An Improved Methodology to Design Large-Scale Photovoltaic Power Plant

2017 ◽  
Vol 140 (1) ◽  
Author(s):  
Ali Durusu ◽  
Ali Erduman

A secure and reliable supply of energy is important for economic stability and even in social life. Increasing human population, industrialization, and rising living standards lead to increased electrical energy demand. Uncertainties in oil prices, shortage of fossil fuel reserves, and environmental pollution from conventional fuels leads solar energy as an alternative resource for electricity production. The share of installed photovoltaic (PV) capacity as a percent of total installed power generating capacity is increasing every year. In this study, an improved methodology to design large-scale PV power plant is proposed. The proposed methodology is performed for designing optimal configurations of PV power plants. The design methodology is performed using commercially available PV modules and inverters. In addition, solar radiation, ambient temperature, wind speed, shadow effect, and location and shape of plant field are taken into consideration as input parameters. The alternatives and parameters are evaluated with the purpose of minimizing the levelized cost of generated electricity (LCOE). The methodology includes the use of a genetic algorithm (GA) for determining the optimal number of PV modules and inverters, optimum tilt angle of PV modules, required installation area for the plant and optimum cable cross section and lengths. In the paper, the methodology is implemented, and case studies and results using pvsyst software for the same case studies are compared with each other.

2015 ◽  
Vol 10 (2) ◽  
pp. 414-421
Author(s):  
Bahareh Hashemlou ◽  
Hossein Sadeghi ◽  
Arashk Masaeli ◽  
Mohammadhadi Hajian ◽  
Shima Javaheri

Organizations, institutions, and different sectors of manufacturing, services and agriculture are constantly making decisions. Each of the aforementioned sectors, have strategies, tactics, and various functions that play a basic role in reaching the objectives. On the other hand, energy demand in developing countries is increasing day by day. The exact calculation of the cost per unit of electricity generated by power plants is not easy. Therefore, this study according to four sources of natural gas, nuclear energy, renewable energy and other fossil fuels other than natural gas that are used in a variety of electricity production plants is trying to clarify the ranking of generation electricity approach using "fuzzy preference relations" analysis. Accordingly, three models were used and the results showed that natural gas, with regard to the four criteria of low investment cost, low power, lack of pollution and the safety and reliability of electrical energy has priority over other alternatives. Full preferred model results also suggested that the energy of natural gas, renewable energies, nuclear and other fossil fuels should be considered in a priority for power generation. Sensitivity analysis results moreover demonstrated that the above models are not affected by the threshold values ​​and the full stability of the models is observed.


2006 ◽  
Vol 10 (3) ◽  
pp. 71-80
Author(s):  
Nikolaos Koukouzas ◽  
Paraskevas Klimantos ◽  
Prokopis Stogiannis ◽  
Emmanouel Kakaras

The aim of this paper is to examine the possibilities for the abatement of CO2 emissions in the Greek fossil fuel power generation sector. An overview of CO2 capture, transportation, and storage concepts, on which the R&D community is focused, is presented. The implementation of post-combustion CO2 capture options in an existing fossil fuel power plant is then examined and the consequences on the overall plant performance are determined. Finally, the possibilities of transportation and then underground storage of the pure CO2 stream are analyzed taking into account both technical and economical factors. The results of this analysis show that CO2 sequestration is technically feasible for existing fossil fuel fired power plants in Greece. However, substantial reduction in plant efficiency is observed due to increased energy demand of the technologies used as well as in electricity production cost due to capital and operation costs of capture, transport, and storage of CO2. .


Author(s):  
Jurij Avsec ◽  
Peter Virtic´ ◽  
Tomazˇ Zˇagar ◽  
Luka Sˇtrubelj

Efficient and sustainable methods of clean fuel and energy production are needed in all countries of the world in the face of depleting oil reserves and the need to reduce carbon dioxide emissions. Some countries are developing technologies that could be named zero carbon technologies. The presented article will show how hydrogen technologies could be implemented with renewable technologies and nuclear technology. Nuclear technology produce very cheap electricity and could produce also cheap energy like heat and vapour. This technology should be used in nuclear power plants to develop other products like hydrogen, biofuels or district heating. One of the biggest opportunities for nuclear energy technology is to produce hydrogen. Some countries like Canada and US are in preparation to build hydrogen villages. However, a key missing element is a large-scale method of hydrogen production [1–5]. As a carbon-based technology, the predominant existing process (steam-methane reforming (SMR)) is unsuitable. This paper focuses on a production of hydrogen in connection with a nuclear power plant. We will show the technologies which allow the coupling between a nuclear power plant and hydrogen technologies.


Energies ◽  
2021 ◽  
Vol 14 (19) ◽  
pp. 6213
Author(s):  
Saud Alotaibi ◽  
Ahmed Darwish

The use of photovoltaic (PV) systems as the energy source of electrical distributed generators (DG) is gaining popularity, due to the progress of power electronics devices and technologies. Large-scale solar PV power plants are becoming the preferable solution to meet the fast growth of electrical energy demand, as they can be installed in less than one year, as compared to around four years in the case of conventional power plants. Modular multilevel inverters (MMIs) are the best solution to connect these large-scale PV plants to the medium-voltage (MV) grid, due to their numerous merits, such as providing better power quality, having higher efficiency, providing better reliability, and their scalability. However, MMIs are still progressing and need some improvement before they can be implemented safely in the industrial, medium, and high voltage networks. The main purpose of this paper is to review the present MMIs topologies when used in PV applications. The review aims to present a comprehensive study of the various recent submodule circuits associated with MMI topologies. Maximum power point tracking (MPPT) control schemes for PV inverters will be explored extensively. Then, the different control strategies of PV MMIs will be presented and compared to give a holistic overview of the submodules balancing techniques, ranges, and capabilities under balanced and unbalanced grid conditions. In addition, the paper will discuss the future of PV MMIs systems in electricity networks.


2020 ◽  
Vol 39 (5) ◽  
pp. 6339-6350
Author(s):  
Esra Çakır ◽  
Ziya Ulukan

Due to the increase in energy demand, many countries suffer from energy poverty because of insufficient and expensive energy supply. Plans to use alternative power like nuclear power for electricity generation are being revived among developing countries. Decisions for installation of power plants need to be based on careful assessment of future energy supply and demand, economic and financial implications and requirements for technology transfer. Since the problem involves many vague parameters, a fuzzy model should be an appropriate approach for dealing with this problem. This study develops a Fuzzy Multi-Objective Linear Programming (FMOLP) model for solving the nuclear power plant installation problem in fuzzy environment. FMOLP approach is recommended for cases where the objective functions are imprecise and can only be stated within a certain threshold level. The proposed model attempts to minimize total duration time, total cost and maximize the total crash time of the installation project. By using FMOLP, the weighted additive technique can also be applied in order to transform the model into Fuzzy Multiple Weighted-Objective Linear Programming (FMWOLP) to control the objective values such that all decision makers target on each criterion can be met. The optimum solution with the achievement level for both of the models (FMOLP and FMWOLP) are compared with each other. FMWOLP results in better performance as the overall degree of satisfaction depends on the weight given to the objective functions. A numerical example demonstrates the feasibility of applying the proposed models to nuclear power plant installation problem.


Energies ◽  
2021 ◽  
Vol 14 (7) ◽  
pp. 1988
Author(s):  
Ioannis E. Kosmadakis ◽  
Costas Elmasides

Electricity supply in nonelectrified areas can be covered by distributed renewable energy systems. The main disadvantage of these systems is the intermittent and often unpredictable nature of renewable energy sources. Moreover, the temporal distribution of renewable energy may not match that of energy demand. Systems that combine photovoltaic modules with electrical energy storage (EES) can eliminate the above disadvantages. However, the adoption of such solutions is often financially prohibitive. Therefore, all parameters that lead to a functionally reliable and self-sufficient power generation system should be carefully considered during the design phase of such systems. This study proposes a sizing method for off-grid electrification systems consisting of photovoltaics (PV), batteries, and a diesel generator set. The method is based on the optimal number of PV panels and battery energy capacity whilst minimizing the levelized cost of electricity (LCOE) for a period of 25 years. Validations against a synthesized load profile produced grid-independent systems backed by different accumulator technologies, with LCOEs ranging from 0.34 EUR/kWh to 0.46 EUR/kWh. The applied algorithm emphasizes a parameter of useful energy as a key output parameter for which the solar harvest is maximized in parallel with the minimization of the LCOE.


Atmosphere ◽  
2021 ◽  
Vol 12 (7) ◽  
pp. 811
Author(s):  
Yaqin Hu ◽  
Yusheng Shi

The concentration of atmospheric carbon dioxide (CO2) has increased rapidly worldwide, aggravating the global greenhouse effect, and coal-fired power plants are one of the biggest contributors of greenhouse gas emissions in China. However, efficient methods that can quantify CO2 emissions from individual coal-fired power plants with high accuracy are needed. In this study, we estimated the CO2 emissions of large-scale coal-fired power plants using Orbiting Carbon Observatory-2 (OCO-2) satellite data based on remote sensing inversions and bottom-up methods. First, we mapped the distribution of coal-fired power plants, displaying the total installed capacity, and identified two appropriate targets, the Waigaoqiao and Qinbei power plants in Shanghai and Henan, respectively. Then, an improved Gaussian plume model method was applied for CO2 emission estimations, with input parameters including the geographic coordinates of point sources, wind vectors from the atmospheric reanalysis of the global climate, and OCO-2 observations. The application of the Gaussian model was improved by using wind data with higher temporal and spatial resolutions, employing the physically based unit conversion method, and interpolating OCO-2 observations into different resolutions. Consequently, CO2 emissions were estimated to be 23.06 ± 2.82 (95% CI) Mt/yr using the Gaussian model and 16.28 Mt/yr using the bottom-up method for the Waigaoqiao Power Plant, and 14.58 ± 3.37 (95% CI) and 14.08 Mt/yr for the Qinbei Power Plant, respectively. These estimates were compared with three standard databases for validation: the Carbon Monitoring for Action database, the China coal-fired Power Plant Emissions Database, and the Carbon Brief database. The comparison found that previous emission inventories spanning different time frames might have overestimated the CO2 emissions of one of two Chinese power plants on the two days that the measurements were made. Our study contributes to quantifying CO2 emissions from point sources and helps in advancing satellite-based monitoring techniques of emission sources in the future; this helps in reducing errors due to human intervention in bottom-up statistical methods.


2018 ◽  
Vol 9 (1) ◽  
pp. 1-7
Author(s):  
Redaksi Tim Jurnal

PT PJB Muara Karang power plant is an industry with a large electrical energy consumption for auxiliary power. In ISO50001 itensitas Energy Consumption (IKE) is a great need to audit energy consumption. In the contract the company's performance also set a percentage of personal use should not exceed 6% of the electricity production. Currently Posentase usage of own consumption at power plant unit 5 is greater than the power plant unit 4. It is necessary for an energy audit for the usage of its own in order to decrease the percentage of personal use in the power plant 5 0.5% of the current conditions and find energy savings opportunities in the power plant unit 5.To analyze this problem using energy audits, analyzes the performance test method using "gate cycle" and testing the quality of the voltage source by using the power quality measurement analysis. Having found the equipment with the largest energy comsumtion fish bone tools used to find the main cause of this disorder.


ijd-demos ◽  
2020 ◽  
Vol 2 (2) ◽  
Author(s):  
Nida Urrohmah ◽  
Karin Caroline Kelly ◽  
Fitri Yuliani

Electric Steam Power Plants (PLTU) need coal as fuel to produce electricity. The higher the electrical energy needed to eat, the more fuel will be used. This has happened in the construction of shelters 9 and 10 Suralaya Merak-Banten steam power plant (PLTU). This development is reaping various kinds of rejection because it causes environmental damage not only in the area around the development operation but also in the Greater Jakarta area. The rejection movement was initiated by local residents and supported by international Environmental NGOs.Pembangkit Listrik Tenaga Uap (PLTU) membutuhkan batu bara sebagai bahan bakar untuk menghasilkan energi listrik. Semakin tinggi energi listrik yang dibutuhkan makan akan semakin banyak bahan bakar yang digunakan. Hal ini terjadi pada pembangunan shelter 9 dan 10 PLTU Suralaya di pulau Jawa spesifiknya di daerah Merak-Banten. Pembangunan ini menuai berbagai macam penolakan karena mengakibatkan kerusakan lingkungan tidak hanya pada wilayah sekitar operasi pembangunan namun juga pada wilayah Jabodetabek. Gerakan penolakan diinisiasi tentunya oleh warga setempat dan didukung dengan NGO Internasional penggiat isu lingkungan. 


Author(s):  
Bima Sakti ◽  
Nur Rani Alham ◽  
Ahmad Nur Fajri ◽  
Ilham Rizal Ma’rif

<em>The need for electricity in Indonesia is very important considering the limited resources and the lack of manpower, making Indonesia desperately need to increase electricity generation. One source of energy that can be converted into electrical energy is tidal barrage using the tidal barrage method. The application of this energy is still very small in Indonesia but there are a number of areas that have the potential to be implemented by the power plant. Tidal power plants that utilize the potential energy contained in the differences in tides and tides of sea water by trapping water in dams and then moving water turbines and when the water turbine is connected to a generator can produce electrical energy. Related to how the output of the generated power can it is known by looking at what height the water level drives the turbine. This type of power plant is environmentally friendly because it does not damage the natural ecosystem and the dam can be used for various activities.</em><em></em>


Sign in / Sign up

Export Citation Format

Share Document