A Logarithmic Current-to-Voltage Amplifier with High Sensitivity, Stability, and Dynamic Range, Suitable for Field Application

1966 ◽  
Vol 13 (1) ◽  
pp. 602-610 ◽  
Author(s):  
Stanley R. Bishop
Author(s):  
F. Ouyang ◽  
D. A. Ray ◽  
O. L. Krivanek

Electron backscattering Kikuchi diffraction patterns (BKDP) reveal useful information about the structure and orientation of crystals under study. With the well focused electron beam in a scanning electron microscope (SEM), one can use BKDP as a microanalysis tool. BKDPs have been recorded in SEMs using a phosphor screen coupled to an intensified TV camera through a lens system, and by photographic negatives. With the development of fiber-optically coupled slow scan CCD (SSC) cameras for electron beam imaging, one can take advantage of their high sensitivity and wide dynamic range for observing BKDP in SEM.We have used the Gatan 690 SSC camera to observe backscattering patterns in a JEOL JSM-840A SEM. The CCD sensor has an active area of 13.25 mm × 8.83 mm and 576 × 384 pixels. The camera head, which consists of a single crystal YAG scintillator fiber optically coupled to the CCD chip, is located inside the SEM specimen chamber. The whole camera head is cooled to about -30°C by a Peltier cooler, which permits long integration times (up to 100 seconds).


Author(s):  
N. Mori ◽  
T. Oikawa ◽  
Y. Harada ◽  
J. Miyahara ◽  
T. Matsuo

The Imaging Plate (IP) is a new type imaging device, which was developed for diagnostic x ray imaging. We have reported that usage of the IP for a TEM has many merits; those are high sensitivity, wide dynamic range, and good linearity. However in the previous report the reading system was prototype drum-type-scanner, and IP was also experimentally made, which phosphor layer was 50μm thick with no protective layer. So special care was needed to handle them, and they were used only to make sure the basic characteristics. In this article we report the result of newly developed reading, printing system and high resolution IP for practical use. We mainly discuss the characteristics of the IP here. (Precise performance concerned with the reader and other system are reported in the other article.)Fig.1 shows the schematic cross section of the IP. The IP consists of three parts; protective layer, phosphor layer and support.


2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Libo Zhang ◽  
Zhiqingzi Chen ◽  
Kaixuan Zhang ◽  
Lin Wang ◽  
Huang Xu ◽  
...  

AbstractThe advent of topological semimetals enables the exploitation of symmetry-protected topological phenomena and quantized transport. Here, we present homogeneous rectifiers, converting high-frequency electromagnetic energy into direct current, based on low-energy Dirac fermions of topological semimetal-NiTe2, with state-of-the-art efficiency already in the first implementation. Explicitly, these devices display room-temperature photosensitivity as high as 251 mA W−1 at 0.3 THz in an unbiased mode, with a photocurrent anisotropy ratio of 22, originating from the interplay between the spin-polarized surface and bulk states. Device performances in terms of broadband operation, high dynamic range, as well as their high sensitivity, validate the immense potential and unique advantages associated to the control of nonequilibrium gapless topological states via built-in electric field, electromagnetic polarization and symmetry breaking in topological semimetals. These findings pave the way for the exploitation of topological phase of matter for high-frequency operations in polarization-sensitive sensing, communications and imaging.


2002 ◽  
Vol 38 (13) ◽  
pp. 650 ◽  
Author(s):  
H. Matsuda ◽  
A. Miura ◽  
H. Irie ◽  
S. Tanaka ◽  
K. Ito ◽  
...  

1991 ◽  
Vol 9 (2) ◽  
pp. 579-591 ◽  
Author(s):  
L. Pína ◽  
H. Fiedorowicz ◽  
M. O. Koshevoi ◽  
A. A. Rupasov ◽  
B. Rus ◽  
...  

A program is under way to develop methods and instrumentation based on charge-coupled device (CCD) sensors for hot plasma diagnostics. We have developed a new X-ray spectrometer in which a freestanding X-ray transmission grating is coupled to a CCD linear array detector with electronic digitized readout replacing film and its wet processing. This instrument measures time-integrated pulsed X-ray spectra with moderate spectral resolution (δλ ≤ 0.6 nm) over a broad spectral range (0.3–2 keV) with high sensitivity, linearity, and large dynamic range. The performance of the device was tested using laser plasma as the X-ray source.


1993 ◽  
Vol 330 ◽  
Author(s):  
John Kasianowicz ◽  
Barbara Walker ◽  
Musti Krishnasastry ◽  
Hagan Bayley

ABSTRACTWe are adapting proteins that form pores in lipid bilayers for use as components of biosensors. Specifically, we have produced genetically engineered variants of the α hemolysin (αHL) fromStaphylococcusaureus with properties that are sensitive to low concentrations of divalent cations. For example, the pore-forming activity of one mutant (αHL-H5: residues 130–134 inclusive replaced with histidine) is inhibited by Zn2+at concentrations as low as 1 μM, as judged by the reduction in its ability to lyse rabbit red blood cells and to increase the conductance of planar lipid bilayer membranes. When αHL-H5 is added to the aqueous phase bathing one side of a planar membrane, the subsequent addition of 100 μM Zn2+to either side blocks the pores that form. This result suggests that at least part of the mutated region lines the channel lumen. Ca2+and Mg2+do not block the channel and therefore the H5 mutation confers a degree of analyte specificity to the αHL pore. The results suggest that genetically engineered pores have great promise for the rapid and sensitive detection of metal cations and we discuss the merits and potential limitations for their use in this application. Specifically, we examine the issues of selectivity, sensitivity, response time, dynamic range and longevity. Some of these properties are interdependent. For example, the goals of high sensitivity and rapid response time can be in conflict.


2012 ◽  
Vol 162 ◽  
pp. 487-496 ◽  
Author(s):  
Aurelien Yeremou Tamtsia ◽  
Youcef Mezouar ◽  
Philippe Martinet ◽  
Haman Djalo ◽  
Emmanuel Tonye

Among region-based descriptors, geometric moments have been widely exploited to design visual servoing schemes. However, they present several disadvantages such as high sensitivity to noise measurement, high dynamic range and information redundancy (since they are not computed onto orthogonal basis). In this paper, we propose to use a class of orthogonal moments (namely Legendre moments) instead of geometric moments to improve the behavior of moment-based control schemes. The descriptive form of the interaction matrix related to the Legendre moments computed from a set of points is rst derived. Six visual features are then selected to design a partially-decoupled control scheme. Finally simulated and experimental results are presented to illustrate the validity of our proposal.


Pharmaceutics ◽  
2021 ◽  
Vol 13 (7) ◽  
pp. 1019
Author(s):  
Teresa von Linde ◽  
Gzona Bajraktari-Sylejmani ◽  
Walter E. Haefeli ◽  
Jürgen Burhenne ◽  
Johanna Weiss ◽  
...  

The peptide transporter PEPT-1 (SLC15A1) plays a major role in nutritional supply with amino acids by mediating the intestinal influx of dipeptides and tripeptides generated during food digestion. Its role in the uptake of small bioactive peptides and various therapeutics makes it an important target for the investigation of the systemic absorption of small peptide-like active compounds and prodrug strategies of poorly absorbed therapeutics. The dipeptide glycyl-sarcosine (Gly-Sar), which comprises an N-methylated peptide bond that increases stability against enzymatic degradation, is widely utilized for studying PEPT-1-mediated transport. To support experiments on PEPT-1 inhibitor screening to identify potential substrates, we developed a highly sensitive Gly-Sar quantification assay for Caco-2 cell lysates with a dynamic range of 0.1 to 1000 ng/mL (lower limit of quantification 0.68 nM) in 50 µL of cell lysate. The assay was validated following the applicable recommendations for bioanalytic method validation of the FDA and EMA. Sample preparation and quantification were established in 96-well cell culture plates that were also used for the cellular uptake studies, resulting in a rapid and robust screening assay for PEPT-1 inhibitors. This sample preparation principle, combined with the high sensitivity of the UPLC-MS/MS quantification, is suitable for screening assays for PEPT-1 inhibitors and substrates in high-throughput formats and holds the potential for automation. Applicability was demonstrated by IC50 determinations of the known PEPT-1 inhibitor losartan, the known substrates glycyl-proline (Gly-Pro), and valaciclovir, the prodrug of aciclovir, which itself is no substrate of PEPT-1 and consequently showed no inhibition in our assay.


2007 ◽  
Vol 98 (1) ◽  
pp. 502-512 ◽  
Author(s):  
Michael T. Lippert ◽  
Kentaroh Takagaki ◽  
Weifeng Xu ◽  
Xiaoying Huang ◽  
Jian-Young Wu

We describe methods to achieve high sensitivity in voltage-sensitive dye (VSD) imaging from rat barrel and visual cortices in vivo with the use of a blue dye RH1691 and a high dynamic range imaging device (photodiode array). With an improved staining protocol and an off-line procedure to remove pulsation artifact, the sensitivity of VSD recording is comparable with that of local field potential recording from the same location. With this sensitivity, one can record from ∼500 individual detectors, each covering an area of cortical tissue 160 μm in diameter (total imaging field ∼4 mm in diameter) and a temporal resolution of 1,600 frames/s, without multiple-trial averaging. We can record 80–100 trials of intermittent 10-s trials from each imaging field before the VSD signal reduces to one half of its initial amplitude because of bleaching and wash-out. Taken together, the methods described in this report provide a useful tool for visualizing evoked and spontaneous waves from rodent cortex.


Sign in / Sign up

Export Citation Format

Share Document