Numerical and Experimental Investigation on the Radial Force Characteristic of a Large Double Suction Centrifugal Pump in a Real Pumping Station

Author(s):  
Zhifeng Yao ◽  
Fujun Wang ◽  
Zichao Zhang ◽  
Ruofu Xiao ◽  
Chenglian He

The pump operation stability is one of the most important indicators for large discharge pumping stations. Impeller seal rings wear is a key problematic issue. A large double suction centrifugal pump in a real water supply pumping station is numerically and experimentally investigated, of which the seal rings are seriously wore on a fixed location. The pump shaft throws in two orthorhombic directions are measured at flow rates ranging from 0 to 110% of nominal flow rate, as well as the startup and shut down periods. And careful analysis of radial forces under various steady and unsteady conditions is carried out combining with the experimental results. The results show that the value of the shaft displacement obviously increases as the flow rate decreases, especially on the operating conditions with the flow rates below 87% of the design flow rate for the drive end side. The absolute value of the shaft displacement is 0.37mm, which is more than 3 times as large as that at nominal operating condition. There exit a lasting time of large shaft displacements during pump startup and shutdown periods, and the largest value of shaft displacement at the drive end side happens during the pump startup process, which can be increase to 0.95mm. There exists relative large radial force, and the direction of which is exactly the same with the pump shaft displacement at the flow rate from 0.73Qn to 0.32Qn, and also meet the wear locations of the impeller seal rings.

Author(s):  
Can Kang ◽  
Ning Mao ◽  
Chen Pan ◽  
Yang Zhu ◽  
Bing Li

A low-specific-speed centrifugal pump equipped with long and short blades is studied. Emphasis is placed on the pump performance and inner flow characteristics at low flow rates. Each short blade is intentionally shifted towards the back surface of the neighboring long blade, and the outlet parts of the short blades are uniformly shortened. Unsteady numerical simulation is conducted to disclose inner flow patterns associated with the modified design. Thereby, a comparison is enabled between the two schemes featured by different short blades. Both practical operation data and numerical results support that the deviation and cutting of the short blades can eliminate the positive slope of pump head curve at low flow rates. Therefore, the modification of short blades improves the pump operation stability. Due to the shortening of the outlet parts of the short blades, velocity distributions between impeller outlet and radial diffuser inlet exhibit explicitly altered circumferential flow periodicity. Pressure fluctuations in the radial diffuser are complex in terms of diversified periodicity and amplitudes. Flow rate influences pressure fluctuations in the radial diffuser considerably. As flow rate decreases, the regularity of the orbit of hydraulic loads exerted upon the impeller collapses while hydraulic loads exerted upon the short blades remain circumferentially periodic.


2020 ◽  
Vol 34 (26) ◽  
pp. 2050286
Author(s):  
Fen Lai ◽  
Xiangyuan Zhu ◽  
Yongqiang Duan ◽  
Guojun Li

The performance and service life of centrifugal pumps can be influenced by the clocking effect. In this study, 3D numerical calculations based on the k-omega shear stress transport model are conducted to investigate the clocking effect in a centrifugal pump. Time-averaged behavior and transient behavior are analyzed. Results show that the optimum diffuser installation angle in the centrifugal pump is [Formula: see text] due to the minimum total pressure loss and radial force acting on the impeller. Total pressure loss, particularly in the volute, is considerably influenced by the clocking effect. The difference in total pressure loss in the volute at different clocking positions is 2.75 m under the design flow rate. The large total pressure loss in the volute is primarily caused by the large total pressure gradient within the vicinity of the volute tongue. The radial force acting on the impeller is also considerably affected by the clocking effect. When the diffuser installation angle is [Formula: see text], flow rate fluctuations in the volute and impeller passage are minimal, and flow rate distribution in the diffuser passage is more uniform than those in other diffuser installation angles. Moreover, static pressure fluctuations in the impeller midsection and the diffuser inlet section are at the minimum value. These phenomena explain the minimum radial force acting on the impeller. The findings of this study can provide a useful reference for the design of centrifugal pumps.


1991 ◽  
Author(s):  
Ronald D. Flack ◽  
Steven M. Miner ◽  
Ronald J. Beaudoin

Turbulence profiles were measured in a centrifugal pump with an impeller with backswept blades using a two directional laser velocimeter. Data presented includes radial, tangential, and cross product Reynolds stresses. Blade to blade profiles were measured at four circumferential positions and four radii within and one radius outside the four bladed impeller. The pump was tested in two configurations; with the impeller running centered within the volute, and with the impeller orbiting with a synchronous motion (ε/r2 = 0.016). Flow rates ranged from 40% to 106% of the design flow rate. Variation in profiles among the individual passages in the orbiting impeller were found. For several regions the turbulence was isotropic so that the cross product Reynolds stress was low. At low flow rates the highest cross product Reynolds stress was near the exit. At near design conditions the lowest cross product stress was near the exit, where uniform flow was also observed. Also, near the exit of the impeller the highest turbulence levels were seen near the tongue. For the design flow rate, inlet turbulence intensities were typically 9% and exit turbulence intensities were 6%. For 40% flow capacity the values increased to 18% and 19%, respectively. Large local turbulence intensities correlated with separated regions. The synchronous orbit did not increase the random turbulence, but did affect the turbulence in the individual channels in a systematic pattern.


2019 ◽  
Vol 11 (3) ◽  
pp. 168781401982590 ◽  
Author(s):  
Kai Wang ◽  
Yu-cheng Jing ◽  
Xiang-hui He ◽  
Hou-lin Liu

In order to enhance the efficiency of centrifugal pump, the structure of a centrifugal pump with vaned diffuser, whose specific speed is 190, was numerically improved by trimming back-blades of impeller and smoothing sharp corner in annular chamber. The energy performance, the internal flow field, the axial force, the radial force, and the pressure pulsation of the pump were analyzed. Results show that efficiency of the improving scheme 1 under the design flow rate is 77.47%, which can balance 69.82% of the axial force, while efficiency of the improving scheme 2 under the design flow rate is the maximum, which could still balance 62.74% of the axial force. The pressure pulsations of the improving scheme 2 at the typical monitoring points are less than that of the improving scheme 1 and the original scheme. The difference of the radial force peak between the improving scheme 1 and the improving scheme 2 is very small. The vector distributions of the radial force of the improving scheme 1 and the improving scheme 2 are more uniform than that of the original scheme. Considering the efficiency, pressure pulsation, and axial force, experiment measurements on the improving scheme 2 were carried out to verify the effectiveness of the improvement result. Results of energy performance experiment show that efficiency of the improving scheme 2 under the design flow rate is 76.48%, which is 5.26 percentage points higher than that of the original scheme.


1992 ◽  
Vol 114 (2) ◽  
pp. 350-358 ◽  
Author(s):  
R. D. Flack ◽  
S. M. Miner ◽  
R. J. Beaudoin

Turbulence profiles were measured in a centrifugal pump with an impeller with backswept blades using a two-directional laser velocimeter. Data presented include radial, tangential, and cross product Reynolds stresses. Blade-to-blade profiles were measured at four circumferential positions and four radii within and one radius outside the four-bladed impeller. The pump was tested in two configurations: with the impeller running centered within the volute, and with the impeller orbiting with a synchronous motion (ε/r2 = 0.016). Flow rates ranged from 40 to 106 percent of the design flow rate. Variation in profiles among the individual passages in the oribiting impeller were found. For several regions the turbulence was isotropic so that the cross product Reynolds stress was low. At low flow rates the highest cross product Reynolds stress was near the exit. At near-design conditions the lowest cross product stress was near the exit, where uniform flow was also observed. Also, near the exit of the impeller the highest turbulence levels were seen near the tongue. For the design flow rate, inlet turbulence intensities were typically 9 percent and exit turbulence intensities were 6 percent. For 40 percent flow capacity the values increased to 18 and 19 percent, respectively. Large local turbulence intensities correlated with separated regions. The synchronous orbit did not increase the random turbulence, but did affect the turbulence in the individual channels in a systematic pattern.


Author(s):  
Yasuyuki Nishi ◽  
Junichiro Fukutomi ◽  
Ryota Fujiwara

A single-blade centrifugal pump is widely used as a sewage pump. However, a single-blade is acted on by a large radial thrust during the pump operation because of the geometrical axial asymmetry of the impeller. Therefore to secure the pump reliability, it is necessary to grasp the radial thrust quantitatively and elucidate a behavior and a generation mechanism. This study investigated the radial thrust acting on a single-blade centrifugal impeller by an experiment and a CFD analysis, and the results clearly indicated the following facts. The fluctuating component of the radial thrust increased as the flow rate changed from the design flow rate to a partial or excessive flow rate. Furthermore, the radial thrust was modeled by a combination of three components, inertia, momentum and pressure components by applying unsteady conservation of momentum to this impeller. The grand total of these components was in agreement with the radial thrust calculated by integrating the pressure and the shearing stress on the impeller surface. In addition the behavior of each component was shown and the effects of those components that gave to the radial thrust were clarified. The pressure component had the greatest effect on a time-averaged value and a fluctuating component of the radial thrust. The time-averaged value of the inertia component was approximately 0 even if the flow rate changed. But its fluctuating component had a magnitude nearly comparable to the pressure component at a partial flow rate and slightly decreased with increase of the flow rate.


2012 ◽  
Vol 152-154 ◽  
pp. 935-939 ◽  
Author(s):  
Qiang Fu ◽  
Shou Qi Yuan ◽  
Rong Sheng Zhu

In order to study the rules of pressure fluctuation and the radial force under different positions in a centrifugal pump with low specific speed, and to find the relationship between each other, the three-dimensional ,unsteady Reynolds-averaged Navier-stokes equations with shear stress transport turbulent models were solved. The pressure fluctuation was obtained. The results showed that the pressure fluctuations were visible. The pressure fluctuations in the volute were relatively low at the design flow rate condition. The blade passing frequency dominates the pressure fluctuations, high frequency contents were found on the outlet of impeller but no high frequency information occured in casing. The radial force on the impeller was unsteady especially at the small flow rate.


Author(s):  
Francois G. Louw ◽  
Theodor W. von Backström ◽  
Sybrand J. van der Spuy

Large axial flow fans are used in forced draft air cooled heat exchangers (ACHEs). Previous studies have shown that adverse operating conditions cause certain sectors of the fan, or the fan as a whole to operate at very low flow rates, thereby reducing the cooling effectiveness of the ACHE. The present study is directed towards the experimental and numerical analyses of the flow in the vicinity of an axial flow fan during low flow rates. This is done to obtain the global flow structure up and downstream of the fan. A near-free-vortex fan, designed for specific application in ACHEs, is used for the investigation. Experimental fan testing was conducted in a British Standard 848, type A fan test facility, to obtain the fan characteristic. Both steady-state and time-dependent numerical simulations were performed, depending on the operating condition of the fan, using the Realizable k-ε turbulence model. Good agreement is found between the numerically and experimentally obtained fan characteristic data. Using data from the numerical simulations, the time and circumferentially averaged flow field is presented. At the design flow rate the downstream fan jet mainly moves in the axial and tangential direction, as expected for a free-vortex design criteria, with a small amount of radial flow that can be observed. As the flow rate through the fan is decreased, it is evident that the down-stream fan jet gradually shifts more diagonally outwards, and the region where reverse flow occur between the fan jet and the fan rotational axis increases. At very low flow rates the flow close to the tip reverses through the fan, producing a small recirculation zone as well as swirl at certain locations upstream of the fan.


2015 ◽  
Vol 137 (6) ◽  
Author(s):  
Qiaorui Si ◽  
Patrick Dupont ◽  
Annie-Claude Bayeul-Lainé ◽  
Antoine Dazin ◽  
Olivier Roussette ◽  
...  

Measurements are processed on a centrifugal pump model, which works with air and performs with the vane-island type diffuser of a real hydraulic pump, under five flow rates to investigate the internal flow characteristics and their influence on overall pump performance. The mean flow characteristics inside the diffuser are determined by using a miniature three-hole probe connected to an online data acquisition system. The flow structure at the inlet section of the diffuser is analyzed in detail, with a focus on the local pressure loss inside the vaneless gap and incidence angle distributions along the hub-to-shroud direction of the diffuser. Some existing calculations, including leakage effects, are used to evaluate the pressure recovery downstream of the impeller. Furthermore, particle image velocimetry (PIV) measurement results are obtained to help analyze the flow characteristics inside the vane-island diffuser. Each PIV measuring plane is related to one particular diffuser blade-to-blade channel and is analyzed by using the time-averaged method according to seven different relative positions of the impeller. Measurement results show that main loss is produced inside the vaneless part of the diffuser at low flow rates, which might have been caused by the strong rotor–stator interaction. When the impeller flow rate is greater than the diffuser design flow rate, a large fluctuating separated region occurs after the throat of the diffuser on the pressure side. Mean loss originates from the unsteady pressure downstream of the diffuser throat. For better characterization of the separations observed in previous experimental studies, complementary unsteady static pressure measurement campaigns have been conducted on the diffuser blade wall. The unsteadiness revealed by these measurements, as well as theirs effects on the diffuser performance, was then studied.


2011 ◽  
Vol 133 (10) ◽  
Author(s):  
Zhifeng Yao ◽  
Fujun Wang ◽  
Lixia Qu ◽  
Ruofu Xiao ◽  
Chenglian He ◽  
...  

Pressure fluctuation is the primary reason for unstable operations of double-suction centrifugal pumps. By using flush mounted pressure transducers in the semispiral suction chamber and the volute casing of a double-suction pump, the pressure fluctuation signals were obtained and recorded at various operating conditions. Spectral analyses were performed on the pressure fluctuation signals in both frequency domain and time-frequency domain based on fast Fourier transform (FFT) and an adaptive optimal-kernel time-frequency representation (AOK TFR). The results show that pressure fluctuations at the impeller rotating frequency and some lower frequencies dominated in the semispiral suction chamber. Pressure fluctuations at the blade passing frequency, the impeller rotating frequency, and their harmonic frequencies were identified in the volute casing. The amplitude of pressure fluctuation at the blade passing frequency significantly increased when the flow rate deviated from the design flow rate. At 107% of the design flow rate, the amplitude increased more than 254% than that at the design flow rate. The time-frequency characteristics of these pressure fluctuations were affected greatly by both operating conditions and measurement locations. At partial flow rates the pulsation had a great irregularity and the amplitudes at the investigated frequencies were much larger than ones at the design flow rate. An asymmetrical pressure fluctuation structure in the volute casing was observed at all flow rates. The pulsation behavior at the blade passing frequency was the most prominent near the volute tongue zone, and the pressure waves propagated in both the radial and circumferential directions.


Sign in / Sign up

Export Citation Format

Share Document