Influence of Rotor Tip Blockage on Near Stall Blade Vibrations in an Axial Compressor Rig

2017 ◽  
Vol 140 (2) ◽  
Author(s):  
Daniel Möller ◽  
Maximilian Jüngst ◽  
Heinz-Peter Schiffer ◽  
Thomas Giersch ◽  
Frank Heinichen

Rotor blade vibrations observed in the Darmstadt transonic compressor rig are investigated in this paper. The vibrations are nonsynchronous and occur in the near stall (NS) operating region. Rotor tip flow fluctuations traveling near the leading edge (LE) against the direction of rotation (in the rotor relative frame of reference) with about 50% blade tip speed are found to be the reason for the occurrence of the vibrations. The investigations show that the blockage at the rotor tip is an important factor for the aeroelastic stability of the compressor in the NS region. It is found that by application of a recirculating tip injection (TI) casing treatment, the aeroelastic stability increases as a result of reduced blockage in the rotor tip region.

Author(s):  
Daniel Möller ◽  
Maximilian Jüngst ◽  
Heinz-Peter Schiffer ◽  
Thomas Giersch ◽  
Frank Heinichen

Rotor blade vibrations observed in the Darmstadt transonic compressor rig are investigated in this paper. The vibrations are non-synchronous and occur in the near stall operating region. Rotor tip flow fluctuations traveling near the leading edge against the direction of rotation (in the rotor relative frame of reference) with about 50% blade tip speed are found to be the reason for the occurrence of the vibrations. The investigations show, that the blockage at the rotor tip is an important factor for the aeroelastic stability of the compressor in the near stall region. It is found, that by application of a recirculating tip injection casing treatment, the aeroelastic stability increases as a result of reduced blockage in the rotor tip region.


Author(s):  
HaoGuang Zhang ◽  
Feng Tan ◽  
YanHui Wu ◽  
WuLi Chu ◽  
Wei Wang ◽  
...  

For compressor blade tip stall, one effective way of extending stable operating range is with the application of circumferential grooved casing treatment and its validity was proved by a lot of experimental and numerical investigations. The emphases of most circumferential grooved investigations are focused on the influence of groove depth and groove number on compressor stability, and there is few investigations dealt with the center offset degree of circumferential grooves casing treatment. Hence, an axial compressor rotor with casing treatment (CT) was investigated with experimental and numerical methods to explore the effect of center offset degree on compressor stability and performance. In the work reported here, The center offset degree is defined as the ratio of the central difference between rotor tip axial chord and CT to the axial chord length of rotor tip. When the center of CT is located within the upstream direction of the center of rotor tip axial chord, the value of center offset degree is positive. The experimental and numerical results show that stall margin improvement gained with CT is reduced as the value of center offset degree varies from 0 to 0.33 or −0.33, and the CT with −0.33 center offset degree achieves the lowest value of stall margin improvement at 53% and 73% design rotational speed. The detailed analysis of the flow-field in compressor tip indicates that there is not positive effect made by grooves on leading edge of rotor blade tip when the value of center offset degree is −0.33. As the mass flow of compressor reduces further, tip clearance leakage flow results in the outlet blockage due to the absence of the positive action of grooves near blade tip tail when the value of center offset degree is 0.33. Blockage does not appear in rotor tip passage owing to utilizing the function of all grooves with CT of 0 center offset degree.


Author(s):  
R. Schnell ◽  
M. Voges ◽  
R. Mo¨nig ◽  
M. W. Mu¨ller ◽  
C. Zscherp

A single-stage transonic axial compressor was equipped with a casing treatment, consisting of 3.5 axial slots per rotor pitch in order to investigate its influence on stall margin characteristics as well as on the rotor near tip flowfield both numerically and experimentally. Contrary to most other studies a generic Casing Treatment was designed to provide optimal optical access in the immediate vicinity of the CT, rather than for maximum benefit in terms of stall margin extension. The second part of this two-part paper deals with the numerical developments, and their validation, carried out in order to efficiently perform time-accurate casing-treatment simulations. The numerical developments focus on the extension of an existing coupling algorithm in order to carry out unsteady calculations with any exterior geometry coupled to the main flow passage (in this case a single slot) having an arbitrary pitch. This extension is done by incorporating frequency domain, phase-lagged boundary conditions into this coupling procedure. Whereas the phaselag approach itself is well established and validated for standard rotor-stator calculations, its application to casing treatment simulations is new. Its capabilities and validation will be demonstrated on the given compressor configuration, making extensive use of the detailed PIV flowfield measurements near the rotor tip. Instantaneous data at all measurement planes will be compared for different rotor positions with respect to the stationary slots in order to evaluate the time-dependent interaction between the rotor and the casing treatment.


Author(s):  
B. H. Beheshti ◽  
B Farhanieh ◽  
K Ghorbanian ◽  
J. A. Teixeira ◽  
P. C. Ivey

The casing treatment and flow injection upstream of the rotor tip are two effective approaches in suppressing instabilities or recovering from a fully developed stall. This paper presents numerical simulations for a high-speed transonic compressor rotor, NASA Rotor 37, applying a state-of-the-art design for the blade tip injection. This is characterized by introducing a jet flow directly into the casing treatment machined into the shroud. The casing treatment is positioned over the blade tip region and exceeds the impeller axially by ∼30 per cent of the tip chord both in the upstream and in the downstream directions. To numerically solve the governing equations, the three-dimensional finite element based finite volume method CFD solver CFX-TASCflow (version 2.12.1) is employed. For a compressible flow with varying density, Reynolds-averaging leads to appearance of complicated correlations. To avoid this, the mass-weighted or Favre-averaging is applied. Using an injected mass flow of 2.4 per cent of the annulus flow, the present design can improve stall margin by up to 7 per cent when compared with a smooth casing compressor without tip injection. This research can lead to an optimum design of recirculating casing treatments or other mechanisms for performance enhancement applying tip flow injection.


Author(s):  
Song Yan ◽  
Wuli Chu

The performance curve of the compressor is limited by the surge boundary, so it is of great significance to increase the stable working range of the compressor. The self-circulating casing treatment is an effective way to improve the stable working range of the compressor. In this paper, the study of the influence of the injector position of the self-circulating casing treatment on the transonic axial flow compressor rotor performance is carried out by using the numerical simulation. The influence mechanism of the injector position on the enhancing stability effect of the self-circulating casing treatment is revealed. It is found that the self-circulating casing treatment can reduce the blade tip blockage by restraining the blade tip clearance leakage flow and changing the trajectory of the tip clearance leakage vortex, thus delaying the deterioration of the rotor tip flow field and improving the rotor stability. When the injector position of the self-circulating casing treatment moves from the upstream of the leading edge of the blade tip to the trailing edge of the blade tip, the enhancing stability effect of the self-circulating casing treatment increases first and then decreases. But the high-velocity jet from the injector of the self-circulating casing treatment aggravates the mixing loss of the rotor tip flow field, so that the rotor efficiency slightly decreases after using the self-circulating casing treatment.


Author(s):  
D. C. Rabe ◽  
C. Hah

Experimental and numerical investigations were conducted to study the fundamental flow mechanisms of circumferential grooves in the casing of a transonic compressor and their influence on compressor stall margin. Three different groove configurations were tested in a highly loaded transonic compressor. Experimental results show that circumferential grooves increase the stall margin of the compressor at the tested operating condition. Grooves with a much smaller depth than conventional designs are shown to be similarly effective in increasing the stall margin. Steady-state Navier-Stokes analyses were performed to study flow structures associated with each casing treatment. The numerical procedure calculates the overall effects of the circumferential grooves correctly. Detailed investigation of calculated flow fields indicates that losses are generated by interaction between the main passage flow and flow exiting the grooves. The grooves increase the stall margin by reducing the flow incidence angle on the pressure side of the leading edge, despite an overall increase in the endwall boundary layer thickness. This is due to complex interaction of the main passage flow with the additional radial and tangential flows created by the grooves.


2016 ◽  
Vol 139 (2) ◽  
Author(s):  
Cyril Guinet ◽  
André Inzenhofer ◽  
Volker Gümmer

The design space of axial-flow compressors is restricted by stability issues. Different axial-type casing treatments (CTs) have shown their ability to enhance compressor stability and to influence efficiency. Casing treatments have proven to be effective, but there still is need for more detailed investigations and gain of understanding for the underlying flow mechanism. Casing treatments are known to have a multitude of effects on the near-casing 3D flow field. For transonic compressor rotors, these are more complex, as super- and subsonic flow regions alternate while interacting with the casing treatment. To derive design rules, it is important to quantify the influence of the casing treatment on the different tip flow phenomena. Designing a casing treatment in a way that it antagonizes only the deteriorating secondary flow effects can be seen as a method to enhance stability while increasing efficiency. The numerical studies are carried out on a tip-critical rotor of a 1.5-stage transonic axial compressor. The examined recirculating tip blowing casing treatment (TBCT) consists of a recirculating channel with an air off-take above the rotor and an injection nozzle in front of the rotor. The design and functioning of the casing treatment are influenced by various parameters. A variation of the geometry of the tip blowing, more specifically the nozzle aspect ratio, the axial position, or the tangential orientation of the injection port, was carried out to identify key levers. The tip blowing casing treatment is defined as a parameterized geometric model and is automatically meshed. A sensitivity analysis of the respective design parameters of the tip blowing is carried out on a single rotor row. Their impact on overall efficiency and their ability to improve stall margin are evaluated. The study is carried out using unsteady Reynolds-averaged Navier–Stokes (URANS) simulations.


Author(s):  
Kirubakaran Purushothaman ◽  
Sankar Kumar Jeyaraman ◽  
Ajay Pratap ◽  
Kishore Prasad Deshkulkarni

This study discusses in detail the aeroelastic flutter investigation of a transonic axial compressor rotor using computational methods. Fluid structure interaction approach is used in this method to evaluate the unsteady aerodynamic force and work done of a vibrating blade in CFD domain. Energy method and work per cycle approach is adapted for this flutter prediction. A framework has been developed to estimate the work per cycle and aerodynamic damping ratio. Based on the aerodynamic damping ratio, occurrence of flutter is estimated for different inter blade phase angles. Initially, the baseline rotor blade design was having negative aerodynamic damping at part speed conditions. The main cause for this flutter occurrence was identified as large flow separation near blade tip region due to high incidence angles. The unsteadiness in the flow was leading to aerodynamic force fluctuation matching with natural frequency of blade, resulting in excitation of the blades. Hence axially skewed slot casing treatment was implemented to reduce the flow separation at blade tip region to alleviate the onset of flutter. By this method, the stall margin and aerodynamic damping of the test compressor was improved and flutter was avoided.


Author(s):  
Hongwei Ma ◽  
Jun Zhang

The purpose of this paper is to investigate numerically the effects of the tip geometry on the performance of an axial compressor rotor. There are three case studies which are compared with the base line tip geometry. 1) baseline (flat tip); 2) Cavity (tip with a cavity); 3) SSQA (suction side squealer tip) and 4) SSQB (modified suction side squealer tip). The case of SSQB is a combination of suction side squealer tip and the cavity tip. From leading edge to 10% chord, the tip has a cavity. From 10% chord to trailing edge, the tip has a suction side squealer. The numerical results of 2) show that the cavity tip leads to lower leakage mass flow and greater loss in tip gap and the rotor passage. The loading near the blade tip is lower than the baseline, thus the tangential force of the blade is lower. It leads to lower pressure rise than the baseline. The performance of the compressor for the tip with cavity is worse than the baseline. The results of 3) show that the higher curvature of the suction side squealer increases the loading of the blade and the tangential blade force. With the suction side squealer tip, the leakage flow experiences two vena contractor thus the mass of the leakage flow is reduced which is benefit for the performance of the compressor. The loss in the tip gap is lower than baseline. The performance is better than the baseline with greater pressure rise of the rotor, smaller leakage mass flow and lower averaged loss. For the case the SSQB, the leakage mass flow is lower than the SSQA and the loss in the tip gap and the rotor passage is greater than SSQA. The performance of the case of the SSQB is worse than the case of SSQA.


Author(s):  
Yiming Zhong ◽  
WuLi Chu ◽  
HaoGuang Zhang

Abstract Compared to the traditional casing treatment, the self-recirculating casing treatment (SCT) can improve or not decrease the compressor efficiency while achieving the stall margin improvement. For the bleed port, the main design indicator is to reduce the flow loss caused by suction, while providing sufficient jet flow and jet pressure to the injector. In order to gain a better study of the bleed port stabilization mechanisms, the bleed configuration was parameterized with the bleed port inlet width and the bleed port axial position. Five kinds of recirculating casing treatments were applied to a 1.5-stage transonic axial compressor with the method of three-dimensional unsteady numerical simulation. Fifteen identical self-recirculating devices are uniformly mounted around the annulus. The numerical results show that the SCT can improve compressor total pressure ratio and stability, shift the stall margin towards lower mass flows. Furthermore, it has no impact on compressor efficiency. The optimal case presents that stability margin is improved by 6.7% employing 3.1% of the annulus mass flow. Expanding bleed port inlet width to an intermediate level can further enhance compressor stability, but excessive bleed port inlet width will reduce the stabilization effect. The optimal bleed port position is located in the blocked area of the low energy group at the top of the rotor. In the case of solid casing, stall inception was the tip blockage, which was mainly triggered by the interaction of the tip leakage vortex and passage shock. From radial distribution, the casing treatment predominantly affects the above 70% span. The reduction of tip reflux region by suction effect is the main reason for the extension of stable operation range. The SCT also has an obvious stability improvement in tip blockage stall, while delaying the occurrence of compressor stall.


Sign in / Sign up

Export Citation Format

Share Document