Phenomenon and Mechanism of Two-Regime-Surge in a Centrifugal Compressor

2015 ◽  
Vol 137 (8) ◽  
Author(s):  
Xinqian Zheng ◽  
Anxiong Liu

“Two-regime-surge” is a special instability behavior of compressors, which was investigated in this paper. When the compressor operates at medium rotor speed, mild surge happens first, where the transient pressure signals show sinusoidal form with Helmholtz frequency of the compressor system. Reducing the mass flow rate, the mild surge vanishes and gets replaced by the local stall. Further reducing the mass flow rate, deep surge breaks out suddenly. During two-regime-surge, two distinct surge patterns exit and vastly narrow stable flow range, which highlights the characteristics of two-regime-surge. It is found that the impeller leading-edge stall is a necessary part of the mild surge, while the diffuser rotating stall incepts the deep surge. At higher speeds, the mild surge oscillation prompts the early occurrence of the diffuser stall so that the mild surge transforms and the deep surge happens in advance. As a result, both regimes of mild surge and deep surge are going to merge, and the stable flow range at high rotational speed is greatly narrowed. Impeller casing treatment is considered as an effective method for flow range extension because the impeller leading-edge stall is removed and the mild surge is avoided as well.

Author(s):  
Byeung Jun Lim ◽  
Tae Choon Park ◽  
Young Seok Kang

In this study, characteristics of stall inception in a single-stage transonic axial compressor with circumferential grooves casing treatment were investigated experimentally. Additionally, the characteristic of increasing irregularity in the pressure inside circumferential grooves as the compressor approaches the stall limit was applied to the stall warning method. Spike-type rotating stall was observed in the single-stage transonic axial compressor with smooth casing. When circumferential grooves were applied, the stall inception was suppressed and the operating point of the compressor moved to lower flow rate than the stall limit. A spike-like disturbance was developed into a rotating stall cell and then the Helmholtz perturbation was overlapped on it at N = 80%. At N = 70 %, the Helmholtz perturbation was observed first and the amplitude of the wave gradually increased as mass flow rate decreased. At N = 60%, spike type stall inceptions were observed intermittently and then developed into continuous rotating stall at lower mass flow rate. Pressure measured at the bottom of circumferential grooves showed that the level of irregularity of pressure increased as flow rate decreased. Based on the characteristic of increasing irregularity of the pressure signals inside the circumferential grooves as stall approaches, an autocorrelation technique was applied to the stall warning. This technique could be used to provide warning against stall and estimate real-time stall margins in compressors with casing treatments.


Author(s):  
Yang Zhao ◽  
Guang Xi ◽  
Jiayi Zhao

The operating range of a centrifugal compressor is often limited by the occurrence of the flow instability, such as diffuser rotating stall or system surge. In the paper, the unsteady numerical simulations are performed on a low-speed centrifugal compressor to investigate the characteristic of the rotating stall in the vaned diffuser. And also, the developed model of lumped parameter is used to predict the system instability. The flow field in the diffuser is firstly investigated at near stall condition. It is found that the leading-edge vortex and the secondary flow induce the hub-corner separation at the suction side of the diffuser blade. When the mass flow rate is reduced gradually, the fore part of the volute turns to act as a diffuser from a nozzle. Under the influence of the asymmetry induced by the volute, the hub-corner separation firstly develops into rotating stall in the passage with the lowest mass flow rate when at critical stall point. And then the diffuser rotating stall propagates along the circumferential direction at about 7% of the impeller speed. And also, the model of lumped parameter considering the effect of rotating stall is developed to analyze the system instability of mild surge. The predicted vibration frequency is within 5.8% of the measurement and the predicted transient process in mild surge matches well with the measurement. With different volume of the compressed air, the transient compressor characteristic tends to be stabilized or oscillates in a cycle along the counter-clockwise with different magnitude.


Author(s):  
Dominik Schlüter ◽  
Robert P. Grewe ◽  
Fabian Wartzek ◽  
Alexander Liefke ◽  
Jan Werner ◽  
...  

Abstract Rotating stall is a non-axisymmetric disturbance in axial compressors arising at operating conditions beyond the stability limit of a stage. Although well-known, its driving mechanisms determining the number of stall cells and their rotational speed are still marginally understood. Numerical studies applying full-wheel 3D unsteady RANS calculations require weeks per operating point. This paper quantifies the capability of a more feasible quasi-2D approach to reproduce 3D rotating stall and related sensitivities. The first part of the paper deals with the validation of a numerical baseline the simplified model is compared to in detail. Therefore, 3D computations of a state-of-the-art transonic compressor are conducted. At steady conditions the single-passage RANS CFD matches the experimental results within an error of 1% in total pressure ratio and mass flow rate. At stalled conditions, the full-wheel URANS computation shows the same spiketype disturbance as the experiment. However, the CFD underpredicts the stalling point by approximately 7% in mass flow rate. In deep stall, the computational model correctly forecasts a single-cell rotating stall. The stall cell differs by approximately 21% in rotational speed and 18% in circumferential size from the experimental findings. As the 3D model reflects the compressor behaviour sufficiently accurate, it is considered valid for physical investigations. In the second part of the paper, the validated baseline is reduced in radial direction to a quasi-2D domain only resembling the compressor tip area. Four model variations regarding span-wise location and extent are numerically investigated. As the most promising model matches the 3D flow conditions in the rotor tip region, it correctly yields a single-cell rotating stall. The cell differs by only 7% in circumferential size from the 3D results. Due to the impeded radial migration in the quasi-2D slice, however, the cell exhibits an increased axial extent. It is assumed, that the axial expansion into the adjacent rows causes the difference in cell speed by approximately 24%. Further validation of the reduced model against experimental findings reveals, that it correctly reflects the sensitivity of circumferential cell size to flow coefficient and individual cell speed to compressor shaft speed. As the approach reduced the wall clock time by 92%, it can be used to increase the physical understanding of rotating stall at much lower costs.


Author(s):  
Saad A. Ahmed

Centrifugal compressors or blowers are widely used in many industrial applications. However, the operation of such systems is limited at low-mass flow rates by self-excited flow instabilities which could result in rotating stall or surge of the compressor. These instabilities will limit the flow range in which the compressor or the blower can operate, and will also lower their performance and efficiency. Experimental techniques were used to investigate a model of radial vaneless diffuser at stall and stall-free operating conditions. The speed of the impeller was kept constant, while the mass flow rate was reduced gradually to study the steady and unsteady operating conditions of the compressor. Additional experiments were made to investigate the effects of reducing the exit flow area on the inception of stall. The results indicate that the instability in the diffuser was successfully delayed to a lower flow coefficient when throttle rings were attached to either one or both of the diffuser walls (i.e., to reduce the diffuser exit flow area). The results also showed that an increase of the blockage ratio improves the stability of the system (i.e., the critical mass flow rate could be reduced to 50% of its value without blockage). The results indicate that the throttle rings could be an effective method to control stall in radial diffusers.


2014 ◽  
Vol 30 (3) ◽  
pp. 307-313 ◽  
Author(s):  
R. Taghavi-Zenou ◽  
S. Abbasi ◽  
S. Eslami

ABSTRACTThis paper deals with tip leakage flow structure in subsonic axial compressor rotor blades row under different operating conditions. Analyses are based on flow simulation utilizing computational fluid dynamic technique. Three different circumstances at near stall condition are considered in this respect. Tip leakage flow frequency spectrum was studied through surveying instantaneous static pressure signals imposed on blades surfaces. Results at the highest flow rate, close to the stall condition, showed that the tip vortex flow fluctuates with a frequency close to the blade passing frequency. In addition, pressure signals remained unchanged with time. Moreover, equal pressure fluctuations at different passages guaranteed no peripheral disturbances. Tip leakage flow frequency decreased with reduction of the mass flow rate and its structure was changing with time. Spillage of the tip leakage flow from the blade leading edge occurred without any backflow in the trailing edge region. Consequently, various flow structures were observed within every passage between two adjacent blades. Further decrease in the mass flow rate provided conditions where the spilled flow ahead of the blade leading edge together with trailing edge backflow caused spike stall to occur. This latter phenomenon was accompanied by lower frequencies and higher amplitudes of the pressure signals. Further revolution of the rotor blade row caused the spike stall to eventuate to larger stall cells, which may be led to fully developed rotating stall.


2012 ◽  
Vol 224 ◽  
pp. 352-357
Author(s):  
Islem Benhegouga ◽  
Ce Yang

In this work, steady air injection upstream of the blade leading edge was used in a transonic axial flow compressor, NASA rotor 37. The injectors were placed at 27 % upstream of the axial chord length at blade tip, the injection mass flow rate is 3% of the chock mass flow rate, and 3 yaw angles were used, respectively -20°, -30°, and -40°. Negative yaw angles were measured relative to the compressor face in opposite direction of rotational speeds. To reveal the mechanism, steady numerical simulations were performed using FINE/TURBO software package. The results show that the stall mass flow can be decreased about 2.5 %, and an increase in the total pressure ratio up to 0.5%.


1988 ◽  
Author(s):  
M. V. Otugen ◽  
R. M. C. So ◽  
B. C. Hwang

Experiments were carried out in a model vaneless diffuser rig to investigate the rotating stall phenomenon and its relation to diffuser geometry. The experimental rig consisted of an actual impeller which was used to deliver the flow to the vaneless diffuser. Mass flow rate through the system could be adjusted by varying the rotational speed of the impeller at a fixed inlet opening or by changing the inlet opening at a fixed impeller speed. The flow exited to room condition. As such, the rig was designed to investigate the fluid mechanics of vaneless diffuser rotating stall only. Attention was focused on the effects of diffuser width and radius on rotating stall. Three diffuser widths and three outlet radii were examined. The width-to-inlet radius ratio varied between 0.09 and 0.142 while the outlet-to-inlet radius ratio varied between 1.5 and 2. Results showed that the critical mass flow rate for the onset of rotating stall decreases with decreasing diffuser width. The critical mass flow rate is affected also by the diffuser radius ratio; larger radius ratios resulted in smaller critical mass flow rates. The ratio of the speed of rotation of the stall cell to impeller speed is found to decrease with increasing number of stall cells. This relative speed also decreases with increasing diffuser radius ratio, but it is largely independent of the diffuser width.


Author(s):  
Mingmin Zhu ◽  
Xiaoqing Qiang ◽  
Wensheng Yu ◽  
Jinfang Teng

The purpose of this work is to understand the properties of the injection flow through slots opening surfaces with steady and unsteady simulations. The feasibility of evaluating slot effectiveness by steady results is demonstrated. Transient features of injection flow are detailed investigated. Numerical investigations are carried out in a 1.5 axial transonic compressor stage at a specified rotating speed with seven kinds of slot-type casing treatments. Comparisons between steady/unsteady results show that differences of overall performance and injection mass flow rate are dependent on simulation methods, rather than slot configurations. Thus, correlation analysis by steady results of seven slot configurations is considered valid and reveals strong linear correlation between injection mass flow and stall margin improvements/efficiency drops. Therefore, it is practical to evaluate the effectiveness of a specific slot configuration in this compressor with steady results by calculating injection mass flow rate. Afterwards, unsteady simulations are performed with a specific configuration of arc-curve skewed slots. It is clarified that the dividing locations between suction/injection regions moves along the axial direction based on the relative rotor/slots location. Exchanging flow through slots opening surfaces displays periodic variations over time. The variation cycle for one single slot equals blade passing period T. For summation of mass flow through all slots, the cycle equals to T divided by slots number in one passage. The net flow rate through all opening surfaces is always less than zero during a blading passing period, i.e. injection mass flow rate is larger than suction flow all the time.


2021 ◽  
Vol 2130 (1) ◽  
pp. 012031
Author(s):  
W Stryczniewicz ◽  
W Stalewski

Abstract The paper presents a test stand for characterization of a new design of a Pulsed Jet Actuator. The aim of the work was to characterize the performance of the PJA in terms of air parameters in the air supply line and velocity at the PJA outlet. To perform a detailed characterization of the system performance, the test bench comprised: a pressure reductor, a mass flow rate controller, a mass flow rate meter, a pressure sensor, a fast pressure sensor, a flow temperature sensor and a Constant Temperature Anemometer. The PJA was commanded by a real time controller with Field Programmed Gate Array architecture. The experimental results show good agreement with the results of Computational Fluid Dynamics simulations performed at the design stage of the PJA. It has been found that the flow parameters at the PJA nozzle outlet match the design goals. The developed bench testing procedures will be used for silent conditions tests of the PJA system integrated into a leading edge of a wind tunnel model.


1988 ◽  
Author(s):  
Katerina Nácovská

An experimental investigation of rotating stall and surge was carried out on a four stage axial flow compressor. Results of flow and blade temperature measurements in the compressor are presented. Internal temperature levels during rotating stall and surge are considerably higher than those obtained during unstalled compressor operation. In the pure rotating stall regime, the temperature is almost identical in all compressor stages and depends only on rotor speed and mass flow rate. During surge, the highest temperature is found at the tip diameter prior to the first stage rotor. The absolute level depends on rotor speed, mass flow rate (i.e. throttle position) and on the number of compressor stages. A model of the temperature changes in the multistage compressor during the surge cycle has been derived from the experiments.


Sign in / Sign up

Export Citation Format

Share Document