Analysis of Thermal Effects in a Cavitating Orifice Using Rayleigh Equation and Experiments

Author(s):  
Maria Grazia De Giorgi ◽  
Daniela Bello ◽  
Antonio Ficarella

The cavitation phenomenon interests a wide range of machines, from internal combustion engines to turbines and pumps of all sizes. It affects negatively the hydraulic machines’ performance and may cause materials’ erosion. The cavitation, in most cases, is a phenomenon that develops at a constant temperature, and only a relatively small amount of heat is required for the formation of a significant volume of vapor, and the flow is assumed isothermal. However, in some cases, such as thermosensible fluids and cryogenic liquid, the heat transfer needed for the vaporization is such that phase change occurs at a temperature lower than the ambient liquid temperature. The focus of this research is the experimental and analytical studies of the cavitation phenomena in internal flows in the presence of thermal effects. Experiments have been done on water and nitrogen cavitating flows in orifices at different operating conditions. Transient growth process of the cloud cavitation induced by flow through the throat is observed using high-speed video images and analyzed by pressure signals. The experiments show different cavitating behaviors at different temperatures and different fluids; this is related to the bubble dynamics inside the flow. So to investigate possible explanations for the influence of fluid temperature and of heat transfer during the phase change, initially, a steady, quasi-one-dimensional model has been implemented to study an internal cavitating flow. The nonlinear dynamics of the bubbles has been modeled by Rayleigh–Plesset equation. In the case of nitrogen, thermal effects in the Rayleigh equation are taken into account by considering the vapor pressure at the actual bubble temperature, which is different from the liquid temperature far from the bubble. A convective approach has been used to estimate the bubble temperature. The quasisteady one-dimensional model can be extensively used to conduct parametric studies useful for fast estimation of the overall performance of any geometric design. For complex geometry, three-dimensional computational fluid dynamic (CFD) codes are necessary. In the present work good agreements have been found between numerical predictions by the CFD FLUENT code, in which a simplified form of the Rayleigh equation taking into account thermal effects has been implemented by external user routines and some experimental observations.

Author(s):  
Maria Grazia De Giorgi ◽  
Daniela Bello ◽  
Antonio Ficarella

The focus of this research is the experimental and analytical study of the cavitation phenomena in internal flows in presence of thermal effects. Experiments have been done on water and nitrogen cavitating flow in orifices. Transient growth process of the cloud cavitation induced by flow through the throat is observed using high-speed video images and analyzed by pressure signals. Cavitation of thermo-sensible fluid, as cryogenic fluid, presents additional complexities (as compared to that in water) because thermal effects are important. The different cavitating behavior at different temperature and different fluid is related to the bubble dynamic inside the flow. To investigate possible explanations for the influence of fluid temperature on cavitating internal flow, initially, a steady, quasi-one dimensional model has been implemented. The nonlinear dynamics of the bubbles has been modeled by Rayleigh-Plesset equation. In the case of nitrogen, thermal effects in the Rayleigh equation are taken into account by considering the vapor pressure at the actual bubble temperature Tc, which is different from the liquid temperature T far from the bubble. A convective approach has been used to estimate the bubble temperature. The quasi-steady one dimensional model can be extensively used to conduct parametric studies useful for fast estimation of the overall performance of any geometric design. For complex geometry, three-dimensional CFD codes are necessary. In the present work comparison have been done with numerical predictions by the CFD Fluent code in which a simplified form of the Rayleigh equation taking into account thermal effects has been implemented by external user routines.


Author(s):  
Yasmin Khakpour ◽  
Jamal Seyed-Yagoobi

This numerical study investigates the effect of using a blend of micro-encapsulated phase change materials (MEPCMs) on the heat transfer characteristics of a liquid in a rectangular enclosure driven by natural convection. A comparison has been made between the cases of using single component MEPCM slurry and a blend of two-component MEPCM slurry. The natural convection is generated by the temperature difference between two vertical walls of the enclosure maintained at constant temperatures. Each of the two phase change materials store latent heat at a specific range of temperatures. During phase change of the PCM, the effective density of the slurry varies. This results in thermal expansion and hence a buoyancy driven flow. The effects of MEPCM concentration in the slurry and changes in the operating conditions such as the wall temperatures compared to that of pure water have been studied. The MEPCM latent heat and the increased volumetric thermal expansion coefficient during phase change of the MEPCM play a major role in this heat transfer augmentation.


1989 ◽  
Vol 202 ◽  
pp. 83-96 ◽  
Author(s):  
C. Nicoli ◽  
P. Pelcé

We develop a simple model in which longitudinal, compressible, unsteady heat transfer between heater and gas is computed in the small-Mach-number limit. This calculation is used to determine the transfer function of the heater, which plays an important role in the stability limits of the thermoacoustic instability of the Rijke tube. The transfer function is determined analytically in the limit of small expansion parameter γ, and numerically for γ of order unity. In the case ρμ/cp = constant, an analytical solution can be found.


1993 ◽  
Vol 18 ◽  
pp. 161-165 ◽  
Author(s):  
M.R. Albert

Preliminary estimates of the thermal signature of ventilation in polar firn are obtained from two-dimensional numerical calculations. The simulations show that spatially varying surface pressure can induce airflow velocities of 10−5m s−1at 1.5 m depth in uniform firn, and higher velocities closer to the surface. The two-dimensional heat-transfer results generally agree with our earlier one-dimensional conclusions that the thermal effects of ventilation tend to decrease the temperature gradient in the top portions of the pack. Field observations of ventilation through temperature measurements are most likely to be observed when the firn temperature at depths on the order of 10 m is close to the air temperature, since steep temperature gradients can mask the thermal effects of ventilation. Preliminary indications are that, as long as surface-pressure amplitude is sufficient to move the air about in the top tens of centimeters in the snow, the resulting temperature profile during ventilation is fairly insensitive to the frequency of the surface-pressure forcing for pressure frequencies in the range 0.1–10.0 Hz.


Energies ◽  
2019 ◽  
Vol 12 (15) ◽  
pp. 2965 ◽  
Author(s):  
Augusto Della Torre ◽  
Gianluca Montenegro ◽  
Angelo Onorati ◽  
Sumit Khadilkar ◽  
Roberto Icarelli

Plate heat exchangers including offset-strip fins or dimple-type turbulators have a wide application in the automotive field as oil coolers for internal combustion engines and transmissions. Their optimization is a complex task since it requires targeting different objectives: High compactness, low pressure drop and high heat-transfer efficiency. In this context, the availability of accurate Computational Fluid Dynamics (CFD) simulation models plays an important role during the design phase. In this work, the development of a computational framework for the CFD simulation of compact oil-to-liquid heat exchangers, including offset-strip fins and dimples, is presented. The paper addresses the modeling problem at different scales, ranging from the characteristic size of the turbulator geometry (typically µm–mm) to the full scale of the overall device (typically cm–dm). The simulation framework is based on multi-scale concept, which applies: (a) Detailed simulations for the characterization of the micro-scale properties of the turbulator, (b) an upscaling approach to derive suitable macro-scale models for the turbulators and (c) full-scale simulations of the entire cooler, including the porous models derived for the smaller scales. The model is validated comparing with experimental data under different operating conditions. Then, it is adopted to investigate the details of the fluid dynamics and heat-transfer process, providing guidelines for the optimization of the device.


2018 ◽  
Vol 20 (4) ◽  
pp. 393-404 ◽  
Author(s):  
José Galindo ◽  
Roberto Navarro ◽  
Luis Miguel García-Cuevas ◽  
Daniel Tarí ◽  
Hadi Tartoussi ◽  
...  

Zero-dimensional/one-dimensional computational fluid dynamics codes are used to simulate the performance of complete internal combustion engines. In such codes, the operation of a turbocharger compressor is usually addressed employing its performance map. However, simulation of engine transients may drive the compressor to work at operating conditions outside the region provided by the manufacturer map. Therefore, a method is required to extrapolate the performance map to extended off-design conditions. This work examines several extrapolating methods at the different off-design regions, namely, low-pressure ratio zone, low-speed zone and high-speed zone. The accuracy of the methods is assessed with the aid of compressor extreme off-design measurements. In this way, the best method is selected for each region and the manufacturer map is used in design conditions, resulting in a zonal extrapolating approach aiming to preserve accuracy. The transitions between extrapolated zones are corrected, avoiding discontinuities and instabilities.


Author(s):  
Gurveer Singh ◽  
Vishwa Deepak Kumar ◽  
Laltu Chandra ◽  
R. Shekhar ◽  
P. S. Ghoshdastidar

Abstract The open volumetric air receiver (OVAR)-based central solar thermal systems provide air at a temperature > 1000 K. Such a receiver is comprised of porous absorbers, which are exposed to a high heat-flux > 800 Suns (1 Sun = 1 kW/m2). A reliable assessment of heat transfer in an OVAR is necessary to operate such a receiver under transient conditions. Based on a literature review, the need for developing a comprehensive, unsteady, heat transfer model is realized. In this paper, a seven-equations based, one-dimensional, zonal model is deduced. This includes heat transfer in porous absorber, primary-air, return-air, receiver casing, and their detailed interaction. The zonal model is validated with an inhouse experiment showing its predictive capability, for unsteady and steady conditions, within the reported uncertainty of ±7%. The validated model is used for investigating the effect of operating conditions and absorber geometry on the thermal performance of an absorber. Some of the salient observations are (a) the maximum absorber porosity of 70–90% may be preferred for non-volumetric and volumetric-heating conditions, (b) the minimum air-return ratio should be 0.7, and (c) the smallest gap to absorber-length ratio of 0.2 should suffice. Finally, suggestions are provided for extending the model.


Sign in / Sign up