Spatially Controlled Functionalization and Chemical Manipulation to Fabricate Two-Dimensional Arrays of Gold Nanoparticles onto Indium Tin Oxide

2008 ◽  
Vol 47 (6) ◽  
pp. 5048-5052 ◽  
Author(s):  
Om P. Khatri ◽  
Kuniaki Murase ◽  
Hiroyuki Sugimura
Langmuir ◽  
2012 ◽  
Vol 28 (20) ◽  
pp. 7579-7584 ◽  
Author(s):  
Jeonghyeon Yang ◽  
Takashi Ichii ◽  
Kuniaki Murase ◽  
Hiroyuki Sugimura

2020 ◽  
Vol 20 (6) ◽  
pp. 3356-3360
Author(s):  
Hao Yong Yin ◽  
Yi Fan Zheng ◽  
Ling Wang

We report the formation of gold nanoparticles on indium tin oxide conducting glass (ITO) surface via electrodeposition method at room temperature. The prepared nano-Au electrodes has been fabricated for sensitive detection of Pb2+, and showed highly selective response toward Pb2+. The electrochemical detection of Pb2+ were determined by differential pulse stripping voltammetric (DPSV). The nano-Au electrochemical sensor could detect Pb2+ from 0.5 to 10 μM with detection limits of 0.06 μM (S/N= 3) and sensitivity of 0.27996 mA μM−1. The proposed sensor is simple, reliable, sensitive, selective, and low-cost, thus holds potential for practical application in Pb2+ detection.


2020 ◽  
Vol 3 (1) ◽  
pp. 51-58 ◽  
Author(s):  
Robi S. Datta ◽  
Nitu Syed ◽  
Ali Zavabeti ◽  
Azmira Jannat ◽  
Md Mohiuddin ◽  
...  

Nanoscale ◽  
2020 ◽  
Vol 12 (48) ◽  
pp. 24357-24361
Author(s):  
Bingbing Han ◽  
Sila Jin ◽  
Qi Chu ◽  
Yang Jin ◽  
Xiangxin Xue ◽  
...  

The localized surface plasmon resonance (LSPR) of Ag/indium tin oxide (ITO)@polystyrene (PS) in the visible-NIR region was dependent on the tuning of the carrier density caused by adjusting the thickness of the ITO layer.


2019 ◽  
Vol 9 (2) ◽  
pp. 326 ◽  
Author(s):  
Somasekhar Chinnadayyala ◽  
Jinsoo Park ◽  
Yonghyun Choi ◽  
Jae-Hee Han ◽  
Ajay Yagati ◽  
...  

The improved binding ability of graphene–nanoparticle composites to proteins or molecules can be utilized to develop new cell-based assays. In this study, we fabricated reduced graphene oxide–gold nanoparticles (rGO-AuNP) electrodeposited onto a transparent indium tin oxide (ITO) electrode and investigated the feasibility of the electrochemical impedance monitoring of cell growth. The electrodeposition of rGO–AuNP on the ITO was optically and electrochemically characterized in comparison to bare, rGO-, and AuNP-deposited electrodes. The cell growth on the rGO–AuNP/ITO electrode was analyzed via electrochemical impedance measurement together with the microscopic observation of HEK293 cells transfected with a green fluorescent protein expression vector. The results showed that rGO–AuNP was biocompatible and induced an increase in cell adherence to the electrode when compared to the bare, AuNP-, or rGO-deposited ITO electrode. At 54 h cultivation, the average and standard deviation of the saturated normalized impedance magnitude of the rGO–AuNP/ITO electrode was 3.44 ± 0.16, while the value of the bare, AuNP-, and rGO-deposited ITO electrode was 2.48 ± 0.15, 2.61 ± 0.18, and 3.01 ± 0.25, respectively. The higher saturated value of the cell impedance indicates that the impedimetric cell-based assay has a broader measurement range. Thus, the rGO–AuNP/ITO electrode can be utilized for label-free and real-time impedimetric cell-based assays with wider dynamic range.


Sign in / Sign up

Export Citation Format

Share Document