Implication of Different Fuel Injector Configurations for Hydrogen Fuelled Micromix Combustors

Author(s):  
Bhupendra Khandelwal ◽  
Yingchun Li ◽  
Priyadarshini Murthy ◽  
Vishal Sethi ◽  
Riti Singh

A design of a hydrogen fuelled micromix concept based combustor is proposed in this paper. The proposed micromix concept based combustor yields improved mixing, which leads to wider flammability range of the hydrogen-air flames compared to conventional kerosene and micromix concept based combustors. This improved mixing allows the combustion zone to operate at a much lower equivalence ratio than the conventional kerosene based and micromix concept based combustors considered in this study. Furthermore, when burning hydrogen the thermal energy radiated to the surroundings is lower (as the result of using lower equivalence ratio) than that of kerosene, consequently resulting in an increased liner life and lower cooling requirement. The aim of this paper is to highlight the impact of using hydrogen as a fuel in gas turbine combustors. It is perceived that this new micromix concept based combustor would also help in achieving low emissions and better performance. Possibilities for lowering NOx emissions when using hydrogen as a fuel in new designs of micromix combustor are also discussed.

Author(s):  
Donald M. Newburry ◽  
Arthur M. Mellor

The semi–empirical characteristic time model (CTM) has been used previously to correlate and predict emissions data from conventional diffusion flame, gas turbine combustors. The form of the model equation was derived for NOx emissions from laboratory flameholders and then extended to conventional gas turbine combustors. The model relates emissions to the characteristic times of distinct combustion subprocesses, with empirically determined model constants. In this paper, a new model is developed for lean premixed (LP) NOx emissions from a perforated plate flameholder combustor burning propane fuel. Several modifications to the diffusion flame CTM were required, including a new activation energy and a more complicated dependence on combustor pressure. Appropriate model constants were determined from the data, and the correlation results are reasonable. An attempt was made to validate the new model with LP NOx data for a different but geometrically similar flameholder operating at lower pressures. The predictions are good for the low equivalence ratio data. However, a systematic error in the reported equivalence ratios may be adversely affecting the predictions of the higher equivalence ratio data through the calculated adiabatic flame temperature.


Author(s):  
D. A. Sullivan ◽  
P. A. Mas

The effect of inlet temperature, pressure, air flowrate and fuel-to-air ratio on NOx emissions from gas turbine combustors has received considerable attention in recent years. A number of semi-empirical and empirical correlations relating these variables to NOx emissions have appeared in the literature. They differ both in fundamental assumptions and in their predictions. In the present work, these simple NOx correlations are compared to each other and to experimental data. A review of existing experimental data shows that an adequate data base does not exist to evaluate properly the various NOx correlations. Recommendations are proposed to resolve this problem in the future.


1980 ◽  
Author(s):  
T. M. Liu ◽  
R. M. Washam

During the development of a rich-lean staged dry low NOx combustor, the conventional trend of increasing smoke with increasing operating equivalence ratio was found when tests were run with distillate fuel (%H = 13.0). However, when tests were run with residual fuel (%H = 11.4), the trend was reversed. In addition, when the same combustor was run with blends of distillate fuel and residual fuel, a drastic improvement of smoke was observed when only 6 percent of residual fuel was mixed with distillate fuel, and for any blending of more than 10 percent of residual fuel the combustor was practically smoke free. A chemical analysis of fuel samples revealed an appreciable amount of trace metals in the residual fuel, giving rise to the suspicion that the smoke reduction may have been due in part to these trace metals. Of these elements found, vanadium is believed to be the most likely to cause smoke reduction because of its relatively high concentration.


Author(s):  
Richard L. Hack ◽  
Vincent G. McDonell

The impact of fuel composition on the performance of power generation devices is gaining interest as the desire to diversify fuel supplies increases. In the present study, measurements of combustion performance were conducted on a commercial natural gas-fired 60kW gas turbine as a function of fuel composition. A statistically designed experiment was carried out and exhaust emissions were obtained for significant amounts of ethane and propane. In addition, a limited study of the effect of inerts was conducted. The results show that emissions of NOx, CO, and NOx∕NO are not well correlated with common descriptions of the fuel, such as higher heating value or methane number. The results and trends indicate that the presence of higher hydrocarbons in the fuel leads to appreciably higher NOx emissions for both test devices operating under similar lean conditions, while having less impact on CO emissions.


Author(s):  
K. O. Smith ◽  
A. Fahme

Three subscale, cylindrical combustors were rig tested on natural gas at typical industrial gas turbine operating conditions. The intent of the testing was to determine the effect of combustor liner cooling on NOx and CO emissions. In order of decreasing liner cooling, a metal louvre-cooled combustor, a metal effusion-cooled combustor, and a backside-cooled ceramic (CFCC) combustor were evaluated. The three combustors were tested using the same lean-premixed fuel injector. Testing showed that reduced liner cooling produced lower CO emissions as reaction quenching near the liner wall was reduced. A reduction in CO emissions allows a reoptimization of the combustor air flow distribution to yield lower NOx emissions.


Author(s):  
Ahmed E. E. Khalil ◽  
Ashwani K. Gupta

Colorless Distributed Combustion (also referred to as CDC) has been shown to provide ultra-low emissions and enhanced performance of high intensity gas turbine combustors. To achieve distributed combustion, the flowfield needs to be tailored for adequate mixing between reactants and hot reactive species from within the combustor to result in high temperature low oxygen concentration environment prior to ignition. Such reaction distribution results in uniform thermal field and also eliminates any hot spots for mitigating NOx emission. Though CDC have been extensively studied using a variety of geometries, heat release intensities, and fuels, the role of internally recirculated hot reactive gases needs to be further investigated and quantified. In this paper, the impact of internal entrainment of reactive gases on flame structure and behavior is investigated with focus on fostering distributed combustion and providing guidelines for designing future gas turbine combustors operating in distributed combustion mode. To simulate the recirculated gases from within the combustor, a mixture of nitrogen and carbon dioxide is introduced to the air stream prior to mixing with fuel and subsequent combustion. Increase in the amounts of nitrogen and carbon dioxide (simulating increased entrainment), led to volume distributed reaction over a larger volume in the combustor with enhanced and uniform distribution of the OH* chemiluminescence intensity. At the same time, the bluish flame stabilized by the swirler is replaced with a more uniform almost invisible bluish flame. The increased recirculation also reflected on the pollutants emission, where NO emissions were significantly decreased for the same amount of fuel burned. Lowering oxygen concentration from 21% to 15% (due to increased recirculation) resulted in 80∼90% reduction in NO with no impact on CO emission with sub PPM NO emission achieved at an equivalence ratio of 0.7. Flame stabilization at excess recirculation can be achieved using preheated nitrogen and carbon dioxide, achieving true distributed conditions with oxygen concentration below 13%.


Author(s):  
Matteo Cerutti ◽  
Roberto Modi ◽  
Danielle Kalitan ◽  
Kapil K. Singh

As government regulations become increasingly strict with regards to combustion pollutant emissions, new gas turbine combustor designs must produce lower NOx while also maintaining acceptable combustor operability. The design and implementation of an efficient fuel/air premixer is paramount to achieving low emissions. Options for improving the design of a natural gas fired heavy-duty gas turbine partially premixed fuel nozzle have been considered in the current study. In particular, the study focused on fuel injection and pilot/main interaction at high pressure and high inlet temperature. NOx emissions results have been reported and analyzed for a baseline nozzle first. Available experience is shared in this paper in the form of a NOx correlative model, giving evidence of the consistency of current results with past campaigns. Subsequently, new fuel nozzle premixer designs have been investigated and compared, mainly in terms of NOx emissions performance. The operating range of investigation has been preliminarily checked by means of a flame stability assessment. Adequate margin to lean blow out and thermo-acoustic instabilities onset has been found while also maintaining acceptable CO emissions. NOx emission data were collected over a variety of fuel/air ratios and pilot/main splits for all the fuel nozzle configurations. Results clearly indicated the most effective design option in reducing NOx. In addition, the impact of each design modification has been quantified and the baseline correlative NOx emissions model calibrated to describe the new fuel nozzles behavior. Effect of inlet air pressure has been evaluated and included in the models, allowing the extensive use of less costly reduced pressure test campaigns hereafter. Although the observed effect of combustor pressure drop on NOx is not dominant for this particular fuel nozzle, sensitivity has been performed to consolidate gathered experience and to make the model able to evaluate even small design changes affecting pressure drop.


1993 ◽  
Vol 115 (3) ◽  
pp. 554-562 ◽  
Author(s):  
L. H. Cowell ◽  
K. O. Smith

Development of a lean-premixed, liquid-fueled combustor is in progress to achieve ultra-low NOx emissions at typical gas turbine operating conditions. A filming fuel injector design was tested on a bench scale can combustor to evaluate critical design and operating parameters for low-emissions performance. Testing was completed using No. 2 diesel. Key design variables tested include premixing length, swirler angle, injector centerbody diameter, and reduced liner cooling. NOx emissions below 12 ppmv at 9 bar pressure were measured. Corresponding CO levels were 50 ppmv. An optimized injector design was fabricated for testing in a three injector sector of an annular combustor. Operating parameters and test results are discussed in the paper.


1982 ◽  
Vol 104 (1) ◽  
pp. 52-57 ◽  
Author(s):  
S. J. Anderson ◽  
M. A. Friedman ◽  
W. V. Krill ◽  
J. P. Kesselring

Catalytically supported thermal combustion can provide low NOx emissions with gaseous and distillate fuels while maintaining high combustion efficiency. For stationary gas turbines, catalytic combustion may be the only emerging technology that can cost effectively meet recent federal regulations for NOx emissions. Under EPA sponsorship, a small-scale, catalytic gas turbine combustor was developed to evaluate transient and steady state combustor performance. The combustor consisted of a multiple air-atomizing fuel injector, an opposed jet igniter, and a graded-cell monolithic reactor. System startup, including opposed jet ignition and catalyst stabilization, was achieved in 250 seconds. This time interval is comparable to conventional gas turbines. Steady state operation was performed at 0.505 MPa (5 atmospheres) pressure and 15.3 m/s (50 ft/s) reference velocities. Thermal NOx emissions were measured below 10 ppmv, while fuel NOx conversion ranged from 75 to 95 percent. At catalyst bed temperatures greater than 1422K (2100°F), total CO and UHC emissions were less than 50 ppmv indicating combustion efficiency greater than 99.9 percent. Compared with conventional gas turbine combustors, the catalytic reactor operates only within a relatively narrow range of fuel/air ratios. As a result, modified combustor air distribution or fuel staging will be required to achieve the wide turndown required in large stationary systems.