Performance analysis of a voltage source converter HVDC system connected to an independent power generating station

Author(s):  
R. S. Geetha ◽  
Ravishankar Deekshit ◽  
G. Lal
Energies ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 3097
Author(s):  
Roberto Benato ◽  
Antonio Chiarelli ◽  
Sebastian Dambone Sessa

The purpose of this paper is to highlight that, in order to assess the availability of different HVDC cable transmission systems, a more detailed characterization of the cable management significantly affects the availability estimation since the cable represents one of the most critical elements of such systems. The analyzed case study consists of a multi-terminal direct current system based on both line commutated converter and voltage source converter technologies in different configurations, whose availability is computed for different transmitted power capacities. For these analyses, the matrix-based reliability estimation method is exploited together with the Monte Carlo approach and the Markov state space one. This paper shows how reliability analysis requires a deep knowledge of the real installation conditions. The impact of these conditions on the reliability evaluation and the involved benefits are also presented.


2013 ◽  
Vol 3 (2) ◽  
Author(s):  
Guo-Jie Li ◽  
Si-Ye Ruan ◽  
Tek Lie

AbstractA multi-terminal voltage-source-converter (VSC) based high voltage direct current (HVDC) system is concerned for its flexibility and reliability. In this study, a control strategy for multiple VSCs is proposed to auto-share the real power variation without changing control mode, which is based on “dc voltage droop” power regulation functions. With the proposed power regulation design, the multiple VSCs automatically share the real power change and the VSC-HVDC system is stable even under loss of any one converter while there is no overloading for any individual converter. Simulation results show that it is effective to balance real power for power disturbance and thus improves operation reliability for the multi-terminal VSC-HVDC system by the proposed control strategy.


Energies ◽  
2020 ◽  
Vol 13 (9) ◽  
pp. 2260
Author(s):  
Fan Cheng ◽  
Lijun Xie ◽  
Zhibing Wang

This paper investigated the characteristics of a novel type of hybrid high voltage direct current (HVdc) converter, which is composed by line commutated converter series with voltage source converter. The system and valve level control strategies are introduced, which can provide ac system voltage support. A novel filter design scheme composed by resonant filers for hybrid HVdc are also proposed, which can decrease the capacity of reactive power compensation equipment without deteriorate harmonic characteristics. The ac voltage of HVdc fluctuation level caused by transmitted power variation will be effectively reduced, with the coordination between filter design scheme and converter control. In addition, the influence of ac grid strength is also analyzed by equivalent source internal impedance represented by short circuit ratio (SCR). Finally, the +800 kV/1600 MW hybrid HVdc system connecting two ac grids under different SCR cases are studied, and the PSCAD/EMTDC simulation results have validated the effectiveness for proposed strategy.


Energies ◽  
2020 ◽  
Vol 13 (14) ◽  
pp. 3554
Author(s):  
Naushath M. Haleem ◽  
Athula D. Rajapakse ◽  
Aniruddha M. Gole ◽  
Ioni T. Fernando

A selective fault clearing scheme is proposed for a hybrid voltage source converter (VSC)-line commutated converter (LCC) multi-terminal high voltage direct current (HVdc) transmission structure in which two small capacity VSC stations tap into the main transmission line of a high capacity LCC-HVdc link. The use of dc circuit breakers (dc CBs) on the branches connecting to VSCs at the tapping points is explored to minimize the impact of tapping on the reliability of the main LCC link. This arrangement allows clearing of temporary faults on the main LCC line as usual by force retardation of the LCC rectifier. The faults on the branches connecting to VSC stations can be cleared by blocking insulated gate bipolar transistors (IGBTs) and opening ac circuit breakers (ac CB), without affecting the main line’s performance. A local voltage and current measurement based fault discrimination scheme is developed to identify the faulted sections and pole(s), and trigger appropriate fault recovery functions. This fault discrimination scheme is capable of detecting and discriminating short circuits and high resistances faults in any branch well before 2 ms. For the test grid considered, 6 kA, 2 ms dc CBs can easily facilitate the intended fault clearing functions and maintain the power transfer through healthy pole during single-pole faults.


2013 ◽  
Vol 860-863 ◽  
pp. 2269-2274
Author(s):  
Hao Yang Cui ◽  
Yong Peng Xu ◽  
Jun Jie Yang ◽  
Jun Dong Zeng ◽  
Zhong Tang

As the feature of faulty signal in high voltage direct current transmission technology based on voltage source converter (VSC-HVDC) system is complicated to extract and its difficult to carry on the fault diagnosis. On the basis of the PSCAD simulation model of VSC-HVDC system, the DC current faulty signal is analyzed. Then, the wavelet analysis method was adopted to extract the eigenvector of faulty signal, and combined with method of Bayesian regularization back-propagation (BRBP) neural networks, the system fault was identified. The simulation results show that the method is more efficiently and more rapidly than the adding momentum BP neural network on the VSC-HVDC system faults diagnosing.


Author(s):  
Prabodha Kumar Rath ◽  
Kanhu Charan Bhuyan

<span lang="EN-US">This paper proposes a model of a VSC (voltage source converter) based Back to Back HVDC system and its control technique under fault condition. From the mathematical model of the system relationship between the controlling and the controlled variables is determined to control the system parameters. An appropriate vector control technique is used to control active and reactive power and to maintain DC link voltage. The proposed controlling unit consists of outer control loop and inner control loop which effectively damped out the system oscillation and maintains the system stability. The validity of the model and the feasibility of the control method have been proved by the simulation results. In this paper the system performance is studied under fault condition is studied.</span>


2021 ◽  
Vol 16 ◽  
pp. 164-177
Author(s):  
Bell David Du Hong ◽  
Ha Thu Le

As higher demand for power becomes a global concern and offshore power generation becomes more popular, more options should be explored. This study investigates the use of bifacial photovoltaic (PV) panels for offshore solar farms. In addition, it explores the use of HVDC for transmitting the solar power to onshore grid. The results show that bifacial panels have much higher efficiency compared to monofacial panels where the efficiency improvement ranges from 8.5% to 24.8% for a wide range of irradiance (100-1000 W/m2). The newer Voltage Source Converter (VSC) HVDC has high potential for future deployment thanks to its advantages. However, the harmonics from a considered VSC-HVDC system is severe. Some fitters have been designed to mitigate the harmonics. LC low-pass filters are proved to be most effective where they reduce the Total Harmonics Distortion (THD) of the system output voltage from 68.84% to 2.93%. The results are supportive for developing offshore solar farms that provide green energy while preserving land for other purposes.


2019 ◽  
Vol 217 ◽  
pp. 01004
Author(s):  
Yang Zhou ◽  
Stefan Dalhues ◽  
Ulf Häger

The integration of the voltage-source converter based high voltage direct current (VSC-HVDC) system makes the set-point of its active power adaptive to the changes in the power flow, and contributes to the curative congestion management. To further exploit the dynamic behavior of a hybrid AC/DC power system in curative congestion management scenarios, this paper investigates a novel control scheme for voltage angle droop controlled HVDC (VAD-HVDC) systems. The proposed scheme to alleviate the circuit overload is estimated firstly by calculating the severity index when the power flow changes under N-1 situations. Then the voltage angle controlled HVDC system is applied on the modified IEEE 39-bus 10-machine test power system for the time-domain simulation. The dynamic behavior in the HVDC station validates that the VAD control can stabilize the DC voltage and possess a good ability against interference. In addition, the dynamic characteristics analysis on the AC transmission lines proves that the hybrid AC/DC system integrated with the VAD controlled HVDC system are in possession of good stability after the N-1 contingency event. The VAD controller employed in the HVDC system is capable of effective congestion management to mitigate the critical loadings on the transmission lines.