Dual confocal ultrasound system for shear wave elastography

2008 ◽  
Vol 123 (5) ◽  
pp. 3914-3914
Author(s):  
Michael D. Gray ◽  
James S. Martin ◽  
Peter H. Rogers
2017 ◽  
Vol 43 (8) ◽  
pp. 1596-1606 ◽  
Author(s):  
Mihai Strachinaru ◽  
Johan G. Bosch ◽  
Bas M. van Dalen ◽  
Lennart van Gils ◽  
Antonius F.W. van der Steen ◽  
...  

2021 ◽  
Vol 3 ◽  
pp. 3-9
Author(s):  
Shamrendra Narayan ◽  
Nilotpal Choudhury ◽  
Ajai Kumar Singh ◽  
Tushar Anand ◽  
Gaurav Raj ◽  
...  

Objectives: The performance of shear wave elastography (SWE) for peripheral nerve pathology, predominantly compressive neuropathy, has been studied with the median nerve, sciatic nerve, and tibial nerve. However, studies for ulnar nerve are limited in literature. The aim of the study was to study the performance of SWE for ulnar nerve in arm by analyzing the correlation of elasticity value by two transducers of the same ultrasound system. Material and Methods: This was a prospective observational study. Elasticity of ulnar nerve was measured in the mid-arm and supracondylar region in longitudinal and transverse planes with two different transducers of the same ultrasound system. The reliability of measurement was assessed by interclass correlation of values obtained. Results: Ninety-two ulnar nerve measurement sets were analyzed. The ages of the patients ranged from 14 years to 76 years, with a median age of 50. The SWE values obtained by two probes showed a weak interclass correlation coefficient value <0.5. Conclusion: Quantitative SWE measurements of the ulnar nerve in the arm by two transducers showed a weak interclass correlation. It should be used with caution as a diagnostic tool with a universally acceptable cut off values.


Author(s):  
Anders Batman Mjelle ◽  
Anesa Mulabecirovic ◽  
Roald Flesland Havre ◽  
Edda Jonina Olafsdottir ◽  
Odd Helge Gilja ◽  
...  

Abstract Purpose Liver elastography is increasingly being applied in screening for and follow-up of pediatric liver disease, and has been shown to correlate well with fibrosis staging through liver biopsy. Because time is of the essence when examining children, we wanted to evaluate if a reliable result can be achieved with fewer acquisitions. Materials and Methods 243 healthy children aged 4–17 years were examined after three hours of fasting. Participants were divided into four age groups: 4–7 years; 8–11 years; 12–14 years and 15–17 years. Both two-dimensional shear wave elastography (2D-SWE; GE Logiq E9) and point shear wave elastography (pSWE; Samsung RS80A with Prestige) were performed in all participants, while transient elastography (TE, Fibroscan) was performed in a subset of 87 children aged 8–17 years. Median liver stiffness measurement (LSM) values of 3, 4, 5, 6, 7, and 8 acquisitions were compared with the median value of 10 acquisitions (reference standard). Comparison was performed for all participants together as well as within every specific age group. We investigated both the intraclass correlation coefficient (ICC) with absolute agreement and all outliers more than 10 %, 20 % or ≥ 0.5 or 1.0 kPa from the median of 10 acquisitions. Results For all three systems there was no significant difference between three and ten acquisitions, with ICCs ≥ 0.97. All systems needed 4 acquisitions to achieve no LSM deviating ≥ 1.0 kPa of a median of ten. To achieve no LSM deviating ≥ 20 % of a median of ten acquisitions, pSWE and TE needed 4 acquisitions, while 2D-SWE required 6 acquisitions. Conclusion Our results contradict recommendations of 10 acquisitions for pSWE and TE and only 3 for 2D-SWE.


2019 ◽  
Author(s):  
Mihaela Vlad ◽  
Ioana Golu ◽  
Maria Oprea ◽  
Daniela Amzar ◽  
Melania Balas ◽  
...  

2016 ◽  
Vol 25 (4) ◽  
pp. 525-532 ◽  
Author(s):  
Monica Lupșor-Platon ◽  
Radu Badea ◽  
Mirela Gersak ◽  
Anca Maniu ◽  
Ioana Rusu ◽  
...  

There has been great interest in the development of non-invasive techniques for the diagnosis of liver fibrosis in chronic liver diseases, including ultrasound elastographic methods. Some of these methods have already been adequately studied for the non-invasive assessment of diffuse liver diseases. Others, however, such as two-dimensional Shear Wave Elastography (SWE), of more recent appearance, have yet to be validated and some aspects are for the moment incompletely elucidated. This review discusses some of the aspects related to two-dimensional SWE: the examination technique, the examination performance indicators, intra and interobserver agreement and clinical applications. Recommendations for a high-quality examination technique are formulated. Key words:  –  –  – Two-dimensional Shear Wave Elastography. Abbreviations: 2D- SWE: Two-dimensional Shear Wave Elastography; 3D- SWE: Three-dimensional Shear Wave Elastography; AUROC: area under the receiver operating characteristic curves; ARFI Acoustic Radiation Force Impulse Elastography; EFSUMB: European Federation of Societies for Ultrasound in Medicine and Biology; HVPG: hepatic venous pressure gradient; LS: liver stiffness; LR: likelihood ratio; NPV: negative predictive value; PPV: positive predictive value; ROI: region of interest; RT-E: Real Time-Elastography; Se: sensitivity; Sp: specificity; TE: Transient Elastography; US: ultrasound; VM: valid measurement; E: Young’s modulus