LIF DETECTION OF TRACE SPECIES IN WATER USING DIFFERENT UV LASER WAVELENGTHS

2007 ◽  
Vol 17 (04) ◽  
pp. 689-695
Author(s):  
ANNA V. SHARIKOVA ◽  
DENNIS K. KILLINGER

We have conducted studies of deep UV laser-induced fluorescence (LIF) for the reagentless detection of trace species and Dissolved Organic Compounds (DOC's) in water. Our LIF detection system had two interchangeable UV lasers, 266 nm and 355 nm, illuminating a flow cell containing a water sample. The fluorescence emitted at 90 degrees to the laser beam was collected by focusing optics, passed through cut-off and interference filters with 21 optical bandpass channels (240–680 nm ), and detected by a photomultiplier tube (PMT). The samples analyzed by the system included bottled, tap and river water; we have also worked with biological and chemical species (Bacillus Globigii, malathion). In terms of the excitation wavelength, it was observed that the deep UV excitation resulted in spectra that contained more features, and had better separation of the LIF from the Raman peak, thus enhancing the detection of unique spectral features.

1996 ◽  
Author(s):  
Klony S. Lieberman ◽  
Hanan Terkel ◽  
Michael Rudman ◽  
A. Ignatov ◽  
Aaron Lewis

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
D. Winzen ◽  
V. Hannen ◽  
M. Bussmann ◽  
A. Buß ◽  
C. Egelkamp ◽  
...  

AbstractThe $$^2{\mathrm{S}}_{1/2}{-}^2{\mathrm{P}}_{{1}/2}$$ 2 S 1 / 2 - 2 P 1 / 2 and $$^2{\mathrm{S}}_{1/2}{-}^2{\mathrm{P}}_{{3}/2}$$ 2 S 1 / 2 - 2 P 3 / 2 transitions in Li-like carbon ions stored and cooled at a velocity of $$\beta \approx 0.47$$ β ≈ 0.47 in the experimental storage ring (ESR) at the GSI Helmholtz Centre in Darmstadt have been investigated in a laser spectroscopy experiment. Resonance wavelengths were obtained using a new continuous-wave UV laser system and a novel extreme UV (XUV) detection system to detect forward emitted fluorescence photons. The results obtained for the two transitions are compared to existing experimental and theoretical data. A discrepancy found in an earlier laser spectroscopy measurement at the ESR with results from plasma spectroscopy and interferometry has been resolved and agreement between experiment and theory is confirmed.


The Analyst ◽  
2020 ◽  
Vol 145 (7) ◽  
pp. 2580-2585 ◽  
Author(s):  
Hisashi Shimizu ◽  
Shigenori Takeda ◽  
Kazuma Mawatari ◽  
Takehiko Kitamori

Ultrasensitive detection of nonlabelled bovine serum albumin is performed in micro/nanofluidic chips using a photothermal optical phase shift (POPS) detection system.


2020 ◽  
Vol 520 ◽  
pp. 146307 ◽  
Author(s):  
Raul Zazo ◽  
Javier Solis ◽  
José A. Sanchez-Gil ◽  
Rocio Ariza ◽  
Rosalia Serna ◽  
...  

1987 ◽  
Vol 115 ◽  
pp. 340-340
Author(s):  
J. Echevarría ◽  
J. Bohigas ◽  
J. Torrelles ◽  
J. Cantó

Using the Mepsicron detection system, we obtained images of the region around Herbig-Haro objects 1 and 2. These images were taken with interference filters centred on Hα, on the red continuum (6648 A) and on the [S II] line at 6731 A.


2018 ◽  
Vol 20 (22) ◽  
pp. 15015-15021 ◽  
Author(s):  
Dongyuan Yang ◽  
Yanjun Min ◽  
Zhichao Chen ◽  
Zhigang He ◽  
Kaijun Yuan ◽  
...  

The ultrafast excited-state dynamics of 2,5-dimethylpyrrole is studied in detail following deep UV excitation.


2019 ◽  
Vol 28 (2) ◽  
pp. 194-203
Author(s):  
Yuxi Deng ◽  
Xianzhe Liu ◽  
Weijian Yuan ◽  
Honglong Ning ◽  
Sha Tao ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document