
F. Hannon ◽  
Y. Wang ◽  
M. Poelker

Energies ◽  
2020 ◽  
Vol 13 (7) ◽  
pp. 1780 ◽  
Author(s):  
Amir Farakhor ◽  
Mehdi Abapour ◽  
Mehran Sabahi ◽  
Saeid Gholami Farkoush ◽  
Seung-Ryle Oh ◽  
...  

This paper proposes a novel high voltage conversion gain DC/DC boost converter for renewable energy applications and systems. The proposed converter utilizes a three-winding coupled inductor. The presented converter benefits from a unique advantage, as the actual turn ratio of the coupled inductor is decreased in the charging state of the coupled inductor. However, while the inductor is discharging, the actual turn ratio is increased. This feature leads to a very high voltage conversion gain. Furthermore, a passive clamp circuit is employed to recover the leakage current of the coupled inductor. The voltage stresses on the semiconductors are also reduced. In addition, the average current of the primary side of the coupled inductor is zero. This will reduce the total energy stored in the passive elements of the converter. The paper analyzes the Continuous Conduction Mode (CCM) and the operation principles of the presented converter are thoroughly derived. A 250 W laboratory hardware prototype is prepared to verify the proper operation of the presented converter. The obtained experimental results validate the feasibility of the presented converter.


Author(s):  
A. V. Crewe ◽  
M. W. Retsky

A 100 kv scanning transmission microscope has been built. Briefly, the design is as follows: The electron gun consists of a field emission point and a 3 cm Butler gun. The beam has a crossover outside the gun and is collimated by a condenser lens.The parallel beam passes through a defining aperture and is focused by the objective lens onto the specimen. The elastic electrons are detected by two annular detectors, each subtending a different angle, and the unscattered and inelastic electrons are collected by a third detector. The spectrometer that will separate the inelastic and unscattered electrons has not yet been built.The lens current supplies are stable to within one part per million per hour and have been described elsewhere.The high voltage is also stable to 1 ppm/hr. It consists of the raw supply from a 100 kv Spellman power supply controlled by an external reference voltage, high voltage divider, and error amplifier.


Author(s):  
George Christov ◽  
Bolivar J. Lloyd

A new high intensity grid cap has been designed for the RCA-EMU-3 electron microscope. Various parameters of the new grid cap were investigated to determine its characteristics. The increase in illumination produced provides ease of focusing on the fluorescent screen at magnifications from 1500 to 50,000 times using an accelerating voltage of 50 KV.The EMU-3 type electron gun assembly consists of a V-shaped tungsten filament for a cathode with a thin metal threaded cathode shield and an anode with a central aperture to permit the beam to course the length of the column. The cathode shield is negatively biased at a potential of several hundred volts with respect to the filament. The electron beam is formed by electrons emitted from the tip of the filament which pass through an aperture of 0.1 inch diameter in the cap and then it is accelerated by the negative high voltage through a 0.625 inch diameter aperture in the anode which is at ground potential.


Author(s):  
L. F. Allard ◽  
E. Völkl ◽  
T. A. Nolan

The illumination system of the cold field emission (CFE) Hitachi HF-2000 TEM operates with a single condenser lens in normal imaging mode, and with a second condenser lens excited to give the ultra-fine 1 nm probe for microanalysis. The electron gun provides a guaranteed high brightness of better than 7×l08 A/cm2/sr, more than twice the guaranteed brightness of Schottky emission guns. There have been several articles in the recent literature (e.g. refs.) which claim that the geometry of this illumination system yields a total current which is so low that when the beam is spread at low magnifications (say 10 kX), the operator must “keep his eyes glued to the binoculars” in order to see the image. It is also claimed that this illuminating system produces an isoplanatic patch (the area over which image character does not vary significantly) at high magnification which is so small that the instrument is ineffective for recording high resolution images.


Author(s):  
Ryo Iiyoshi ◽  
Susumu Maruse ◽  
Hideo Takematsu

Point cathode electron gun with high brightness and long cathode life has been developed. In this gun, a straightened tungsten wire is used as the point cathode, and the tip is locally heated to higher temperatures by electron beam bombardment. The high brightness operation and some findings on the local heating are presented.Gun construction is shown in Fig.l. Small heater assembly (annular electron gun: 5 keV, 1 mA) is set inside the Wehnelt electrode. The heater provides a disk-shaped bombarding electron beam focusing onto the cathode tip. The cathode is the tungsten wire of 0.1 mm in diameter. The tip temperature is raised to the melting point (3,650 K) at the beam power of 5 W, without any serious problem of secondary electrons for the gun operation. Figure 2 shows the cathode after a long time operation at high temperatures, or high brightnesses. Evaporation occurs at the tip, and the tip part retains a conical shape. The cathode can be used for a long period of time. The tip apex keeps the radius of curvature of 0.4 μm at 3,000 K and 0.3 μm at 3,200 K. The gun provides the stable beam up to the brightness of 6.4×106 A/cm2sr (3,150 K) at the accelerating voltage of 50 kV. At 3.4×l06 A/cm2sr (3,040 K), the tip recedes at a slow rate (26 μm/h), so that the effect can be offset by adjusting the Wehnelt bias voltage. The tip temperature is decreased as the tip moves out from the original position, but it can be kept at constant by increasing the bombarding beam power. This way of operation is possible for 10 h. A stepwise movement of the cathode is enough for the subsequent operation. Higher brightness operations with the rapid receding rates of the tip may be improved by a continuous movement of the wire cathode during the operations. Figure 3 shows the relation between the beam brightness, the tip receding rate by evaporation (αis the half-angle of the tip cone), and the cathode life per unit length, as a function of the cathode temperature. The working life of the point cathode is greatly improved by the local heating.


Electronics ◽  
2021 ◽  
Vol 10 (3) ◽  
pp. 313
Author(s):  
Jacek Rąbkowski ◽  
Andrzej Łasica ◽  
Mariusz Zdanowski ◽  
Grzegorz Wrona ◽  
Jacek Starzyński

The paper describes major issues related to the design of a portable SiC-based DC supply developed for evaluation of a high-voltage Marx generator. This generator is developed to be a part of an electromagnetic cannon providing very high voltage and current pulses aiming at the destruction of electronics equipment in a specific area. The portable DC supply offers a very high voltage gain: input voltage is 24 V, while the generator requires supply voltages up to 50 kV. Thus, the system contains two stages designed on the basis of SiC power devices operating with frequencies up to 100 kHz. At first, the input voltage is boosted up to 400 V by a non-isolated double-boost converter, and then a resonant DC-DC converter with a special transformer elevates the voltage to the required level. In the paper, the main components of the laboratory setup are presented, and experimental results of the DC supply and whole system are also shown.