Physics of Failure-Based Reliability Assessment for Systems Exposed to Sliding Wear Under Uncertainty

Author(s):  
Mohammad Pourmostafaei ◽  
Mohammad Pourgol-Mohammad ◽  
Mojtaba Yazdani ◽  
Hossein Salimi

Abstract In this paper, a new model is proposed for system degradation evaluation under sliding wear failure mechanism. This model estimates the material loss with respect to progression of sliding distance. This model is generated by considering physical and geometrical aspects of the system which is under wear failure mechanism. Several sets of experimental data are used for validation of the presented model. These experimental data are related to the pin-on-disk test including initially conformal and nonconformal contacts. A dataset of the pin-on-disk test by ASTM-G99 standard is used for additional model validation. The rail system data are employed for validation of the model in the practical systems. Uncertainty is analyzed by Monte Carlo simulation to determine the variations of the predicted material loss. Finally, the reliability assessment of these systems is performed.

Author(s):  
Mohammad Pourmostafaei ◽  
Mohammad Pourgol-Mohammad ◽  
Mojtaba Yazdani ◽  
Hossein Salimi

In this paper, a new model is proposed for system degradation evaluation under sliding wear failure mechanism. This model estimates the material loss by progression of sliding distance. This model is generated by considering physical and geometrical aspects of system under wear mechanism. Several sets of experimental data are used for validation of the presented model. These experimental data are related to pin-on-disc test of Tungsten Carbide pins. These sets of data include initially conformal and non-conformal contacts. One set of data of pin-on-disc test by ASTM-G99 standard is used for additional validation of the model and for investigation of normal load effects on the parameters of presented model. Finally, uncertainty analysis is done by Monte-Carlo simulation to determine the variations of the predicted wear caused material loss.


Author(s):  
J H Bang ◽  
J H Song ◽  
G H Bae ◽  
N S Park ◽  
S O Choi ◽  
...  

2016 ◽  
Vol 254 ◽  
pp. 231-236 ◽  
Author(s):  
Ion Dragoş Uţu ◽  
Gabriela Marginean ◽  
Iosif Hulka ◽  
Viorel Aurel Şerban

Microstructure and wear properties of the Al2O3-13.wt% TiO2 thermally sprayed coatings before and after remelting were investigated in this study. The coatings were deposited on a pure titanium substrate using the atmospheric plasma spraying (APS) process. The as-sprayed coatings were electron beam (EB) modified in order to improve their compactness and bonding strength.The effect of EB remelting on the microstructure, phase constituents and wear properties was investigated using scanning electron microscopy (SEM), X-Ray diffraction technique and hardness measurements. The sliding wear behavior was tested using a pin on disk method.The results showed that the remelting process had a positive effect removing the lamellar defect of the as-sprayed coating and improving the compactness, hardness and wear behavior.


2013 ◽  
Vol 470 ◽  
pp. 781-784 ◽  
Author(s):  
Chien Yi Huang ◽  
Yueh Hsun Lin ◽  
Eric Huang

A scientific approach is proposed in this research to investigate a disk on module (DOM) product's activation energy based on experimental data that eliminates subjective experience. This study considers multiple temperature conditions to enhance the accuracy of activation energy estimation. In order to ensure the consistency of failure mode in each temperature scenario, the slopes of Weibul probability plots obtained from the failure data are calculated followed by an examination for parallelism. The estimated life time under normal service condition differs from the results obtained using the industrial standard given activation energy by approximately 42%.


2011 ◽  
Vol 339 ◽  
pp. 342-348
Author(s):  
Hai Jun Tang ◽  
Hong Yu Yao

The paper presents a failure analysis on a counterweight assembly installed on crank shaft which resulted in an in-flight shutdown of a piston aeroengine. The counterweight assembly failure includes counterweight block material loss and fractured washer which is the most crucial part for in-flight shutdown in this type of aeroengine. Macro observation, fractography analysis, metallography analysis and hardness test were conducted on the failed counterweight assembly. The result shows that failure mechanism of counterweight block and washer is fatigue. The washer failure is likely due to inappropriate heat treatment process and continuous impact in flight by slightly tilted roller. Counterweight material loss is attributed to stress concentration, low structure strength and impact came from the tilted roller. Finally some safety suggestion on design and maintenance is given.


Author(s):  
Sahar Ghatrehsamani ◽  
Saleh Akbarzadeh

Wear coefficient and friction coefficient are two of the key parameters in the performance of any tribo-system. The main purpose of the present research is to use continuum damage mechanics to predict wear coefficient. Thus, a contact model is utilized that can be used to obtain the friction coefficient between the contacting surfaces. By applying this model to the continuum damage mechanics model, the wear coefficient between dry surfaces is predicted. One of the advantages of using this model is that the wear coefficient can be numerically predicted unlike other methods which highly rely on experimental data. In order to verify the results predicted by this model, tests were performed using pin-on-disk test rig for several ST37 samples. The results indicated that the wear coefficient increases with increasing the friction coefficient.


2021 ◽  
Vol 63 (2) ◽  
pp. 143-150
Author(s):  
Torben Buttler ◽  
Jens Hamje ◽  
Rolf Reiter ◽  
Volker Wesling

Abstract During polymer extrusion there are a variety of situations in which the screwthread of the extrusion screw has an unlubricated metal-to-metal contact with the barrel wall. At the same time the screw coating is subjected to the highest loads. The combination of a secondary hardening cold work steel 1.2379 and a chromium nitride coating deposited by ARC-PVD, which is frequently used in polymer processing, is characterized and investigated. The characterization is done by metallographic examination, SEM and CLSM. The tests were performed on a pin-on-disk and a pin-roll test rig. Different roughness levels were tested on the pin-on-disk test, where massive differences in wear behavior were found. A hybrid surface structure is proposed to optimize the tribosystem. On the pin-on-disk test stand, rollers made of the same material pairing were tested. The test speed was varied to highlight differences and similarities between the tribological systems. A wear minimization of 50 % was achieved and the similarities between the tribological systems were highlighted. In addition, the investigations led to the development of a new model thesis which provides a reason for the development of stippling on the screw when processing polycarbonate.


2007 ◽  
Vol 342-343 ◽  
pp. 557-560
Author(s):  
Kwon Yong Lee ◽  
Hwan Kim ◽  
D.W. Kim ◽  
Dae Joon Kim ◽  
Myung Hyun Lee ◽  
...  

The sliding wear of four different compositions of novel low temperature degradation-free zirconia/alumina (LTD-free Z/A) composites were characterized in a ceramicceramic point contact pair. The wear tests were performed by a pin-on-disk type wear tester in a linear reciprocal sliding motion with a point contact in both dry and bovine serum lubricated conditions at room temperature. For the dry sliding wear tests, AZ-2 (20 vol% (Y,Nb,Ce)-TZP/ 80 vol% Al2O3) showed the best wear resistance among four kinds of LTD-free Z/A composites. For the bovine serum lubricated sliding wear tests, wear was too little to be measured for all kinds of Z/A composites. These novel LTD-free Z/A composites having excellent wear resistance demonstrated a potential as the alternative materials for the ceramic- ceramic contact pairs of femoral head and acetabular liner in total hip replacement.


2012 ◽  
Vol 482-484 ◽  
pp. 1592-1595 ◽  
Author(s):  
Ji Xin Zhang ◽  
Jian Chun Fan ◽  
Yong Jin Xie ◽  
Han Chuan Wu

Erosion phenomenon is quite common in petroleum industry, as one of the main mechanisms of material degradation, occurs frequently on high-pressure pipelines in hydraulic fracturing operation. With the increasing of operation times, the erosion and corrosion defects on the inner surface of the pipeline, would lead to serious material loss and equipment failure. In this paper a new type of test machine was developed to simulate the erosive wear behavior of metal materials caused by the multiphase fluid such as fracturing fluid, and study the erosion failure mechanism by various metal erosion influencing factors including the velocity of multiphase flow, solid particles of fracturing proppant and impact angles, etc. The erosion-wear experiments on 20CrNiMo steels used in high-pressure pipelines is described in detail. Finally, the microcosmic surface testing was also used to analyze the erosion failure mechanism of metal materials for high pressure pipelines.


Sign in / Sign up

Export Citation Format

Share Document