APR+ Core Flow and Pressure Distributions Under the 4 Pump Unbalanced Flow Condition

Author(s):  
K. Kim ◽  
D. J. Euh ◽  
Y. J. Youn ◽  
I. C. Chu ◽  
H. S. Choi ◽  
...  

The core inlet flow rates and exit pressure distributions of an APR+ (Advanced Power Reactor Plus) reactor were evaluated experimentally in this study. The tests were performed in the ACOP (APR+ Core Flow & Pressure) test facility constructed with a linear reduced scale of 1/5 referring to the prototype plant. The major flow path inside the reactor vessel was designed with a preservation of a geometrically similar flow without hindering the dynamic similarity. The 257 core simulators with 771 pressure impulse lines were installed in the ACOP facility to measure the hydraulic characteristics at the inlet and outlet of the fuel assemblies. The pressure distributions along the major flow path were obtained by measuring the static pressure and differential pressures at 584 points. The hydraulic characteristics of the reactor flow under an unbalanced cold leg flow condition were investigated by using an ensemble averaging process of 5 independent tests. The details of these experiments and a data analysis were described in this paper.

Author(s):  
Robin R. Jones ◽  
Oliver J. Pountney ◽  
Bjorn L. Cleton ◽  
Liam E. Wood ◽  
B. Deneys J. Schreiner ◽  
...  

Abstract In modern gas turbines, endwall contouring (EWC) is employed to modify the static pressure field downstream of the vanes and minimise the growth of secondary flow structures developed in the blade passage. Purge flow (or egress) from the upstream rim-seal interferes with the mainstream flow, adding to the loss generated in the rotor. Despite this, EWC is typically designed without consideration of mainstream-egress interactions. The performance gains offered by EWC can be reduced, or in the limit eliminated, when purge air is considered. In addition, EWC can result in a reduction in sealing effectiveness across the rim seal. Consequently, industry is pursuing a combined design approach that encompasses the rim-seal, seal-clearance profile and EWC on the rotor endwall. This paper presents the design of, and preliminary results from a new single-stage axial turbine facility developed to investigate the fundamental fluid dynamics of egress-mainstream flow interactions. To the authors’ knowledge this is the only test facility in the world capable of investigating the interaction effects between cavity flows, rim seals and EWC. The design of optical measurement capabilities for future studies, employing volumetric velocimetry and planar laser induced fluorescence are also presented. The fluid-dynamically scaled rig operates at benign pressures and temperatures suited to these techniques and is modular. The facility enables expedient interchange of EWC (integrated into the rotor bling), blade-fillet and rim-seals geometries. The measurements presented in this paper include: gas concentration effectiveness and swirl measurements on the stator wall and in the wheel-space core; pressure distributions around the nozzle guide vanes at three different spanwise locations; pitchwise static pressure distributions downstream of the nozzle guide vane at four axial locations on the stator platform.


1980 ◽  
Vol 22 (6) ◽  
pp. 305-313 ◽  
Author(s):  
D. S. Kumar ◽  
K. L. Kumar

Annular diffusers are likely to operate with varying amounts of swirl at the inlet. The work described in this paper is concerned mainly with an experimental investigation of subsonic turbulent swirling flows through annular diffusers having diverging hub and casing boundaries. The test facility was designed SO as to peImit different levels of inlet swirl. The static pressure distributions and the axial and tangential velocity profiles were measured with the help of a three-hole cobra probe suitably mounted at different cross sections along the diffuser length. The diffuser performance parameters such as static-pressure recovery, effectiveness, and the total pressure loss coefficient were then computed from the experimental observations. The behaviour of these parameters has been discussed to establish the effect of swirl. The presence of inlet swirl was found to increase the overall static-pressure recovery. A substantial increase in the pressure recovery occurred over the initial stages of diffusion and the gain was maintained thereafter. Improvement in effectiveness was more significant for otherwise stalled diffusers. Introduction of swirl was found to substantially reduce the chances of separation at the casing and to shift the stall from the casing to the hub for the stalled diffusers.


2019 ◽  
Vol 141 (12) ◽  
Author(s):  
Robin R. Jones ◽  
Oliver J. Pountney ◽  
Bjorn L. Cleton ◽  
Liam E. Wood ◽  
B. Deneys J. Schreiner ◽  
...  

Abstract In modern gas turbines, endwall contouring (EWC) is employed to modify the static pressure field downstream of the vanes and minimize the growth of secondary flow structures developed in the blade passage. Purge flow (or egress) from the upstream rim-seal interferes with the mainstream flow, adding to the loss generated in the rotor. Despite this, EWC is typically designed without consideration of mainstream–egress interactions. The performance gains offered by EWC can be reduced, or in the limit eliminated, when purge air is considered. In addition, EWC can result in a reduction in sealing effectiveness across the rim seal. Consequently, industry is pursuing a combined design approach that encompasses the rim-seal, seal-clearance profile, and EWC on the rotor endwall. This paper presents the design of and preliminary results from a new single-stage axial turbine facility developed to investigate the fundamental fluid dynamics of egress–mainstream flow interactions. To the authors' knowledge, this is the only test facility in the world capable of investigating the interaction effects between cavity flows, rim seals, and EWC. The design of optical measurement capabilities for future studies, employing volumetric velocimetry (VV) and planar laser-induced fluorescence (PLIF), is also presented. The fluid-dynamically scaled rig operates at benign pressures and temperatures suited to these techniques and is modular. The facility enables expedient interchange of EWC (integrated into the rotor bling), blade-fillet and rim-seal geometries. The measurements presented in this paper include: gas concentration effectiveness and swirl measurements on the stator wall and in the wheel-space core; pressure distributions around the nozzle guide vanes (NGV) at three different spanwise locations; pitchwise static pressure distributions downstream of the NGV at four axial locations on the stator platform.


2021 ◽  
Author(s):  
Valentin Vikhorev ◽  
Pär Nylander ◽  
Valery Chernoray ◽  
Jonas Larsson ◽  
Oskar Thulin

Abstract This paper presents experimental and numerical CFD studies of the aerodynamics of a turbine rear structure (TRS). The TRS test geometry is an engine-realistic state-of-the-art design with a polygonal outer case, recessed engine mount bumps, and three different vane types: regular vanes, bump vanes in bump sectors, and thick vanes. Using three different sector types simultaneously was found to be crucial for the inlet boundary conditions. Experiments were performed in a modern rotating test facility with an LPT stage upstream of the TRS. A Reynolds number of 350,000 was used, representative of a TRS in a narrow-body geared turbofan engine. The TRS performance was analyzed both at on- and off-design conditions and a thorough side-by-side comparison of CFD and experiments was performed. Static-pressure-distributions, turning and outlet flow-angles, wakes and losses, and surface-flow visualizations and outlet total pressure contours are presented. The thick vane showed good aerodynamic performance, similar to the regular vane. For the bump vane, the mount bumps were found to generate additional local separations and secondary flows, resulting in extra losses. In the regions with strong secondary flows CFD over-predicts the wakes, whereas the wakes around midspan, where secondary flows have a smaller influence, are predicted well.


1969 ◽  
Vol 91 (2) ◽  
pp. 264-272 ◽  
Author(s):  
D. N. Wormley

A momentum integral analysis is presented for the incompressible, steady, axisymmetric flow in a short vortex chamber of the type commonly used in vortex valves. The analysis is developed with the aid of flow visualization photographs and considers the interaction which occurs between the main vortex core flow and the viscous chamber end wall boundary layers. The radial pressure distributions predicted by the analysis compare favorably with measured end wall static pressure distributions.


AIAA Journal ◽  
1997 ◽  
Vol 35 ◽  
pp. 196-197
Author(s):  
M. T. Islam ◽  
M. A. T. Ali

Author(s):  
Ray R. Taghavi ◽  
Wonjin Jin ◽  
Mario A. Medina

A set of experimental analyses was conducted to determine static pressure drops inside non-metallic flexible, spiral wire helix core ducts, with different bent angles. In addition, Computational Fluid Dynamics (CFD) solutions were performed and verified by comparing them to the experimental data. The CFD computations were carried out to produce more systematic pressure drop information through these complex-geometry ducts. The experimental setup was constructed according to ASHRAE Standard 120-1999. Five different bent angles (0, 30, 45, 60, and 90 degrees) were tested at relatively low flow rates (11 to 89 CFM). Also, two different bent radii and duct lengths were tested to study flexible duct geometrical effects on static pressure drops. FLUENT 6.2, using RANS based two equations - RNG k-ε model, was used for the CFD analyses. The experimental and CFD results showed that larger bent angles produced larger static pressure drops in the flexible ducts. CFD analysis data were found to be in relatively good agreement with the experimental results for all bent angle cases. However, the deviations became slightly larger at higher velocity regimes and at the longer test sections. Overall, static pressure drop for longer length cases were approximately 0.01in.H2O higher when compared to shorter cases because of the increase in resistance to the flow. Also, the CFD simulations captured more pronounced static pressure drops that were produced along the sharper turns. The stronger secondary flows, which resulted from higher and lower static pressure distributions in the outer and inner surfaces, respectively, contributed to these higher pressure drops.


1963 ◽  
Vol 16 (4) ◽  
pp. 620-632 ◽  
Author(s):  
D. J. Maull ◽  
L. F. East

The flow inside rectangular and other cavities in a wall has been investigated at low subsonic velocities using oil flow and surface static-pressure distributions. Evidence has been found of regular three-dimensional flows in cavities with large span-to-chord ratios which would normally be considered to have two-dimensional flow near their centre-lines. The dependence of the steadiness of the flow upon the cavity's span as well as its chord and depth has also been observed.


Author(s):  
Jingjing Luo ◽  
Dieter Brillert

Abstract Dry gas lubricated non-contacting mechanical seals (DGS), most commonly found in centrifugal compressors, prevent the process gas flow into the atmosphere. Especially when high speed is combined with high pressure, DGS is the preferred choice over other sealing alternatives. In order to investigate the flow field in the sealing gap and to facilitate the numerical prediction of the seal performance, a dedicated test facility is developed to carry out the measurement of key parameters in the gas film. Gas in the sealing film varies according to the seal inlet pressure, and the thickness of gas film depends on this fluctuated pressure. In this paper, the test facility, measurement methods and the first results of static pressure measurements in the sealing gap of the DGS obtained in the described test facility are presented. An industry DGS with three-dimensional grooves on the surface of the rotating ring, where experimental investigations take place, is used. The static pressure in the gas film is measured, up to 20 bar and 8,100 rpm, by several high frequency ultraminiature pressure transducers embedded into the stationary ring. The experimental results are discussed and compared with the numerical model programmed in MATLAB, the characteristic and magnitude of which have a good agreement with the numerical simulations. It suggests the feasibility of measuring pressure profiles of the standard industry DGS under pressurized dynamic operating conditions without altering the key components of the seal and thereby affecting the seal performance.


2021 ◽  
Author(s):  
S. J. van der Spuy ◽  
D. N. J. Els ◽  
L. Tieghi ◽  
G. Delibra ◽  
A. Corsini ◽  
...  

Abstract The MinWaterCSP project was defined with the aim of reducing the cooling system water consumption and auxiliary power consumption of concentrating solar power (CSP) plants. A full-scale, 24 ft (7.315 m) diameter model of the M-fan was subsequently installed in the Min WaterCSP cooling system test facility, located at Stellenbosch University. The test facility was equipped with an in-line torque arm and speed transducer to measure the power transferred to the fan rotor, as well as a set of rotating vane anemometers upstream of the fan rotor to measure the air volume flow rate passing through the fan. The measured results were compared to those obtained on the 1.542 m diameter ISO 5801 test facility using the fan scaling laws. The comparison showed that the fan power values correlated within +/− 7% to those of the small-scale fan, but at a 1° higher blade setting angle for the full-scale fan. To correlate the expected fan static pressure rise, a CFD analysis of the 24 ft (7.315 m) diameter fan installation was performed. The predicted fan static pressure rise values from the CFD analysis were compared to those measured on the 1.542 m ISO test facility, for the same fan. The simulation made use of an actuator disc model to represent the effect of the fan. The results showed that the predicted results for fan static pressure rise of the installed 24 ft (7.315 m) diameter fan correlated closely (smaller than 1% difference) to those of the 1.542 m diameter fan at its design flowrate but, once again, at approximately 1° higher blade setting angle.