Blade Tip Heat Transfer and Aerodynamics in a Large Scale Turbine Cascade With Moving Endwall

2011 ◽  
Vol 134 (2) ◽  
Author(s):  
P. Palafox ◽  
M. L. G. Oldfield ◽  
P. T. Ireland ◽  
T. V. Jones ◽  
J. E. LaGraff

High resolution Nusselt number distributions were measured on the blade tip surface of a large, 1.0 m chord, low-speed cascade representative of a high-pressure turbine. Data were obtained at a Reynolds number of 4.0×105 based on exit velocity and blade axial chord. Tip clearance levels ranged from 0.56% to 1.68% design span or equally from 1% to 3% of the blade chord. An infrared camera, looking through the hollow blade, made detailed temperature measurements on a constant heat flux tip surface. The relative motion between the endwall and the blade tip was simulated by a moving belt. The moving belt endwall significantly shifts the region of high Nusselt number distribution and reduces the overall averaged Nusselt number on the tip surface by up to 13.3%. The addition of a suction side squealer tip significantly reduced local tip heat transfer and resulted in a 32% reduction in averaged Nusselt number. Analysis of pressure measurements on the blade airfoil surface and tip surface along with particle image velocimetry velocity flow fields in the gap gives an understanding of the heat transfer mechanism.

Author(s):  
P. Palafox ◽  
M. L. G. Oldfield ◽  
P. T. Ireland ◽  
T. V. Jones ◽  
J. E. LaGraff

High resolution Nusselt number (Nu) distributions were measured on the blade tip surface of a large, 1.0 meter-chord, low-speed cascade representative of a high-pressure turbine. Data was obtained at a Reynolds number of 4.0 × 105 based on exit velocity and blade axial chord. Tip clearance levels ranged from 0.56% to 1.68% design span or equally from 1% to 3% of blade chord. An infrared camera, looking through the hollow blade, made detailed temperature measurements on a constant heat flux tip surface. The relative motion between the endwall and the blade tip was simulated by a moving belt. The moving belt endwall significantly to shifts the region of high Nusselt number distribution and reduces the overall averaged Nusselt number on the tip surface by up to 13.3%. The addition of a suction side squealer tip significantly reduced local tip heat transfer and resulted in a 32% reduction in averaged Nusselt number. Analysis of pressure measurements on the blade airfoil surface and tip surface along with PIV velocity flow fields in the gap give an understanding of the heat transfer mechanism.


Author(s):  
Weijie Wang ◽  
Shaopeng Lu ◽  
Hongmei Jiang ◽  
Qiusheng Deng ◽  
Jinfang Teng ◽  
...  

Numerical simulations are conducted to present the aerothermal performance of a turbine blade tip with cutback squealer rim. Two different tip clearance heights (0.5%, 1.0% of the blade span) and three different cavity depths (2.0%, 3.0%, and 6.0% of the blade span) are investigated. The results show that a high heat transfer coefficient (HTC) strip on the cavity floor appears near the suction side. It extends with the increase of tip clearance height and moves towards the suction side with the increase of cavity depth. The cutback region near the trailing edge has a high HTC value due to the flush of over-tip leakage flow. High HTC region shrinks to the trailing edge with the increase of cavity depth since there is more accumulated flow in the cavity for larger cavity depth. For small tip clearance cases, high HTC distribution appears on the pressure side rim. However, high HTC distribution is observed on suction side rim for large tip clearance height. This is mainly caused by the flow separation and reattachment on the squealer rims.


Author(s):  
Knut Lehmann ◽  
Richard Thomas ◽  
Howard Hodson ◽  
Vassilis Stefanis

An experimental study has been conducted to investigate the distribution of the convective heat transfer on the shroud of a high pressure turbine blade in a large scale rotating rig. A continuous thin heater foil technique has been adapted and implemented on the turbine shroud. Thermochromic Liquid Crystals were employed for the surface temperature measurements to derive the experimental heat transfer data. The heat transfer is presented on the shroud top surfaces and the three fins. The experiments were conducted for a variety of Reynolds numbers and flow coefficients. The effects of different inter-shroud gap sizes and reduced fin tip clearance gaps were also investigated. Details of the shroud flow field were obtained using an advanced Ammonia-Diazo surface flow visualisation technique. CFD predictions are compared with the experimental data and used to aid interpretation. Contour maps of the Nusselt number reveal that regions of highest heat transfer are mostly confined to the suction side of the shroud. Peak values exceed the average by as much as 100 percent. It has been found that the interaction between leakage flow through the inter-shroud gaps and the fin tip leakage jets are responsible for this high heat transfer. The inter-shroud gap leakage flow causes a disruption of the boundary layer on the turbine shroud. Furthermore, the development of the large recirculating shroud cavity vortices is severely altered by this leakage flow.


Author(s):  
K. Anto ◽  
S. Xue ◽  
W. F. Ng ◽  
L. J. Zhang ◽  
H. K. Moon

This study focuses on local heat transfer characteristics on the tip and near-tip regions of a turbine blade with a flat tip, tested under transonic conditions in a stationary, 2-D linear cascade with high freestream turbulence. The experiments were conducted at the Virginia Tech transonic blow-down wind tunnel facility. The effects of tip clearance and exit Mach number on heat transfer distribution were investigated on the tip surface using a transient infrared thermography technique. In addition, thin film gages were used to study similar effects in heat transfer on the near-tip regions at 94% height based on engine blade span of the pressure and suction sides. Surface oil flow visualizations on the blade tip region were carried-out to shed some light on the leakage flow structure. Experiments were performed at three exit Mach numbers of 0.7, 0.85, and 1.05 for two different tip clearances of 0.9% and 1.8% based on turbine blade span. The exit Mach numbers tested correspond to exit Reynolds numbers of 7.6 × 105, 9.0 × 105, and 1.1 × 106 based on blade true chord. The tests were performed with a high freestream turbulence intensity of 12% at the cascade inlet. Results at 0.85 exit Mach showed that an increase in the tip gap clearance from 0.9% to 1.8% translates into a 3% increase in the average heat transfer coefficients on the blade tip surface. At 0.9% tip clearance, an increase in exit Mach number from 0.85 to 1.05 led to a 39% increase in average heat transfer on the tip. High heat transfer was observed on the blade tip surface near the leading edge, and an increase in the tip clearance gap and exit Mach number augmented this near-leading edge tip heat transfer. At 94% of engine blade height on the suction side near the tip, a peak in heat transfer was observed in all test cases at s/C = 0.66, due to the onset of a downstream leakage vortex, originating from the pressure side. An increase in both the tip gap and exit Mach number resulted in an increase, followed by a decrease in the near-tip suction side heat transfer. On the near-tip pressure side, a slight increase in heat transfer was observed with increased tip gap and exit Mach number. In general, the suction side heat transfer is greater than the pressure side heat transfer, as a result of the suction side leakage vortices.


Author(s):  
Hongwei Ma ◽  
Jun Zhang ◽  
Jinghui Zhang ◽  
Zhou Yuan

This paper presents an experimental investigation of effects of grooved tip clearances on the flow field of a compressor cascade. The tests were performed in a low-speed large-scale cascade respectively with two tip clearance configurations, including flat tip and grooved tip with a chordwise channel on the blade top. The flow field at 10% chord downstream from the cascade trailing edge was measured at four incidence angles using a mini five-hole pressure probe. The static pressure distribution was measured on the tip endwall. The results show that the pressure gradient from the pressure side to the suction side on the blade tip is reduced due to the existence of the channel. As a result, the leakage flow is weakened. The high-blockage and high-loss region caused by the leakage flow is narrower with the grooved tip. In the meantime, the leakage flow migrates to lower spanwise position. The combined result is that the flow capacity in the tip region is improved at the incidence angles of 0° and 5° with the grooved tip. However, the loss is slightly greater than that with the flat tip at all the incidence angles.


Author(s):  
A. A. Ameri ◽  
E. Steinthorsson ◽  
David L. Rigby

Calculations were performed to assess the effect of the tip leakage flow on the rate of heat transfer to blade, blade tip and casing. The effect on exit angle and efficiency was also examined. Passage geometries with and without casing recess were considered. The geometry and the flow conditions of the GE-E3 first stage turbine, which represents a modern gas turbine blade were used for the analysis. Clearance heights of 0%, 1%, 1.5% and 3% of the passage height were considered. For the two largest clearance heights considered, different recess depths were studied. There was an increase in the thermal load on all the heat transfer surfaces considered due to enlargement of the clearance gap. Introduction of recessed casing resulted in a drop in the rate of heat transfer on the pressure side but the picture on the suction side was found to be more complex for the smaller tip clearance height considered. For the larger tip clearance height the effect of casing recess was an orderly reduction in the suction side heat transfer as the casing recess height was increased. There was a marked reduction of heat load and peak values on the blade tip upon introduction of casing recess, however only a small reduction was observed on the casing itself. It was reconfirmed that there is a linear relationship between the efficiency and the tip gap height. It was also observed that the recess casing has a small effect on the efficiency but can have a moderating effect on the flow underturning at smaller tip clearances.


Author(s):  
F. Casey Wilkins ◽  
Gregory M. Feldman ◽  
Wayne S. Strasser ◽  
James H. Leylek

This work presents a numerical study that was done to investigate the heat transfer characteristics of a transonic turbine blade with a scalloped shroud operating at realistic engine conditions typical of those found in a large scale, land-based gas turbine. The geometry under investigation was an infinite, linear cascade composed of the same blade and shroud design used in an experimental test rig by the research sponsor. This simulation was run for varying nominal tip clearances of 20, 80, and 5.08 mm. For each of these clearances, the simulation was run with and without the scrubbing effects of the outer casing, resulting in a total of six cases that could be used to determine the influence of tip clearance and relative casing motion on heat transfer. A high quality grid (ranging from approximately 10–12 million finite volumes depending on tip clearance) with y+ for first layer cells at or below 1.0 everywhere was used to resolve the flow down to the viscous sublayer. The “realizable” k-ε turbulence model was used for all cases. A constant wall heat flux was imposed on all the surrounding surfaces to obtain heat transfer data. Results produced include a full map of heat transfer coefficients for the suction and pressure surfaces of the blade as well as the tip, shroud, and outer casing for every case. Physical mechanisms responsible for the final heat transfer outcome for all six cases are documented.


2000 ◽  
Vol 123 (4) ◽  
pp. 803-809 ◽  
Author(s):  
Shuye Teng ◽  
Je-Chin Han ◽  
G. M. S. Azad

Measurements of detailed heat transfer coefficient distributions on a turbine blade tip were performed in a large-scale, low-speed wind tunnel facility. Tests were made on a five-blade linear cascade. The low-speed wind tunnel is designed to accommodate the 107.49 deg turn of the blade cascade. The mainstream Reynolds number based on cascade exit velocity was 5.3×105. Upstream unsteady wakes were simulated using a spoke-wheel type wake generator. The wake Strouhal number was kept at 0 or 0.1. The central blade had a variable tip gap clearance. Measurements were made at three different tip gap clearances of about 1.1 percent, 2.1 percent, and 3 percent of the blade span. Static pressure distributions were measured in the blade mid-span and on the shroud surface. Detailed heat transfer coefficient distributions were measured on the blade tip surface using a transient liquid crystal technique. Results show that reduced tip clearance leads to reduced heat transfer coefficient over the blade tip surface. Results also show that reduced tip clearance tends to weaken the unsteady wake effect on blade tip heat transfer.


Author(s):  
Bob Mischo ◽  
Thomas Behr ◽  
Reza S. Abhari

In axial turbine the tip clearance flow occurring in rotor blade rows is responsible for about one third of the aerodynamic losses in the blade row and in many cases is the limiting factor for the blade lifetime. The tip leakage vortex forms when the leaking fluid crosses the gap between the rotor blade tip and the casing from pressure to suction side and rolls up into a vortex on the blade suction side. The flow through the tip gap is both of high velocity and high temperature, with the heat transfer to the blade from the hot fluid being very high in the blade tip area. In order to avoid blade tip burnout and a failure of the machine, blade tip cooling is commonly used. This paper presents the physical study and an improved design of a recessed blade tip for a highly loaded axial turbine rotor blade with application in high pressure axial turbines in aero engine or power generation. With use of three-dimensional Computational Fluid Dynamics (CFD), the flow field near the tip of the blade for different shapes of the recess cavities is investigated. Through better understanding and control of cavity vortical structures, an improved design is presented and the differences to the generic flat tip blade are highlighted. It is observed that by an appropriate profiling of the recess shape, the total tip heat transfer Nusselt Number was significantly reduced, being 15% lower than the flat tip and 7% lower than the baseline recess shape. Experimental results also showed an overall improvement of 0.2% in the one-and-1/2-stage turbine total efficiency with the improved recess design compared to the flat tip case. The CFD analysis conducted on single rotor row configurations predicted a 0.38% total efficiency increase for the rotor equipped with the new recess design compared to the flat tip rotor.


2008 ◽  
Vol 130 (2) ◽  
Author(s):  
Bob Mischo ◽  
Thomas Behr ◽  
Reza S. Abhari

In axial turbine, the tip clearance flow occurring in rotor blade rows is responsible for about one-third of the aerodynamic losses in the blade row and in many cases is the limiting factor for the blade lifetime. The tip leakage vortex forms when the leaking fluid crosses the gap between the rotor blade tip and the casing from pressure to suction side and rolls up into a vortex on the blade suction side. The flow through the tip gap is both of high velocity and of high temperature, with the heat transfer to the blade from the hot fluid being very high in the blade tip area. In order to avoid blade tip burnout and a failure of the machine, blade tip cooling is commonly used. This paper presents the physical study and an improved design of a recessed blade tip for a highly loaded axial turbine rotor blade with application in high pressure axial turbines in aero engine or power generation. With use of three-dimensional computational fluid dynamics (CFD), the flow field near the tip of the blade for different shapes of the recess cavities is investigated. Through better understanding and control of cavity vortical structures, an improved design is presented and its differences from the generic flat tip blade are highlighted. It is observed that by an appropriate profiling of the recess shape, the total tip heat transfer Nusselt number was significantly reduced, being 15% lower than the flat tip and 7% lower than the base line recess shape. Experimental results also showed an overall improvement of 0.2% in the one-and-a-half-stage turbine total efficiency with the improved recess design compared to the flat tip case. The CFD analysis conducted on single rotor row configurations predicted a 0.38% total efficiency increase for the rotor equipped with the new recess design compared to the flat tip rotor.