A Unique Approach for Thermo-Economic Optimization of an Intercooled, Reheat and Recuperated Gas Turbine for Cogeneration Applications

Author(s):  
R. Bhargava ◽  
A. Peretto

In the present paper, a comprehensive methodology for the thermo-economic performance optimization of an intercooled reheat (ICRH) gas turbine with recuperation for cogenerative applications has been presented covering a wide range of power-to-heat ratio values achievable. To show relative changes in the thermo-economic performance for the recuperated ICRH gas turbine cycle, results for ICRH, recuperated Brayton and simple Brayton cycles are also included in the paper. For the three load cases investigated, the recuperated ICRH gas turbine cycle provides the highest values of electric efficiency and Energy Saving Index for the cogenerative systems requiring low thermal loads (high power-to-heat ratio) compared to the other cycles. Also, this study showed, in general, that the recuperated ICRH cycle permits wider power-to-heat ratio range compared to the other cycles and for different load cases examined, a beneficial thermodynamic characteristic for the cogeneration applications. Furthermore, this study clearly shows that implementation of the recuperated ICRH cycle in a cogeneration system will permit to design a gas turbine which has the high specific work capacity and high electric efficiency at low value of the overall cycle pressure ratio compared to the other cycles studied. Economic performance of the investigated gas turbine cycles have been found dependent on the power-to-heat ratio value and the selected cost structure (fuel cost, electric sale price, steam sale price etc.), the results for a selected cost structure in the study are discussed in this paper.

2002 ◽  
Vol 124 (4) ◽  
pp. 881-891 ◽  
Author(s):  
R. Bhargava ◽  
A. Peretto

In the present paper, a comprehensive methodology for the thermoeconomic performance optimization of an intercooled reheat (ICRH) gas turbine with recuperation for cogenerative applications has been presented covering a wide range of power-to-heat ratio values achievable. To show relative changes in the thermoeconomic performance for the recuperated ICRH gas turbine cycle, results for ICRH, recuperated Brayton and simple Brayton cycles are also included in the paper. For the three load cases investigated, the recuperated ICRH gas turbine cycle provides the highest values of electric efficiency and Energy Saving Index for the cogenerative systems requiring low thermal loads (high power-to-heat ratio) compared to the other cycles. Also, this study showed, in general, that the recuperated ICRH cycle permits wider power-to-heat ratio range compared to the other cycles and for different load cases examined, a beneficial thermodynamic characteristic for the cogeneration applications. Furthermore, this study clearly shows that implementation of the recuperated ICRH cycle in a cogeneration system will permit to design a gas turbine which has the high specific work capacity and high electric efficiency at low value of the overall cycle pressure ratio compared to the other cycles studied. Economic performance of the investigated gas turbine cycles have been found dependent on the power-to-heat ratio value and the selected cost structure (fuel cost, electric sale price, steam sale price, etc.), the results for a selected cost structure in the study are discussed in this paper.


Author(s):  
J H Horlock

A graphical method of calculating the performance of gas turbine cycles, developed by Hawthorne and Davis (1), is adapted to determine the pressure ratio of a combined cycle gas turbine (CCGT) plant which will give maximum overall efficiency. The results of this approximate analysis show that the optimum pressure ratio is less than that for maximum efficiency in the higher level (gas turbine) cycle but greater than that for maximum specific work in that cycle. Introduction of reheat into the higher cycle increases the pressure ratio required for maximum overall efficiency.


1970 ◽  
Vol 185 (1) ◽  
pp. 953-961 ◽  
Author(s):  
N Gašparović ◽  
J. G. Hellemans

Water injection into the compressed air between the compressor and the heat exchanger of a gas turbine plant represents only one of various possible methods of introducing water into a gas turbine cycle. With this process, it is advantageous to inject just sufficient water to produce saturation of the compressed air with water vapour. Assuming that the same size of heat exchanger is used, the following changes are introduced as compared with a gas turbine cycle without water injection. The efficiency is increased to an extent equivalent to raising the temperature at the turbine inlet by 100 degC. The gain in specific work is still greater. It attains values which can only be achieved with about 140 degC higher temperature at the turbine inlet. With a normal size of heat exchanger, the water consumption is about 6–8 per cent of the mass flow of air. This rate of consumption is not high enough to introduce any detrimental side effects in the cycle. Special water treatment is not necessary. The performance of existing designs or installations without a heat exchanger can be improved by adding a heat exchanger and water injection without necessitating any change in pressure ratio.


Author(s):  
Mortaza Yari

The evaporative gas turbine cycle is a new high-efficiency power cycle that has reached the pilot plant testing stage. The latest configuration proposed for this cycle is known as part flow evaporative gas turbine cycle (PEvGT) in which humidification is combined with steam injection. Having advantages of both steam injected and humid air cycles, it is regarded as a very desirable plant for future. The aim of this work is to investigate the economic performance of the PEvGT cycles: PEvGT and PEvGT-IC (Intercooled PEvGT cycle), based on the thermoeconomic analysis. The results are presented and the influence of the several parameters is discussed: pressure ratio, part-flow humidification rate and the cycle configuration. Also the thermoeconomic optimization of the cycles have been done and discussed.


Author(s):  
M. Yari ◽  
K. Sarabchi

Various advanced gas turbine cycles have been proposed to compete with combined cycles. One of the promising cycles is humid air turbine cycle. The latest configuration proposed for this cycle is known as part flow evaporative gas turbine cycle (PEvGT) in which humidification is combined with steam injection. Having advantages of both steam injected and humid air cycles, it is regarded as a very desirable plant for future. The objectives of this paper are: Development of a comprehensive model for analysis of PEvGT cycle in order to predict its performance parameters depending on different design conditions. It should be noted that the model validated with available data in literature. Comparing the performance of PEvGT cycle with full flow evaporative gas turbine cycle (FEvGT) and stand alone steam injected gas turbine cycle (STIG). Based on a computer code developed for this research, a parametric analysis was carried out for the above-mentioned cycles for a wide range of pressure ratio and turbine inlet temperature variations. The obtained results show that the specific net work of PEvGT cycle, for given conditions, is higher than for both FEvGT and STIG cycles. On the other hand, the efficiency of PEvGT is higher than STIG but is slightly lower than FEvGT cycle.


1978 ◽  
Vol 100 (4) ◽  
pp. 640-646 ◽  
Author(s):  
P. Donovan ◽  
T. Cackette

A set of factors which reduces the variability due to ambient conditions of the hydrocarbon, carbon monoxide, and oxides of nitrogen emission indices has been developed. These factors can be used to correct an emission index to reference day ambient conditions. The correction factors, which vary with engine rated pressure ratio for NOx and idle pressure ratio for HC and CO, can be applied to a wide range of current technology gas turbine engines. The factors are a function of only the combustor inlet temperature and ambient humidity.


2015 ◽  
Vol 5 (2) ◽  
pp. 89
Author(s):  
Munzer S. Y. Ebaid ◽  
Qusai Z. Al-hamdan

<p class="1Body">Several modifications have been made to the simple gas turbine cycle in order to increase its thermal efficiency but within the thermal and mechanical stress constrain, the efficiency still ranges between 38 and 42%. The concept of using combined cycle power or CPP plant would be more attractive in hot countries than the combined heat and power or CHP plant. The current work deals with the performance of different configurations of the gas turbine engine operating as a part of the combined cycle power plant. The results showed that the maximum CPP cycle efficiency would be at a point for which the gas turbine cycle would have neither its maximum efficiency nor its maximum specific work output. It has been shown that supplementary heating or gas turbine reheating would decrease the CPP cycle efficiency; hence, it could only be justified at low gas turbine inlet temperatures. Also it has been shown that although gas turbine intercooling would enhance the performance of the gas turbine cycle, it would have only a slight effect on the CPP cycle performance.</p>


Author(s):  
Esa Utriainen ◽  
Bengt Sundén

The application of recuperators in advanced thermodynamic cycles is growing due to stronger demands of low emissions of pollutants and the necessity of improving the cycle efficiency of power plants to reduce the fuel consumption. This paper covers applications and types of heat exchangers used in gas turbine units. The trends of research and development are brought up and the future need for research and development is discussed. Material aspects are covered to some extent. Attempts to achieve compact heat exchangers for these applications are also discussed. With the increasing pressure ratio in the gas turbine cycle, large pressure differences between the hot and cold sides exist. This has to be accounted for. The applicability of CFD (Computational Fluid Dynamics) is discussed and a CFD–approach is presented for a specific recuperator. This recuperator has narrow wavy ducts with complex cross-sections and the hydraulic diameter is so small that laminar flow prevails. The thermal-hydraulic performance is of major concern.


Author(s):  
Ivan G. Rice

Interest in the reheat-gas turbine (RHGT) as a way to improve combined-cycle efficiency is gaining momentum. Compression intercooling makes it possible to readily increase the reheat-gas-turbine cycle-pressure ratio and at the same time increase gas-turbine output; but at the expense of some combined-cycle efficiency and mechanical complexity. This paper presents a thermodynamic analysis of the intercooled cycle and pinpoints the proper intercooling pressure range for minimum combined-cycle-efficiency loss. At the end of the paper two-intercooled reheat-gas-turbine configurations are presented.


Author(s):  
K. K. Botros ◽  
G. R. Price ◽  
R. Parker

Hybrid PSOFC/GT cycles consisting of pressurized solid oxide fuel cells integrated into gas turbine cycles are emerging as a major new power generation concept. These hybrid cycles can potentially offer thermal efficiencies exceeding 70% along with significant reductions in greenhouse gas and NOX emissions. This paper considers the PSOFC/GT cycle in terms of electrical and mechanical power generation with particular focus on gas pipeline companies interested in diversifying their assets into distributed electric generation or lowering pollutant emissions while more efficiently transporting natural gas. By replacing the conventional GT combustion chamber with an internally reformed PSOFC, electrical power is generated as a by-product while hot gases exiting the fuel cell are diverted into the gas turbine for mechanical power. A simple one-dimensional thermodynamic model of a generic PSOFC/GT cycle has shown that overall thermal efficiencies of 65% are attainable, whilst almost tripling the specific work (i.e. energy per unit mass of air). The main finding of this paper is that the amount of electric power generated ranges from 60–80% of the total power available depending on factors such as the system pressure ratio and degree of supplementary firing before the gas turbine. Ultimately, the best cycle should be based on the “balance of plant”, which considers factors such as life cycle cost analysis, business and market focus, and environmental emission issues.


Sign in / Sign up

Export Citation Format

Share Document