Trade-Off Assessments for Part Load Controlled Cooling Air in Stationary Gas Turbines

2021 ◽  
Author(s):  
Dominik Woelki ◽  
Dieter Peitsch
2019 ◽  
Author(s):  
Dominik Woelki ◽  
◽  
Dieter Peitsch ◽  
Jonas Foret ◽  
Louise Dittmar ◽  
...  

2020 ◽  
Vol 142 (10) ◽  
Author(s):  
Dominik Woelki ◽  
Dieter Peitsch

Abstract The demand for flexible part load operation of stationary gas turbines requires the simultaneous design for sufficient efficiency and lifetime. Both can be addressed by the secondary air system. This paper presents investigations on the concepts of cooling air reduction in off-design, aiming for tradeoffs between fuel burn and turbine blade life. The considered lifetime mechanisms are creep and oxidation. In addition, the effects on emissions from the combustion are outlined. The reference gas turbine is a generic gas turbine in the 300 MW power output segment. The focus is on the first two stages of the four-stage turbine. All simulations are performed by application of a coupled model that essentially connects gas turbine performance with a secondary air system network model. This coupled model is now extended with blade life evaluation and emission models. The results contain tradeoffs for operating points at base and part load. For example, the combined cooling air control of stage 1 rotor blade and stage 2 vane offers savings up to 0.5% fuel flow at 60% of base load in a combined cycle application. This saving is at the expense of creep life. However, some operating points could even operate at higher blade temperatures in order to improve life regarding hot corrosion. Furthermore, generic sensitivities of controlled secondary air supply to cooling layers and hot gas ingestion are discussed. Overall, the presented trades mark promising potentials of modulated secondary air system concepts from a technical point of view.


Author(s):  
Dominik Woelki ◽  
Dieter Peitsch

Abstract The demand for flexible operation of stationary gas turbines, especially at part load, requires the simultaneous design for sufficient efficiency and life time. Both can be addressed by the secondary air system. The here applied concept modulates cooling air supply in off-design. Typically, a reduction of cooling air leads to higher efficiency but shorter turbine life time. This paper presents investigations on such concepts, aiming for trade-offs between fuel burn and turbine blade life. The considered life time mechanisms are creep, which is dominant in rotor blades, and oxidation. In addition, the effects on emissions from the combustion are outlined. The reference gas turbine is a literature-based, generic gas turbine in the 300 MWpower output segment. Regarding cooling air control, the focus is on the first two stages of the four-stage turbine. All simulations are performed by application of component zooming with an appropriate in-house tool: a previously introduced coupled model of the reference gas turbine that essentially connects gas turbine performance with a secondary air system network model. This coupled model is now extended with blade life evaluation and emission models. The results contain trade-offs for different operating points at base and part load. For example, the combined cooling air control of stage 1 rotor blade and stage 2 vane offers several benefits regarding fuel consumption: saving up to Δwfuel,rel = 0.5% in the heat recovery’s kink point operation at 60 % of base load of a combined cycle application. This saving is at the expense of creep life. However, some operating points could even operate at higher blade temperatures in order to improve life regarding hot corrosion. Furthermore, generic sensitivities of controlled secondary air supply to cooling layers and hot gas ingestion at rim seals are discussed. Overall, the presented trades mark promising potentials of modulated secondary air system concepts from a technical point of view.


Author(s):  
Karl W. Karstensen ◽  
Jesse O. Wiggins

Gas turbines have been accepted in naval surface ship applications, and considerable effort has been made to improve their fuel consumption, particularly at part-load operation. This is an important parameter for shipboard engines because both propulsion and electrical-generator engines spend most of their lives operating at off-design power. An effective way to improve part-load efficiency of recuperated gas turbines is by using a variable power turbine nozzle. This paper discusses the successful use of variable power turbine nozzles in several applications in a family of engines developed for vehicular, industrial, and marine use. These engines incorporate a variable power turbine nozzle and primary surface recuperator to yield specific fuel consumption that rivals that of medium speed diesels. The paper concentrates on the experience with the variable nozzle, tracing its derivation from an existing fixed vane nozzle and its use across a wide range of engine sizes and applications. Emphasis is placed on its potential in marine propulsion and auxiliary gas turbines.


Author(s):  
Budimir Rosic ◽  
John D. Denton ◽  
John H. Horlock ◽  
Sumiu Uchida

This paper numerically investigates the interaction between multiple can combustors and the first vane in an industrial gas turbine with 16 can combustors and 32 vanes in order to find ways of reducing the overall cooling requirements. Two promising concepts for the overall cooling reduction are presented. In the first, by minimising the axial distance between the combustor wall and the vane, the stagnation region at the LE of every second vane can be effectively shielded from the hot mainstream gases. The LE shielding allows continuous cooling slots to be used (as an alternative to discrete cooling holes) to cool downstream parts of the vane using a portion of the saved LE showerhead cooling air. The second concept proposes a full combustor and first vane integration. In this novel concept the number of vanes is halved and the combustor walls are used to assist the flow turning. All remaining vanes are fully integrated into the combustor walls. In this way the total wetted area of the integrated system is reduced, and by shielding the LEs of the remaining vanes the total amount of cooling air can be reduced. The proposed combustor and first vane integration does not detrimentally affect the aerodynamics of the combustor and vane system. The concept also simplifies the design and should lower the manufacturing costs.


2021 ◽  
Author(s):  
Silvia Ravelli

Abstract This study takes inspiration from a previous work focused on the simulations of the Willem-Alexander Centrale (WAC) power plant located in Buggenum (the Netherlands), based on integrated gasification combined cycle (IGCC) technology, under both design and off-design conditions. These latter included co-gasification of coal and biomass, in proportions of 30:70, in three different fuel mixtures. Any drop in the energy content of the coal/biomass blend, with respect to 100% coal, translated into a reduction in gas turbine (GT) firing temperature and load, according to the guidelines of WAC testing. Since the model was found to be accurate in comparison with operational data, here attention is drawn to the GT behavior. Hence part load strategies, such as fuel-only turbine inlet temperature (TIT) control and inlet guide vane (IGV) control, were investigated with the aim of maximizing the net electric efficiency (ηel) of the whole plant. This was done for different GT models from leading manufactures on a comparable size, in the range between 190–200 MW. The influence of fuel quality on overall ηel was discussed for three binary blends, over a wide range of lower heating value (LHV), while ensuring a concentration of H2 in the syngas below the limit of 30 vol%. IGV control was found to deliver the highest IGCC ηel combined with the lowest CO2 emission intensity, when compared not only to TIT control but also to turbine exhaust temperature control, which matches the spec for the selected GT engine. Thermoflex® was used to compute mass and energy balances in a steady environment thus neglecting dynamic aspects.


2017 ◽  
Vol 39 (4) ◽  
pp. 11-20
Author(s):  
A. A. Khalatov ◽  
A. S. Kovalenko ◽  
S. B. Reznik

The features of the release of the cooling air in the interscapular channel high temperature gas turbines at the film cooling are considered. Possibilities of its local distribution on contour of an entrance edge of the perforated blades are investigated. The presented calculations show that the substantial increase in the cooling efficiency can be attained due to channels of small dimension in the blade wall.  


Author(s):  
SS Talebi ◽  
AM Tousi ◽  
A Madadi ◽  
M Kiaee

Recently, the utilization of micro gas turbines in smart grids are rising that makes the part-load operation principal situation of the engine service. This leads to faster life consumption that increases the importance of the diagnostics process. Gas path analysis is an effective method for gas turbine diagnostics. Complex dynamics of gas turbine induces challenging conditions to perform applicable gas path analysis. This study aims to facilitate MGT gas path diagnostics through reducing the number of monitoring parameters and preparation a pattern for engine level and component level health assessment in both full and part load operation of a recuperated micro gas turbine. To attain this goal a model is proposed to simulate MGT off-design performance which is validated against experimental data in healthy and degraded operation modes. Fouling in compressor, turbine and recuperator and erosion in compressor and turbine as the most common degradations in the gas turbine are considered. The fault simulation is performed by changing the health parameters of gas path components. According to the result investigation, a matrix comprises deviation contours of four parameters, Power, fuel flow, compressor discharge pressure, and exhaust gas temperature is presented and analyzed. The analysis shows that monitoring these parameters makes it possible to perform engine level and component level diagnostics through evaluating a binary code (generated by mentioned parameter variations) against the fault effects pattern in different load fractions and fault severities. The simulation also showed that the most power drop occurred under the compressor fouling by about 8.7% while the most reduction in thermal efficiency is observed under recuperator fouling by about 7.84%. Furthermore, the investigation showed the maximum decrease in the surge margin induced by the compressor fouling during the lower part-load operation by about 45.7% while in the higher loads created by the turbine fouling by about 14%.


Author(s):  
Nicolai Neumann ◽  
Dieter Peitsch ◽  
Arne Berthold ◽  
Frank Haucke ◽  
Panagiotis Stathopoulos

Abstract Performance improvements of conventional gas turbines are becoming increasingly difficult and costly to achieve. Pressure Gain Combustion (PGC) has emerged as a promising technology in this respect, due to the higher thermal efficiency of the respective ideal gas turbine cycle. Previous cycle analyses considering turbine cooling methods have shown that the application of pressure gain combustion may require more turbine cooling air. This has a direct impact on the cycle efficiency and reduces the possible efficiency gain that can potentially be harvested from the new combustion technology. Novel cooling techniques could unlock an existing potential for a further increase in efficiency. Such a novel turbine cooling approach is the application of pulsed impingement jets inside the turbine blades. In the first part of this paper, results of pulsed impingement cooling experiments on a curved plate are presented. The potential of this novel cooling approach to increase the convective heat transfer in the inner side of turbine blades is quantified. The second part of this paper presents a gas turbine cycle analysis where the improved cooling approach is incorporated in the cooling air calculation. The effect of pulsed impingement cooling on the overall cycle efficiency is shown for both Joule and PGC cycles. In contrast to the authors’ anticipation, the results suggest that for relevant thermodynamic cycles pulsed impingement cooling increases the thermal efficiency of Joule cycles more significantly than it does in the case of PGC cycles. Thermal efficiency improvements of 1.0 p.p. for pure convective cooling and 0.5 p.p. for combined convective and film with TBC are observed for Joule cycles. But just up to 0.5 p.p. for pure convective cooling and 0.3 p.p. for combined convective and film cooling with TBC are recorded for PGC cycles.