Applying a most probable number method for enumerating planktonic, dissimilatory, ammonium-producing, nitrate-reducing bacteria in oil field waters

2005 ◽  
Vol 51 (8) ◽  
pp. 725-729 ◽  
Author(s):  
Ruth E Eckford ◽  
Phillip M Fedorak

A most probable number (MPN) method was used to enumerate dissimilatory ammonium-producing, nitrate-reducing bacteria (DAP-NRB) in oil field waters and to determine whether they were stimulated by nitrate addition used to control hydrogen sulfide production. An ammonium production medium with 5 carbon and energy sources (acetate, glucose, glycerol, pyruvate, and succinate) and nitrate was used in a 3-tube MPN procedure to enumerate DAP-NRB. These bacteria were detected in 12 of 18 oil field water samples, but they were seldom detected in wellhead samples. Three oil field water samples were amended with nitrate in serum bottles and the numbers of different NRB were determined over a 38-day incubation time. This amendment stimulated increases in the numbers of heterotrophic NRB and autotrophic nitrate-reducing, sulfide-oxidizing bacteria, but DAP-NRB remained a minor portion of these communities. Overall, DAP-NRB were present in many of the oil field waters that were examined but their numbers were low. It appears that DAP-NRB would play a minor role in the consumption of nitrate injected into oil field waters for the control of hydrogen sulfide production.Key words: heterotroph, nitrate-reducing bacteria, dissimilatory nitrate reduction, ammonium, petroleum.

2021 ◽  
Vol 26 (1) ◽  
pp. 1-16
Author(s):  
Julian Esteban Másmela-Mendoza ◽  
Luz Marina Lizarazo Forero

The objective of study was to isolate and determine the identity of denitrifying bacteria from limnetic areas of Lake Tota (Colombian Andes) with and without rainbow trout production activities. We examined the relationships between the lake’s physicochemical factors (oxygen, nitrogen, and phosphorus content) and two bacterial communities (denitrifying bacteria and coliforms). Water samples were taken 20m below the surface from July to September at five limnetic zones; two of which were close to rainbow trout farming areas. In each zone, the concentrations of oxygen, nitrogen, and phosphorus were measured. To identify and quantify the abundance of bacteria, the most probable number (MPN) technique was used, employing minimal medium for denitrifying bacteria and medium for nitrate reducing bacteria (NRB). A greater number of denitrifying bacteria were found in the fish farming zones, identifying bacteria of the genera Bacillus, Pseudomonas, Nocardia, and Streptomyces. The number of nitrate-reducing bacteria revealed statistically significant differences throughout the sampling period, increasing from July to September and was related to a decrease in precipitation. The density of NRB and total phosphorus were directly correlated. High bacterial densities of denitrifyingbacteria and coliforms are indicative of changes from oligotrophic to eutrophic states in the studied limnetic areas.


1974 ◽  
Vol 20 (11) ◽  
pp. 1487-1492 ◽  
Author(s):  
Q. D. Skinner ◽  
J. C. Adams ◽  
P. A. Rechard ◽  
A. A. Beetle

Nitrate-reducing bacteria, sulfate-reducing bacteria, fluorescent bacteria, and the total viable count were enumerated in three stream systems within a high mountain watershed over a period of two winters and two summers from 1970 to 1972. Spread plate and most probable number procedures showed that the number of fluorescent bacteria, sulfate-reducing bacteria, nitrate-reducing bacteria, and the total count were generally constant throughout the year at the lowest sampling site on the stream systems. However, in some cases and for short periods of time, the numbers of these bacteria appeared to be influenced by recreational use of the land and stream flow. For example, denitrifying bacteria increased in number during the winter recreational period and gave the lowest counts in July.


1991 ◽  
Vol 24 (2) ◽  
pp. 143-147 ◽  
Author(s):  
N. A. Grabow ◽  
R. Kfir ◽  
W. O. K. Grabow

A new quantitative method for the enumeration of Legionella bacteria in water is described. Appropriate tenfold serial dilutions of water samples concentrated by membrane filtration are plated in triplicate on buffered charcoal yeast extract agar. After incubation for 3 days representative smears from individual plates are tested for the presence of Legionella by direct fluorescent antibody staining. The number of positive plates in each dilution is used to calculate the Legionella count by means of conventional most probable number statistics. In comparative tests on a variety of water samples this method yielded significantly higher counts than previously used procedures.


2019 ◽  
Vol 9 (4) ◽  
pp. 683-693
Author(s):  
Richard Onyuthi Apecu ◽  
Lucas Ampaire ◽  
Edgar Mugema Mulogo ◽  
Fred Norman Bagenda ◽  
Afsatou Traore ◽  
...  

Abstract The aim of this study was to assess the bacteriological quality of water sources in the two rural areas of Uganda using the compartment bag test (CBT). In total, 200 water samples were collected from 69 different water sources and processed within 6 h of collection. Positive and negative controls were processed each day together with water samples. Physical parameters were measured in situ. Descriptive statistics were used to generate mean, minimum, maximum, standard deviations and percentages. The results indicated that 29% of the water sources met the National Standards and World Health Organization (WHO) Guidelines for drinking water. Sixty percent of the borehole, 44% of gravitational flow taps and 14% of roof rain water met the required standards. Of the open water sources, 75% of the rivers, 50% of open channels and 43% of unprotected dug wells plus 25% of protected springs and 9% of gravitational flow schemes had most probable number counts >100 Escherichia coli/100 mL of water. Most of the water sources in the study areas were not fit for human consumption without prior treatment. The CBT was found to be robust and easy to use in all field situations. The mean physical parameters of water sources were within the acceptable limits.


2019 ◽  
Author(s):  
Goyitom Gebremedhn ◽  
Abera Aregawi Berhe ◽  
Abraham Aregay Desta ◽  
Lemlem Legesse

Abstract Background Fecal contamination of drinking water sources is the main cause of diarrhea with estimated incidence of 4.6 billion episodes and 2.2 million deaths every year. Methods A total of 145 water samples of different source type were collected from different areas in Tigray region from August 2018 to January 2019. The water samples from each site were selected purposively which involved sampling of water sources with the highest number of users and functionality status during the study period. Most Probable Number (MPN) protocol was used for the bacteriological analysis of the samples. Results A total of 145 water samples were collected from six zones in Tigray region, Ethiopia from August 2018 to January 2019. The study indicated that 63(43.5%) of the water samples were detected to have fecal coliform which is E.coli. In Mekelle city, which is the capital city of Tigray region, three in five 34(60.7%) of the collected samples were confirmed to have fecal coliform. Water samples from health facilities were 9.48 times [AOR=9.48, 95%CI: (1.59, 56.18)] more likely to have fecal coliform. Water samples from wells were 10.23 times [AOR=10.23, 95%CI: (2.74, 38.26)] more likely to have fecal coliform than water samples from Tap/Pipe. Similarly, water samples from hand pumps were 22.28 times [AOR=22.28, 95%CI: (1.26, 393.7)] more likely to have fecal coliform than water samples from Tap/Pipe. Water samples reported to be not chlorinated were 3.51 times [AOR=3.51, 95%CI: (1.35, 9.13)] more likely to have fecal coliform than water samples from chlorinated sources. Conclusion In this study all water source, including the chlorinated drinking water sources, were found highly contaminated with fecal origin bacteria. This may be mainly due to constructional defects, poor sanitation inspection, poor maintenance, intermittent water supply and irregular chlorination.


2000 ◽  
Vol 66 (1) ◽  
pp. 154-162 ◽  
Author(s):  
David E. Cummings ◽  
Anthony W. March ◽  
Benjamin Bostick ◽  
Stefan Spring ◽  
Frank Caccavo ◽  
...  

ABSTRACT Mining-impacted sediments of Lake Coeur d'Alene, Idaho, contain more than 10% metals on a dry weight basis, approximately 80% of which is iron. Since iron (hydr)oxides adsorb toxic, ore-associated elements, such as arsenic, iron (hydr)oxide reduction may in part control the mobility and bioavailability of these elements. Geochemical and microbiological data were collected to examine the ecological role of dissimilatory Fe(III)-reducing bacteria in this habitat. The concentration of mild-acid-extractable Fe(II) increased with sediment depth up to 50 g kg−1, suggesting that iron reduction has occurred recently. The maximum concentrations of dissolved Fe(II) in interstitial water (41 mg liter−1) occurred 10 to 15 cm beneath the sediment-water interface, suggesting that sulfidogenesis may not be the predominant terminal electron-accepting process in this environment and that dissolved Fe(II) arises from biological reductive dissolution of iron (hydr)oxides. The concentration of sedimentary magnetite (Fe3O4), a common product of bacterial Fe(III) hydroxide reduction, was as much as 15.5 g kg−1. Most-probable-number enrichment cultures revealed that the mean density of Fe(III)-reducing bacteria was 8.3 × 105 cells g (dry weight) of sediment−1. Two new strains of dissimilatory Fe(III)-reducing bacteria were isolated from surface sediments. Collectively, the results of this study support the hypothesis that dissimilatory reduction of iron has been and continues to be an important biogeochemical process in the environment examined.


2021 ◽  
Vol 27 (2) ◽  
Author(s):  
Alok Kumar Singh ◽  
Anand Prakash Singh ◽  
Sanjay Srivastava

In India source of drinking water at Varanasi city for common people are tap water, well, hand pump, Ganga river and stored tank water collected from bore well. All water samples were studied to assess their bacteriological characteristics and suitability for potable purposes. A cross-sectional epidemiological method was adopted to investigate the drinking water of six different sites of Varanasi city. The bacteriological examination of water samples included the most probable number of presumptive coliforms, faecal coliforms, and total bacterial count. The results showed that the total coliform count was detected in all the site. In all the methods coliforms presence was indicated. Maximum number of coliform observed in all the seasons, were from river and well water followed by hand pump, tap water and stored tank. The most common group of indicator organisms used in water quality monitoring are coliforms. These organisms are representative of bacteria normally present in the intestinal tract of mammals including human. Contamination of water may occur through different way like sewage disposal in the river, seepage of bathing near sites, fecal excreta of human, bird and other animals. Improving and expanding the existing water treatment and sanitation systems are more likely to provide good, safe and sustainable sources of water in the long term.


2020 ◽  
Vol 36 (2) ◽  
pp. 75-77
Author(s):  
Anindita Bhowmik ◽  
Sunjukta Ahsan

Majority of the population of Bangladesh depend on tap or surface water as their source of water supply. This study was carried out to examine the microbial quality of both water and soil collected from different places using the multiple tube fermentation technique to determine coliform count by the most probable number (MPN) method in brilliant green lactose broth (BGLB) media.Inoculum from positive tubes of the presumptive test were further transferred on eosinemethylene blue (EMB) and MacConkey agar.The organisms isolated were further characterized using biochemical tests. Out of 93 water samples, 30 (32.26%) indicated the presence of lactose fermenter and gas producer in all 3 tubes of dilution series using inoculum quantities of 1.0, 0.1 and 0.01 ml, whereas out of 85 soil samples, 45 (52.94%) showed acid and gas production in all 3 tubes of dilution series.Among 85 soil samples, 40 samples that contained at least one positive in each dilution series and among 93 water samples, 31 samples that contained at least one positive in each dilution series were further re-identified with biochemical tests.This study showed 30.59% soil isolates and 26.88% water isolates were Escherichia coli which highlighted the fact that both water and soil act as a major reservoir of E.coli, which indicates possible fecal contamination as well as presence of potentially pathogenic E. coli. Bangladesh J Microbiol, Volume 36 Number 2 December 2019, pp 75-77


Sign in / Sign up

Export Citation Format

Share Document