Using Wavelet Analysis to Distinguish Cavitation Acoustic Emissions From Blunt Impact Noise

Author(s):  
Christopher Eckersley ◽  
Joost Op 't Eynde ◽  
Mitchell Abrams ◽  
Cameron R. Bass

Abstract Cavitation has been shown to have implications for head injury, but currently there is no solution for detecting the formation of cavitation through the skull during blunt impact. The goal of this communication is to confirm the wideband acoustic wavelet signature of cavitation collapse, and determine that this signature can be differentiated from the noise of a blunt impact. A controlled, laser induced cavitation study was conducted in an isolated water tank to confirm the wide band acoustic signature of cavitation collapse in the absence of a blunt impact. A clear acrylic surrogate head was impacted to induce blunt impact cavitation. The bubble formation was imaged using a high speed camera, and the collapse was synched up with the wavelet transform of the acoustic emission. Wideband acoustic response is seen in wavelet transform of positive laser induced cavitation tests, but absent in laser induced negative controls. Clear acrylic surrogate tests showed the wideband acoustic wavelet signature of collapse can be differentiated from acoustic noise generated by a blunt impact. Broadband acoustic signal can be used as a biomarker to detect the incidence of cavitation through the skull as it consists of frequencies that are low enough to potentially pass through the skull but high enough to differentiate from blunt impact noise. This lays the foundation for a vital tool to conduct CSF cavitation research in-vivo.

Sensors ◽  
2020 ◽  
Vol 20 (22) ◽  
pp. 6644
Author(s):  
Giacomo Picardi ◽  
Clara Borrelli ◽  
Augusto Sarti ◽  
Giovanni Chimienti ◽  
Marcello Calisti

Underwater robots emit sound during operations which can deteriorate the quality of acoustic data recorded by on-board sensors or disturb marine fauna during in vivo observations. Notwithstanding this, there have only been a few attempts at characterizing the acoustic emissions of underwater robots in the literature, and the datasheets of commercially available devices do not report information on this topic. This work has a twofold goal. First, we identified a setup consisting of a camera directly mounted on the robot structure to acquire the acoustic data and two indicators (i.e., spectral roll-off point and noise introduced to the environment) to provide a simple and intuitive characterization of the acoustic emissions of underwater robots carrying out specific maneuvers in specific environments. Second, we performed the proposed analysis on three underwater robots belonging to the classes of remotely operated vehicles and underwater legged robots. Our results showed how the legged device produced a clearly different signature compared to remotely operated vehicles which can be an advantage in operations that require low acoustic disturbance. Finally, we argue that the proposed indicators, obtained through a standardized procedure, may be a useful addition to datasheets of existing underwater robots.


2020 ◽  
Vol 11 (1) ◽  
Author(s):  
Jiang Lan Fan ◽  
Jose A. Rivera ◽  
Wei Sun ◽  
John Peterson ◽  
Henry Haeberle ◽  
...  

AbstractUnderstanding the structure and function of vasculature in the brain requires us to monitor distributed hemodynamics at high spatial and temporal resolution in three-dimensional (3D) volumes in vivo. Currently, a volumetric vasculature imaging method with sub-capillary spatial resolution and blood flow-resolving speed is lacking. Here, using two-photon laser scanning microscopy (TPLSM) with an axially extended Bessel focus, we capture volumetric hemodynamics in the awake mouse brain at a spatiotemporal resolution sufficient for measuring capillary size and blood flow. With Bessel TPLSM, the fluorescence signal of a vessel becomes proportional to its size, which enables convenient intensity-based analysis of vessel dilation and constriction dynamics in large volumes. We observe entrainment of vasodilation and vasoconstriction with pupil diameter and measure 3D blood flow at 99 volumes/second. Demonstrating high-throughput monitoring of hemodynamics in the awake brain, we expect Bessel TPLSM to make broad impacts on neurovasculature research.


Sensors ◽  
2021 ◽  
Vol 21 (4) ◽  
pp. 1548
Author(s):  
Jiuling Hu ◽  
Lianjin Hong ◽  
Lili Yin ◽  
Yu Lan ◽  
Hao Sun ◽  
...  

At present, high-speed underwater acoustic communication requires underwater transducers with the characteristics of low frequency and broadband. The low-frequency transducers also are expected to be low-frequency directional for realization of point-to-point communication. In order to achieve the above targets, this paper proposes a new type of flextensional transducer which is constructed of double mosaic piezoelectric ceramic rings and spherical cap metal shells. The transducer realizes broadband transmission by means of the coupling between radial vibration of the piezoelectric rings and high-order flexural vibration of the spherical cap metal shells. The low-frequency directional transmission of the transducer is realized by using excitation signals with different amplitude and phase on two mosaic piezoelectric rings. The relationship between transmitting voltage response (TVR), resonance frequency and structural parameters of the transducer is analyzed by finite element software COMSOL. The broadband performance of the transducer is also optimized. On this basis, the low-frequency directivity of the transducer is further analyzed and the ratio of the excitation signals of the two piezoelectric rings is obtained. Finally, a prototype of the broadband ring flextensional underwater transducer is fabricated according to the results of simulation. The electroacoustic performance of the transducer is tested in an anechoic water tank. Experimental results show that the maximum TVR of the transducer is 147.2 dB and the operation bandwidth is 1.5–4 kHz, which means that the transducer has good low-frequency, broadband transmission capability. Meanwhile, cardioid directivity is obtained at 1.4 kHz and low-frequency directivity is realized.


Author(s):  
Xiufeng Li ◽  
Victor T C Tsang ◽  
Lei Kang ◽  
Yan Zhang ◽  
Terence T W Wong

AbstractLaser diodes (LDs) have been considered as cost-effective and compact excitation sources to overcome the requirement of costly and bulky pulsed laser sources that are commonly used in photoacoustic microscopy (PAM). However, the spatial resolution and/or imaging speed of previously reported LD-based PAM systems have not been optimized simultaneously. In this paper, we developed a high-speed and high-resolution LD-based PAM system using a continuous wave LD, operating at a pulsed mode, with a repetition rate of 30 kHz, as an excitation source. A hybrid scanning mechanism that synchronizes a one-dimensional galvanometer mirror and a two-dimensional motorized stage is applied to achieve a fast imaging capability without signal averaging due to the high signal-to-noise ratio. By optimizing the optical system, a high lateral resolution of 4.8 μm has been achieved. In vivo microvasculature imaging of a mouse ear has been demonstrated to show the high performance of our LD-based PAM system.


2021 ◽  
Vol 21 (10) ◽  
pp. 248
Author(s):  
Xin Pei ◽  
Jian Li ◽  
Na Wang ◽  
Toktonur Ergesh ◽  
Xue-Feng Duan ◽  
...  

Abstract A multi-function digital baseband data acquisition system is designed for the sampling, distribution and recording of wide-band multi-channel astronomical signals. The system hires a SNAP2 board as a digital baseband converter to digitize, channelize and packetize the received signal. It can be configured dynamically from a single channel to eight channels with a maximum bandwidth of 4096 MHz. Eight parallel HASHPIPE instances run on four servers, each carrying two NVMe SSD cards, achieving a total continuous write rate of 8 GB s−1. Data are recorded in the standard VDIF file format. The system is deployed on a 25-meter radio telescope to verify its functionality based on pulsar observations. Our results indicate that during the 30-minute observation period, the system achieved zero data loss at a data recording rate of 1 GB s−1 on a single server. The system will serve as a verification platform for testing the functions of the QTT (QiTai radio Telescope) digital backend system. In addition, it can be used as a baseband/VLBI (Very Long Baseline Interferometry) recorder or D-F-engine of correlator/beamformer as well.


Sign in / Sign up

Export Citation Format

Share Document