Astro-E2 mission: the third X-ray observatory in the 21st century

Author(s):  
Hajime Inoue
Keyword(s):  
X Ray ◽  
1989 ◽  
Vol 28 (04) ◽  
pp. 124-128 ◽  
Author(s):  
J. Spitz ◽  
N. Clemenz ◽  
K. Tittel ◽  
H. Weigand

In addition to its established oncological indications the sensitivity of bone scintigraphy is of steadily increasing significance in traumatology. Inactivity- induced osteoporosis plays a major role during the immobilization period in the plaster cast. In the region of the joints remodelling intensity may reach such a high level that the non-injured bone shows a higher rate of accumulation than the fracture. This process already begins between the third and fourth week of immobilization. The highest uptake is found after fracture of the scaphoid bone at the end of twelve weeks of immobilization. Control scintigraphies at intervals of several days are indicated to differentiate between various clinical conditions (pseudoarthrosis, activated osteoarthrosis, algodystrophy in case of doubtful x-ray results).


2018 ◽  
Vol 50 (1) ◽  
pp. 295-296
Author(s):  
Peter Pabisch

Abstract The three scholarly works of recent years illuminate the versatility of their main editor Albrecht Classen in the interdisciplinary world of comparative studies, in literature and language studies. Together with his colleague Eva Parra-Membrives he offers insights on trivial literature also in view of bestsellers concerning the first two works under discussion here. The third work on multilingualism in the middle ages he edited alone. For all the works he found an impressive number of contributors who fill the chalice of offerings in a most versatile canon of topics.


2020 ◽  
Vol 36 (4) ◽  
pp. 1043-1055
Author(s):  
Gaby Umbach

This article1 offers reflections on the use of data as evidence in 21st century policy-making. It discusses the concept of evidence-informed policy-making (EIPM) as well as the governance and knowledge effects of data as evidence. With this focus, it interlinks the analysis of statistics and politics. The paper first introduces the concept of EIPM and the impact of evidence use. Here it focusses on science and knowledge as resources in policy-making, on the institutionalisation of science advice and on the translation of information and knowledge into evidence. The second part of the article reflects on data as evidence. This part concentrates on abstract and concrete functions of data as governance tools in policy-making, on data as a robust form of evidence and on the effects of data on knowledge and governance. The third part highlights challenges for data as evidence in policy-making, among them, politicisation, transparency, and diversity as well as objectivity and contestation. Finally, the last part draws conclusions on the production and use of data as evidence in EIPM. Throughout the second part of the reflections, reference is made to Walter Radermacher’s 2019 matrix of actors and activities related to data, facts, and policy published in this journal.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Mingchen Zou ◽  
Haotian Wu ◽  
Shuangquan Yao ◽  
Dong Ren ◽  
Song Liu ◽  
...  

Abstract Background This study was done to observe the incidence of Osteo-line on the femur neck and to explore the clinical application of Osteo-line in osteotomy. Methods Eighty-nine adult femur specimens were selected to observe the incidence of Osteo-line on the femur neck. From August 2015 to January 2019, a total of 278 patients who completed unilateral hip arthroplasty at the Third Hospital of Hebei Medical University were retrospectively included. Patients who accepted osteotomy via Osteo-line on the femur neck were defined as the experimental group (n = 139), and patients who accepted osteotomy via traditional method (The femoral distance 1.5 cm above the trochanter was retained for osteotomy by visual inspection.) were defined as the control group (n = 139). According to the postoperative pelvic X-ray, Photoshop was used to evaluate the leg length discrepancy (LLD) by the CFR-T-LT method. Results Among the 89 specimens, the incidence of anterior Osteo-line was 75.28%, and the incidence of posterior Osteo-line was 100%. According to the clinical application results, the incidence of anterior Osteo-line on the femur neck was 80%, and the incidence of posterior Osteo-line was 100%. The Osteo-line was clearer than those on the femoral specimens. Twenty-six cases had LLD greater than 1 cm (9.29%), including 2 cases in the experimental group and 24 cases in the control group. The average postoperative LLD in the experimental group (0.19 ± 0.38 mm) was significantly shorter than in the control group (0.54 ± 0.51 mm)(P = 0.005). Conclusion The incidence of Osteo-line on the femur neck was high, and patients who accepted osteotomy via Osteo-line on the femur neck can achieve shorter postoperative LLD than the control group.


1998 ◽  
Vol 164 ◽  
pp. 339-340
Author(s):  
E. B. Fomalont ◽  
C. F. Bradshaw ◽  
B. J. Geldzahler

AbstractFrom three VLBA observations at 5 GHz, spanning 13 months, we have measured the trigonometric parallax of Sco X-1 of 0.23 ± 0.28 mas; hence its distance is > 1300 pc. This supports the hypothesis that the the x-ray luminosity is near the Eddington Limit.All three VLBA observations show a radio core of flux density 0.5 mJy and size < 4 mas. However, the third VLBA observation revealed two additional radio components, separated by 12 mas (≈ 20 au) on opposite sides of the radio core. The evolution of these new components is unknown until additional observations can be made. The relative luminosity and separation of the two radio components are inconsistent with the Doppler beaming of two identical ejecta from the radio core.


2000 ◽  
Vol 5 (S1) ◽  
pp. 97-103
Author(s):  
Kathleen A. Dunn ◽  
Susan E. Babcock ◽  
Donald S. Stone ◽  
Richard J. Matyi ◽  
Ling Zhang ◽  
...  

Diffraction-contrast TEM, focused probe electron diffraction, and high-resolution X-ray diffraction were used to characterize the dislocation arrangements in a 16µm thick coalesced GaN film grown by MOVPE LEO. As is commonly observed, the threading dislocations that are duplicated from the template above the window bend toward (0001). At the coalescence plane they bend back to lie along [0001] and thread to the surface. In addition, three other sets of dislocations were observed. The first set consists of a wall of parallel dislocations lying in the coalescence plane and nearly parallel to the substrate, with Burgers vector (b) in the (0001) plane. The second set is comprised of rectangular loops with b = 1/3 [110] (perpendicular to the coalescence boundary) which originate in the coalescence boundary and extend laterally into the film on the (100). The third set of dislocations threads laterally through the film along the [100] bar axis with 1/3<110>-type Burgers vectors These sets result in a dislocation density of ∼109 cm−2. High resolution X-ray reciprocal space maps indicate wing tilt of ∼0.5º.


2006 ◽  
Vol 527-529 ◽  
pp. 875-878 ◽  
Author(s):  
Seung Yong Lee ◽  
Jang Sub Lee ◽  
Tae Hong Kim ◽  
Sung Yong Choi ◽  
Hak Jong Kim ◽  
...  

We report on the die bonding processes and how the surface roughness and metallization schemes affect the processes of die bonding in 4H-SiC device fabrication using a soldering test and die shear test (DST) with differently prepared 4H-SiC samples. The first set of samples (FZ#1 and FZ#2) was capped with sequentially evaporated Ti and Au on an annealed Ni layer. The second set of samples (FZ#3 and FZ#4) and the third set of samples (FZ#5 and FZ#6) were prepared by 4μm-thick Au electroplating on an annealed Ni layer and an un-annealed Ni layer, respectively. The quality of the soldering, such as the solder coverage, void, and adhesion, was characterized by optical microscope, X-ray microprobe, and DST. We found that the samples (FZ#4 and FZ#6) deposited by Au electroplating on C-face (bottom-side) 4H-SiC provided a satisfactory result for the tests of solder coverage, void, and DST and also realized the cleaning process prior to the electroplating and soldering was the most crucial in the die packaging processes of vertical structure devices. The void fraction measured by X-ray microprobe for the samples, FZ#4 and FZ#6 was 2.2% (average for 5 samples) and 0.8% (average for 3 samples), respectively.


1991 ◽  
Vol 46 (5) ◽  
pp. 566-572 ◽  
Author(s):  
Axel Gudat ◽  
Peter Höhn ◽  
Rüdiger Kniep ◽  
Albrecht Rabenau

The isotypic ternary compounds Ba3[MoN4] and Ba3[WN4] were prepared by reaction of the transition metals with barium (Ba3N2, resp.) under nitrogen. The crystal structures were determined by single crystal X-ray diffraction: Ba3[MoN4] (Ba3[WN4]): Pbca; Z = 8; a = 1083.9(3) pm (1091.8(3) pm), b = 1030.3(3) pm (1037.5(3) pm), c = 1202.9(3) pm (1209.2(4) pm). The structures contain isolated tetrahedral anions [MN4]6- (M = Mo, W) which are arranged in form of slightly distorted hexagonal layers and which are stacked along [010] with the sequence (···AB···). Two of the three Ba atoms are situated between, the third one is placed within the layers of [MN4]-groups. In this way the structures can be derived from the Na3As structure type.


1992 ◽  
Vol 267 ◽  
Author(s):  
Ana M De Andres ◽  
Isabel MuÑOZ

ABSTRACTNineteen roman ceramic sherds found near Salobreña (Granada, Spain), in the western coast of the Mediterranean Sea, as well as different ceramic clays from the surroundingsare studied. Both clays and ceramic sherds are characterizad by X-ray diffraction and spectrometry, differential thermal analysis, and scanning electron and optical microscopies. A good number of the ceramic pieces, among which some “Terrae Sigillatae”, have a composition similar to that of the local clays and, thus, have been probably manufactured at Salobreña. Only a few of them have a foreign origin. For most of them, the firing temperature was about 800-850 °C, although some have been produced at 900-1000 °C, and some others at 1000-1100 °C. It is concluded that Salobreña appearsto have been an important settlement just in the third century of the Christian era.


1987 ◽  
Vol 40 (7) ◽  
pp. 1147 ◽  
Author(s):  
EJ Oreilly ◽  
G Smith ◽  
CHL Kennard ◽  
TCW Mak

The crystal structures of (2-formyl-6-methoxyphenoxy)acetic acid (1), diaquabis [(2-formyl-6-methoxyphenoxy) acetato ]zinc(11) (2), tetraaquabis [(2-chlorophenoxy) acetato ]zinc(11) (3), triaquabis [(2-chlorophenoxy) acetato ]cadmium(11) dihydrate (4) and lithium (2-chloro- phenoxy )acetate 1.5 hydrate (5) have been determined by X-ray diffraction. The acid (1) forms centrosymmetric hydrogen-bonded cyclic dimers [O…0, 2.677(6) �] which are non-planar. Complex (2) is six-coordinate with two waters [Zn- Ow , 1.997(2) �] and four oxygens from two asymmetric bidentate carboxyl groups [Zn-O, 2.073, 2.381(2) �] completing a skew trapezoidal bipyramidal stereochemistry. Complex (5) is also six-coordinate but is octahedral, with two trans-related unidentate carboxyl oxygens [mean Zn-O, 2.134(9) �] and four waters [mean Zn-O, 2.081(9) �]. The seven-coordinate complex (4) has crystallographic twofold rotational symmetry relating two :symmetric bidentate acid ligands [ Cd -O, 2.26, 2 48(:) �] and two waters [ Cd -O, 2.34(2) �] while the third water lies on this axis [ Cd -O, 2.27(2) �]. In contrast to the monomers (2)-(4), complex (5) is polymeric with tetrahedral lithium coordinated to one water and three carboxylate oxygens [mean Li-0, 1.95(1) �]. The essential conformation of the free acid is retained in complexes (2), (3) and (4) but in (5), it is considerably changed.


Sign in / Sign up

Export Citation Format

Share Document