Dynamic Behavior of Transmission Tower-Line Systems Subjected to Insulator Breakage

2018 ◽  
Vol 18 (03) ◽  
pp. 1850036 ◽  
Author(s):  
Jia-Xiang Li ◽  
Hong-Nan Li ◽  
Xing Fu

Ice loads attached to a transmission tower-line system can not only increase the vertical loads on the insulators, but also cause flashover to occur more easily. Both effects can lead to an increased probability of insulator breakage. In this paper, a finite-element model of a transmission tower-line system with three towers and four span lines under the ice loads is established. Dynamic analyses of the tower-line system after insulator breakage are performed to study the dynamic responses of the system and its failure process. In addition, a parametric analysis is conducted to investigate the influence of span length and insulator length on the vibration of the system and the failure mode. The results show that a larger ice load can lead to more severe vibration of the tower-line system due to the insulator breakage. Moreover, as the span length increases, the insulator breakage can result in more serious consequences and even the cascading collapse of the transmission tower-line system. This study provides crucial reference for preventing the failure of transmission tower-line systems in heavy ice regions.

2015 ◽  
Vol 744-746 ◽  
pp. 248-252
Author(s):  
Wen Ping Xie ◽  
Bo Chen ◽  
Peng Yun Li ◽  
Xiao Fen Gong

The research on dynamic responses of a transmission tower under monsoon wind is actively carried out in this study. A real transmission tower-line system constructed in the southern coastal areas of China is taken as an example to investigate the structural performance subjected to monsoon wind. The finite element model of the transmission tower-line system is established with the aiding of commercial package. The equation of motion of the transmission tower-line system under monsoon wind is established. The dynamic wind loading are applied on the tower-line system to examine the structural responses.


2010 ◽  
Vol 10 (03) ◽  
pp. 461-481 ◽  
Author(s):  
FENGLI YANG ◽  
JINGBO YANG ◽  
JUNKE HAN ◽  
DONGJIE FU

Ice shedding from conductors may easily induce electrical and mechanical accidents, which cause a serious threat to the safe operation of transmission lines. In this paper, a 3D finite element model of tower-conductor-ground wire-insulator system was established in ANSYS, and the dynamic responses of ice shedding under different cases were analyzed for a transmission tower-line system. The computed jumping heights are in excellent agreement with the experimental values of a two span conductors model. Many variables were considered in the ice-shedding simulations that include tower-line coupled effect, phase combination of the ice-shedding conductors, thickness of the accreted ice, length of the ice-shedding span as well as elevation difference. Influences of all the variables on the dynamic responses of jumping heights, loads at the end of insulators and the forces of transmission tower were studied. Ice-shedding simulations of an actual 500 kV transmission line section which experience failure under ice shedding in 2008 were performed. The results show that stress ratios of members at the tower head under design ice thickness exceed the limiting values when the amount of shedding ice is large. For ice shedding at the top phase conductors, the jumping height and unbalanced tension at the end of insulator can be reduced by applying interphase spacers in triangular arrangement. The tower is in a safe state under the load of the design ice thickness. In order to prevent ice-shedding accidents, interphase spacers should be used, and the weak members at the tower head should be strengthened according to the calculated load values at the end of insulators.


2021 ◽  
Vol 9 ◽  
Author(s):  
Jiaxiang Li ◽  
Biao Wang ◽  
Jian Sun ◽  
Shuhong Wang ◽  
Xiaohong Zhang ◽  
...  

Ice shedding causes transmission lines to vibrate violently, which induces a sharp increase in the longitudinal unbalanced tension of the lines, even resulting in the progressive collapse of transmission towers in serious cases, which is a common ice-based disaster for transmission tower-line systems. Based on the actual engineering characteristics of a 500 kV transmission line taken as the research object, a finite element model of a two-tower, three-line system is established by commercial ANSYS finite element software. In the modeling process, the uniform mode method is used to introduce the initial defects, and the collapse caused by ice shedding and its influencing parameters are systematically studied. The results show that the higher the ice-shedding height is, the greater the threat of ice shedding to the system; furthermore, the greater the span is, the shorter the insulator length and the greater the dynamic response of the line; the impact of ice shedding should be considered in the design of transmission towers.


2014 ◽  
Vol 2014 ◽  
pp. 1-10
Author(s):  
Li Tian ◽  
Wenming Wang ◽  
Hui Qian

The effect analysis of strain rate on power transmission tower-line system under seismic excitation is studied in this paper. A three-dimensional finite element model of a transmission tower-line system is created based on a real project. Using theoretical analysis and numerical simulation, incremental dynamic analysis of the power transmission tower-line system is conducted to investigate the effect of strain rate on the nonlinear responses of the transmission tower and line. The results show that the effect of strain rate on the transmission tower generally decreases the maximum top displacements, but it would increase the maximum base shear forces, and thus it is necessary to consider the effect of strain rate on the seismic analysis of the transmission tower. The effect of strain rate could be ignored for the seismic analysis of the conductors and ground lines, but the responses of the ground lines considering strain rate effect are larger than those of the conductors. The results could provide a reference for the seismic design of the transmission tower-line system.


Author(s):  
Xing Fu ◽  
Wen-Long Du ◽  
Hong-Nan Li ◽  
Wen-Ping Xie ◽  
Kai Xiao ◽  
...  

The gust response factors (GRFs) of transmission towers in current standards are reviewed for synoptic winds. The collapse of most transmission towers has occurred under the high-intensity wind (HIW) caused by events such as typhoons, hurricanes, and downbursts. Thus, this paper studies the GRF of a transmission tower under the typhoon. First, the definition of GRF and its extended form for the transmission towers are developed. Then the wind speed simulation of a typhoon event is introduced. Based on the structural health monitoring (SHM) system installed on tower #32, the measured GRFs under the super typhoon Mangkhut are calculated. Then the finite element model (FEM) of the transmission tower-line system is established to simulate the dynamic response to further calculate the GRFs, which agrees well with the field measurements. Both the field measurement and simulation results show that the GRFs under the typhoon are larger than those under the synoptic wind and that the recommended GRFs in the Chinese standard underestimate the peak responses. Finally, a parametric analysis is performed, which demonstrates that the turbulence intensity, wind speed, and power-law exponent all have great effects on the GRFs of transmission towers. In the HIW-prone areas, it is recommended that the characteristics of the HIW can be considered in improving the GRF values to guarantee the structural safety of transmission towers.


2020 ◽  
Vol 23 (10) ◽  
pp. 2110-2120
Author(s):  
Li Tian ◽  
Xin Zhang ◽  
Xing Fu

Numerous transmission towers have collapsed due to experiencing strong winds; therefore, the purpose of this article is to investigate the collapse mechanism and the anti-collapse performance of a long-span transmission tower–line system. The detailed finite element model of a typical tower–line system is established in ABAQUS. A global damage index is proposed to quantitatively estimate the overall damage of the structure and define the collapse criteria. An incremental dynamic analysis is performed to obtain the collapse mechanism and the ultimate capacity of the structure. Subsequently, a fragility analysis for evaluating the anti-collapse performance is conducted due to the uncertainty of wind loads. Eventually, the influence of the wind attack angle and the length of the side spans on the fragility is discussed. The results demonstrate that the proposed global damage index is capable of quantitatively reflecting the overall damage and assessing the ultimate capacity of the structure. In addition, the uncertainty of the wind load has a significant influence on the ultimate capacity and the failure position. Furthermore, the results reveal that the wind attack angle and the length of the side spans have an apparent effect on the fragility of the structure.


2019 ◽  
Vol 19 (06) ◽  
pp. 1950056 ◽  
Author(s):  
Li Tian ◽  
Kunjie Rong ◽  
Kaiming Bi ◽  
Peng Zhang

Failures of transmission tower-line systems have frequently occurred during large earthquakes. It is essential to control the excessive vibrations of transmission tower-line systems to ensure their safe operation in such events. This paper numerically investigates the effectiveness of using a novel bidirectional pounding tuned mass damper (BPTMD) to control the seismic responses of transmission tower-line system when subjected to earthquake ground motions. A finite element model of a typical transmission tower-line system with BPTMD is developed using the commercial software ABAQUS, with the accuracy of the results verified against a previous study. The seismic responses of the system with and without BPTMD are calculated. For comparison, the control effect of using the conventional bidirectional tuned mass damper is also calculated and discussed. Finally, a parametric study is performed to investigate the effects of the mass ratio, seismic intensity, gap size and frequency ratio on the seismic response of the system, while optimal design parameters are obtained.


2014 ◽  
Vol 597 ◽  
pp. 376-379 ◽  
Author(s):  
Feng Lin Gan ◽  
Hai Long Jiang

For wind-induced vibration of transmission tower-line system, the vibration reduction effects are studied based on a new type steel-lead viscoelastic damper. Firstly, Calculate damped coefficient basing on the test of the new type steel-lead viscoelastic damper under slow reversed cyclic horizontal loads. Then, a finite element model of transmission tower was built by using ANSYS. And the time history samples of random fluctuating wind load is obtained with the linear auto-regressive filter law principle. Next, three installation plans of dampers on tower were proposed based on analyzing the working principle damper and the structure of tower. Finally, a wind-induced vibration transient response simulation was performed respectively for the different plans. The influences of SLVD dampers on the displacement and on the acceleration of the controlled nodes were compared. SLVD damper can reduce the top node displacement by about 37.89%. The results indicated that the SLVD damper can suppress the wind-induced vibration. And through comparison, the optimal installation scheme of SLVD dampers is obtained.


2013 ◽  
Vol 327 ◽  
pp. 284-289
Author(s):  
Xiao Guang Hu ◽  
Jing Bo Yang ◽  
Feng Li Yang

Tower-line system of overhead transmission line are sensitive to wind. Therefore, dynamic effect of wind load should be taken into consideration, for instance, wind-induced vibration coefficient. There might be some errors in the calculation of the coefficient in accordance with ‘Load code for the design of building structures’, for its ignoring the irregular figure, scattered masses and coupling effect of tower-line system. Tower-line system is set up in virtual environment, with tower-line coupling considered, and research wind-induced vibration dynamic responses under Davenport wind speed spectrum. Random vibration theory was applied to calculate the coefficient. Whole tower was divided by hight, and calculated segment’s the wind-induced vibration coefficient seprately. Compare the coefficient from Load Code and random vibration theory, the latter with tower-line coupling effect and tower figure considered, is close to the actual.


2021 ◽  
Vol 2021 ◽  
pp. 1-18
Author(s):  
Jiangjun Ruan ◽  
Li Zhang ◽  
Wei Cai ◽  
Daochun Huang ◽  
Jian Li ◽  
...  

Due to the uncontrollable weather conditions, it is difficult to carry out the controllable prototype test to study fatigue damage of transmission tower and armour clamp and the effect evaluation of antigalloping device under actual transmission line galloping. Considering the geometric nonlinearity of the transmission line system, this study proposed an adaptive excitation method to establish the controllable transmission line galloping test system based on the Den Hartog vertical oscillation mechanism. It can skip the complicated process of nonlinear aerodynamic force simulation. An electromagnetic repulsion mechanism based on the eddy current principle was designed to provide periodic excitation for the conductor system according to the adaptive excitation method. The finite element model, including conductor, insulator string, and electromagnetic mechanism, was established. Newmark method and fourth-order Runge-Kutta algorithm were used to complete the integrated simulation calculation. By comparing with the measured data record of the actual transmission line galloping test, the results show that the proposed adaptive galloping excitation system can effectively reconstruct the key characteristics of the actual transmission line galloping, such as amplitude, frequency, galloping mode, and dynamic tension, and make the galloping state controllable. Thus, a series of research about transmission line galloping with practical engineering significance can be carried out.