Mechanical Contact Frequency Response Measurements

2000 ◽  
Vol 122 (4) ◽  
pp. 828-833 ◽  
Author(s):  
S. S. Kupchenko ◽  
D. P. Hess

This paper presents friction frequency response measurements taken from a planar steel contact subjected to controlled random broadband normal vibration. Data are included from both dry and various lubricated contact conditions under different vibration input levels and different sliding velocities. Frequency response data for dry contacts are found to have nearly steady magnitude and negligible phase lag over a relatively wide range of frequencies. This suggests a coefficient of friction, independent of frequency but dependent on levels of normal acceleration and sliding velocity, may adequately define the dry contact frequency response. The frequency response data for lubricated contacts are mixed. For example, with MoS2 grease the frequency response may adequately be defined by a constant, as with dry conditions. However, frequency response data for contacts with pure mineral oils, mineral oils with additives, and lithium grease are found to be dependent on frequency. [S0742-4787(11)00101-9]

1988 ◽  
Vol 59 (4) ◽  
pp. 1143-1161 ◽  
Author(s):  
T. J. Anastasio ◽  
M. J. Correia

1. The horizontal and vertical vestibuloocular reflex (HVOR and VVOR, respectively) was studied in four chronically instrumented pigeons. Eye movements were measured using the magnetic search-coil technique and were produced by rotation in the dark. During the rotation paradigms, the pigeons were either pharmacologically aroused (using amphetamine) or drug free (normal). The pigeon HVOR and VVOR were tested using step and sinusoidal rotational stimulation. The range of frequencies (0.03-6.0 Hz) and the magnitude of the sinusoidal stimuli were chosen to match those used in a previous study of the responses of semicircular canal primary afferents (SCPAs) in unanesthetized (i.e., normal) pigeons. 2. The gain of the HVOR and VVOR in both normal and aroused pigeons was independent of stimulus magnitude (6-30 degrees/s) over the frequency range tested. In aroused pigeons, the frequency independent gain (G) of the HVOR (G = 0.6) and VVOR (G = 0.9) was roughly twice that for normal pigeons. Pigeon VOR phase under all combinations of orientation and arousal level was independent of stimulus magnitude except at the lowest frequency tested (0.03 Hz). At this frequency, phase lead decreased as stimulus magnitude increased for the HVOR and VVOR in both normal and aroused pigeons. 3. The step and sinusoidal gains were greater for the VVOR than for the HVOR under the same level of arousal. Neither the gain nor the dominant time constant of the VOR (tau vor) differed for rotation direction (clockwise or counterclockwise) for the HVOR or VVOR in normal or aroused pigeons. 4. The mean value of tau vor was 4.0 +/- 0.5 (SE) s as estimated from frequency response data and 4.3 +/- 0.4 s as estimated from step response data for the HVOR and VVOR in both normal and aroused pigeons. In comparison, the mean value of the dominant or cupular time constant (tau c) of normal pigeon SCPAs was approximately 10 s as estimated from frequency response data. These results indicate that tau vor is shorter than tau c in the pigeon. 5. At higher frequencies, the pigeon HVOR and VVOR exhibit an increasing phase lag unaccompanied by a gain change--characteristics produced by a pure time delay. The value of this time delay was about 7 ms for both the HVOR and VVOR in both normal and aroused pigeons. The HVOR and VVOR in normal and aroused pigeons lacked the higher frequency lead characteristics present in the frequency responses of most pigeon SCPAs.


2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Ákos Sudár ◽  
Gergely Futaki ◽  
Róbert Kovács

Abstract The thermal modeling of biological systems is increasingly important in the development of more advanced and more precise techniques such as ultrasound surgery. One of the primary barriers is the complexity of biological materials: the geometrical, structural, and material properties vary in a wide range. In the present paper, we focus on the continuum modeling of heterogeneous materials of biological origin. There are numerous examples in the literature for non-Fourier thermal models. However, as we realized, they are associated with a few common misconceptions. Therefore, we first aim to clarify the basic concepts of non-Fourier thermal models. These concepts are demonstrated by revisiting two experiments from the literature in which the Cattaneo–Vernotte and the dual phase lag models are utilized. Our investigation revealed that these non-Fourier models are based on misinterpretations of the measured data, and the seeming deviation from Fourier’s law originates from the source terms and boundary conditions.


Nanomaterials ◽  
2021 ◽  
Vol 11 (7) ◽  
pp. 1752
Author(s):  
Blanca Jalvo ◽  
Andrea Aguilar-Sanchez ◽  
Maria-Ximena Ruiz-Caldas ◽  
Aji P. Mathew

This article presents a comparative study of the surface characteristics and water purification performance of commercially available cellulose nonwoven fabrics modified, via cast coating, with different nano-dimensioned bio-based carbohydrate polymers, viz. cellulose nanocrystals (CNC), TEMPO-oxidized cellulose nanofibers (T-CNF), and chitin nanocrystals (ChNC). The surface-modified nonwoven fabrics showed an improvement in wettability, surface charge modification, and a slight decrease of maximum pore size. The modification improved the water permeance in most of the cases, enhanced the particle separation performance in a wide range of sizes, upgraded the mechanical properties in dry conditions, and showed abiotic antifouling capability against proteins. In addition, T-CNF and ChNC coatings proved to be harmful to the bacteria colonizing on the membranes. This simple surface impregnation approach based on green nanotechnology resulted in highly efficient and fully bio-based high-flux water filtration membranes based on commercially available nonwoven fabrics, with distinct performance for particle rejection, antifouling and antibacterial properties.


2016 ◽  
Vol 27 (03) ◽  
pp. 219-236 ◽  
Author(s):  
Susan Scollie ◽  
Danielle Glista ◽  
Julie Seto ◽  
Andrea Dunn ◽  
Brittany Schuett ◽  
...  

Background: Although guidelines for fitting hearing aids for children are well developed and have strong basis in evidence, specific protocols for fitting and verifying technologies can supplement such guidelines. One such technology is frequency-lowering signal processing. Children require access to a broad bandwidth of speech to detect and use all phonemes including female /s/. When access through conventional amplification is not possible, the use of frequency-lowering signal processing may be considered as a means to overcome limitations. Fitting and verification protocols are needed to better define candidacy determination and options for assessing and fine tuning frequency-lowering signal processing for individuals. Purpose: This work aims to (1) describe a set of calibrated phonemes that can be used to characterize the variation in different brands of frequency-lowering processors in hearing aids and the verification with these signals and (2) determine whether verification with these signal are predictive of perceptual changes associated with changes in the strength of frequency-lowering signal processing. Finally, we aimed to develop a fitting protocol for use in pediatric clinical practice. Study Sample: Study 1 used a sample of six hearing aids spanning four types of frequency lowering algorithms for an electroacoustic evaluation. Study 2 included 21 adults who had hearing loss (mean age 66 yr). Data Collection and Analysis: Simulated fricatives were designed to mimic the level and frequency shape of female fricatives extracted from two sources of speech. These signals were used to verify the frequency-lowering effects of four distinct types of frequency-lowering signal processors available in commercial hearing aids, and verification measures were compared to extracted fricatives made in a reference system. In a second study, the simulated fricatives were used within a probe microphone measurement system to verify a wide range of frequency compression settings in a commercial hearing aid, and 27 adult listeners were tested at each setting. The relation between the hearing aid verification measures and the listener’s ability to detect and discriminate between fricatives was examined. Results: Verification measures made with the simulated fricatives agreed to within 4 dB, on average, and tended to mimic the frequency response shape of fricatives presented in a running speech context. Some processors showed a greater aided response level for fricatives in running speech than fricatives presented in isolation. Results with listeners indicated that verified settings that provided a positive sensation level of /s/ and that maximized the frequency difference between /s/ and /∫/ tended to have the best performance. Conclusions: Frequency-lowering signal processors have measureable effects on the high-frequency fricative content of speech, particularly female /s/. It is possible to measure these effects either with a simple strategy that presents an isolated simulated fricative and measures the aided frequency response or with a more complex system that extracts fricatives from running speech. For some processors, a more accurate result may be achieved with a running speech system. In listeners, the aided frequency location and sensation level of fricatives may be helpful in predicting whether a specific hearing aid fitting, with or without frequency-lowering, will support access to the fricatives of speech.


2013 ◽  
Vol 14 (6) ◽  
pp. 549-559 ◽  
Author(s):  
Krupa Shah ◽  
K. Ragavan

Abstract This article focuses on developing a non-invasive method for determining capacitances using frequency response data. The proposed methodology involves acquiring driving-point impedance of the winding under consideration over wide frequency range. With certain terminal conditions and using the terminal impedance measured at specific frequencies, input and shunt capacitances are determined. For the purpose of estimating series capacitance of the winding, an algorithm is proposed. To demonstrate the capability of the method, initially model coils that have provisions for connecting external capacitances are considered. Then, it is found that the estimated values of capacitances are nearly same as those of connected capacitances. The method is, then, extended to transformer winding, and a capacitive ladder network is constructed. To assess the accuracy of estimation, capacitive voltage distribution is utilized. That is, the voltage distribution in the winding is compared with that of synthesized circuit. A good agreement between those data reveals that the estimated capacitance values are accurate.


2012 ◽  
Vol 1 (33) ◽  
pp. 50 ◽  
Author(s):  
Le Phuong Dong ◽  
Shinji Sato

Prototype scale laboratory experiments have been conducted to investigate the sheetflow sediment transport of uniform sands under different skewed-asymmetric oscillatory flows. Experimental results reveal that in most of the case with fine sand, the “cancelling effect”, which balances the on-/off-shore net transport under pure asymmetric/skewed flows and results a moderate net transport, was developed for combined skewed-asymmetric flow. However, under some certain conditions (T > 5s) with coarse sands, the onshore sediment transport was enhanced by 50% under combined skewed-asymmetric flows. Sand transport mechanism under oscillatory sheetflow conditions is also studied by comparing the maximum bed shear stress and the phase lag parameter at each half cycle. A comparison of measurements including the new experimental data with a number of practical sand transport formulations shows that the Dong et al. (2013) formulation performs the best in predicting the measured net transport rates over a wide range of experimental conditions


Sign in / Sign up

Export Citation Format

Share Document