scholarly journals Rhodamine-Sulphuric Acid -A New Visualization Reagent for the Determination of Sucralose by HPTLC

2010 ◽  
Vol 7 (s1) ◽  
pp. S559-S565 ◽  
Author(s):  
Mohd Idris ◽  
Seema Srivastava ◽  
T. R. Baggi ◽  
S. K. Shulka ◽  
A. K. Ganjoo

Sucralose a UV-visible inactive compound was separated on silica gel plate without any plate treatment prior to analysis, derivatized with rhodamine - sulphuric acid reagent and detected densitometrically at 456 nm as olive green band. With this reagent sucralose also shows golden yellow fluorescence at 366 nm. Two new solvent systemsi.e. chloroform: methanol: toluene (v/v 5:3.5:1.5) (solvent system-I) and chloroform: ethanol: benzene (v/v 5:3:2) (solvent system-II) were developed and giving Rfvalues of 0.62 and 0.45 respectively. The method was found to be sensitive with good limit of detection (LOD) for two solvent systems. The method imparts specificity to the method as at 456 nm sucralose only gives olive green color spots where as other artificial sweeteners did not show any response to this reagent, where as carbohydrates gives black color spots. Similarly sucralose gives golden yellow fluorescence at 366 nm which is not given by any other artificial sweetener. The method was highly reproducible with relative standard deviation (RSD)≤3% (n=3) and was applied for the determination of sucralose in different matrices like cola drinks, lemon juices, sugar free sweets, tabletop sweeteners etc.etc.

2014 ◽  
Vol 21 (1) ◽  
pp. 11-15
Author(s):  
Daiva Kazlauskienė ◽  
Guoda Kiliuvienė ◽  
Palma Nenortienė ◽  
Giedrė Kasparavičienė ◽  
Ieva Matukaitytė

By conducting the toxicological analysis it is meaningful to determine the analytical system that could identify simultaneously several medicinal preparations quickly and precisely. The purpose of this work was to create and validate the method of thin-layer chromatography that would be suitable to separate the components of antidepressant mixture (amitriptyline hydrochloride, paroxetine hydrochloride, sertraline hydrochloride, fluvoxamine maleate and buspirone hydrochloride) and to identify them. The system was validated with regard to the sensitivity, repetition of data, resistance and particularity. The solvent systems with potential of high separation of components in their mixture were created: acetonitrile, methanol, ammonia solution 25 percent (85:10:5); acetonitrile, methanol, ammonia solution 25 percent (75:20:5); dichlormethane, 1,4-dioxane, ammonia solution 25 percent (50:45:5); dichlormethane, 1,4-dioxane, ammonia solution 25 percent (42:55:3); trichlormethane, 1,4-dioxane, ammonia solution 25 percent (25:70:5); trichlormethane, 1,4-dioxane, ammonia solution 25 percent (60:36:4). One of the most suitable solvent systems for separation of the analyzed mixture (sertraline, amitriptyline, paroxetine, buspirone, fluvoxamine) was determined – acetonitrile, methanol, ammonia solution 25 percent (85:10:5). When this solvent system was used, the average Rf values of the analyzed compounds differed the most. Validation was conducted – the relative standard deviation (RSD, percent) of the average Rf value of the analyzed compounds varied from 0,6 to 1,8 percent and did not exceed the permissible error of 5 percent. The sensitivity of methodology was determined by assessing the intensity of the mixture’s spots on the chromatographic plate. The detection limit of buspirone was 0,0012 µg; sertraline – 0,0008 µg; amitriptyline – 0,0004 µg; fluvoxamine – 0,0004 µg; paroxetine – 0,0008 µg. The resistance of results to the changed conditions – it was determined that when the amounts of the solvents acetonitrile and methanol were increased or decreased to two milliliters, the average Rf values of the analyzed compounds did not change statistically significantly


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Indhu Priya Mabbu ◽  
G. Sumathi ◽  
N. Devanna

Abstract Background The aim of the present method is to develop and validate a specific, sensitive, precise, and accurate liquid chromatography-mass spectrometry (LC-MS) method for the estimation of the phenyl vinyl sulfone in the eletriptan hydrobromide. The effective separation of the phenyl vinyl sulfone was achieved by the Symmetry C18 (50 × 4.6 mm, 3.5 μm) column and a mobile phase composition of 0.1%v/v ammonia buffer to methanol (5:95 v/v), using 0.45 ml/min flow rate and 20 μl of injection volume, with methanol used as diluent. The phenyl vinyl sulfone was monitored on atomic pressure chemical ionization mode mass spectrometer with positive polarity mode. Results The retention time of phenyl vinyl sulfone was found at 2.13 min. The limit of detection (LOD) and limit of quantification (LOQ) were observed at 1.43 ppm and 4.77 ppm concentration respectively; the linear range was found in the concentration ranges from 4.77 to 27.00 ppm with regression coefficient of 0.9990 and accuracy in the range of 97.50–102.10%. The percentage relative standard deviation (% RSD) for six replicates said to be injections were less than 10%. Conclusion The proposed method was validated successfully as per ICH guidelines. Hence, this is employed for the determination of phenyl vinyl sulfone in the eletriptan hydrobromide.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Vaibhav S. Adhao ◽  
Suraj R. Chaudhari ◽  
Jaya P. Ambhore ◽  
Sunil Sangolkar ◽  
Raju R. Thenge ◽  
...  

Abstract Background Human immunodeficiency virus (HIV) causes severe life-threatening condition, i.e., AIDS. HIV destabilises an individual’s ability to prevent infection. Therefore, the combine medication lamivudine (LVD) and tenofovir disoproxil fumarate (TDF) are prescribed to suppress the amount of HIV infection in individual’s body; thus, the individual’s immune system could function properly. Consequently, the objective of present research work was to investigate robust and sensitive liquid chromatography avenue for simultaneous determination of lamivudine and tenofovir disoproxil fumarate in pure material and combined dosage form. Results The reversed-phase chromatographic separation has been performed through Hypersil BDS C18 column using solvent system composed of 10 mM potassium dihydrogen phosphate (pH 4.0): acetonitrile (60:40% v/v). The determination was executed at 30 oC at 1 mL/min rate for flow of solvent system through column. The eluents of column were monitored at 265 nm using Photodiode Array detector has revealed admirable retention times, i.e., 4.67 and 8.78 min for both drugs, respectively. The calibration curve demonstrated excellent linearity in the range of 10–50 μg/mL for lamivudine and tenofovir disoproxil fumarate with better determination coefficients was more than (r2 0.999). Conclusion The estimable method was effectively validated with respect to accuracy, precision, sensitive (limit of detection and limit of quantitation), robustness, ruggedness, and for selectivity and specificity. The value less than 2 for percentage relative standard deviation for accuracy, precision, robustness, and ruggedness satisfying the acceptance criteria as per procedure of International Council for Harmonization of Technical Requirements for Pharmaceuticals for Human Use.


2010 ◽  
Vol 8 (3) ◽  
pp. 617-625 ◽  
Author(s):  
Hossein Abdolmohammad-Zadeh ◽  
Elnaz Ebrahimzadeh

AbstractA rapid dispersive liquid-liquid micro-extraction (DLLME) methodology based on the application of 1-hexylpyridinium hexafluorophosphate [C6py][PF6] ionic liquid (IL) as an extractant solvent was applied for the pre-concentration of trace levels of cobalt prior to determination by flame atomic absorption spectrometry (FAAS). 1-Phenyl-3-methyl-4-benzoyl-5-pyrazolone (PMBP) was employed as a chelator forming a Co-PMBP complex to extract cobalt ions from aqueous solution into the fine droplets of [C6py][PF6]. Some effective factors that influence the micro-extraction efficiency include the pH, the PMBP concentration, the amount of ionic liquid, the ionic strength, the temperature and the centrifugation time which were investigated and optimized. In the optimum experimental conditions, the limit of detection (3s) and the enrichment factor were 0.70 µg L−1 and 60, respectively. The relative standard deviation (RSD) for six replicate determinations of 50 µg L−1 Co was 2.36%. The calibration graph using the pre-concentration system was linear at levels 2–166 µg L−1 with a correlation coefficient of 0.9982. The applicability of the proposed method was evaluated by the determination of trace amounts of cobalt in several water samples.


2013 ◽  
Vol 634-638 ◽  
pp. 1586-1590
Author(s):  
Su Fang Wang ◽  
Shou Jie Zhang ◽  
Chun Hong Dong ◽  
Guo Qing Wang ◽  
Jun Feng Guo ◽  
...  

A method for simultaneous determination of residuals of four herbicides and pesticides, simazine, carboxin, diflubenzuron and rotenone, in Chinese green tea was developed. In the proposed method, the tea powder was placed in a centrifuge tube with a plug, extracted in saturated aqueous sodium chloride solution and acetonitrile, agitated using vortex oscillator, and then centrifuged 5 min at 4000 rpm. The supernatant solution was purified by primary secondary amine (PSA) sorbent, C18 power, and graphitized carbon black powder, respectively. Then the purified extracts were dissolved with acetonitrile:0.1% formic acid aqueous solution (40:60, V/V) and agitated, filtered using a syringe with 0.22 μm nylon filter prior to UPLC-MS/MS analysis. The UPLC analysis was performed on an ACQUITY UPLC® HSS T3 column (2.1 mm×100 mm, 1.8 µm), using acetonitrile-0.1% formic acid as mobile phase with the flow rate as 0.3 mL•min-1. Injection volume was 10 µL. Positive ionization mode was applied, and the ions were monitored in the multiple reaction monitoring (MRM) mode with curtain gas 0.069 MPa, collision gas 0.052 MPa, ESI ion spray voltage 5000 V, temperature 550 °C, nebulizer gas 0.24 MPa, and turbo gas 0.28 MPa. The limit of detection (LOD) and limit of quantitation (LOQ) of the proposed method are 1 μg•kg-1and 5 μg•kg-1, respectively. The average recoveries of the four pesticides at 10, 20, and 50 µg•kg-1spiking levels range from 77.4% to 95.3%. TheSupersSuperscript textcript textrelative standard deviation (RSD) (n=6) range form 11.83% to 4.52%.


Molecules ◽  
2021 ◽  
Vol 26 (7) ◽  
pp. 1837
Author(s):  
Harischandra Naik Rathod ◽  
Bheemanna Mallappa ◽  
Pallavi Malenahalli Sidramappa ◽  
Chandra Sekhara Reddy Vennapusa ◽  
Pavankumar Kamin ◽  
...  

A quick, sensitive, and reproducible analytical method for the determination of 77 multiclass pesticides and their metabolites in Capsicum and tomato by gas and liquid chromatography tandem mass spectrometry was standardized and validated. The limit of detection of 0.19 to 10.91 and limit of quantification of 0.63 to 36.34 µg·kg−1 for Capsicum and 0.10 to 9.55 µg·kg−1 (LOD) and 0.35 to 33.43 µg·kg−1 (LOQ) for tomato. The method involves extraction of sample with acetonitrile, purification by dispersive solid phase extraction using primary secondary amine and graphitized carbon black. The recoveries of all pesticides were in the range of 75 to 110% with a relative standard deviation of less than 20%. Similarly, the method precision was evaluated interms of repeatability (RSDr) and reproducibility (RSDwR) by spiking of mixed pesticides standards at 100 µg·kg−1 recorded anRSD of less than 20%. The matrix effect was acceptable and no significant variation was observed in both the matrices except for few pesticides. The estimated measurement uncertainty found acceptable for all the pesticides. This method found suitable for analysis of vegetable samples drawn from market and farm gates.


2010 ◽  
Vol 7 (4) ◽  
pp. 1612-1620 ◽  
Author(s):  
M. Keyvanfard ◽  
N. Abedi

A new, simple, sensitive and selective kinetic spectrophotometric method was developed for the determination of ultra trace amounts of vanadium(V). The method is based on the catalytic effect of vanadium(V) on the oxidation of malachite green oxalate (MG) by bromate in acidic and micellar medium. The reaction was monitored spectrophotometrically by measuring the decrease in the absorbance of malachite green oxalate (MG) at 625 nm with a fixed-time method. The decrease in the absorbance of MG is proportional to the concentration of vanadium(V) in the range of 1-100 ng/mL with a fixed time of 0.5-2 min from the initiation of the reaction. The limit of detection is 0.71 ng/mL of vanadium(V). The relative standard deviation for the determination of 5, 30, 50 ng/mL of vanadium(V) was2.5% 2.6%, 2.4% and respectively. The method was applied to the determination of vanadium(V) in water samples.


2013 ◽  
Vol 2013 ◽  
pp. 1-5
Author(s):  
Mohsen Keyvanfard ◽  
Khadijeh Alizad ◽  
Razieh Shakeri

A new kinetic spectrophotometric method is described for the determination of ultratrace amounts of sodium cromoglycate (SCG). The method based on catalytic action of SCG on the oxidation of amaranth with periodate in acidic and micellar medium. The reaction was monitored spectrophotometrically by measuring the decrease in absorbance of the amaranth at 518 nm, for the first 4 min from initiation of the reaction. Calibration curve was linear in the range of 4.0−36.0 ng mL−1SCG. The limit of detection is 2.7 ng mL−1SCG. The relative standard deviation (RSD) for ten replicate analyses of 12, 20, and 28 ng mL−1SCG was 0.40%, 0.32%, and 0.53%, respectively. The proposed method was used for the determination of SCG in biological samples.


2017 ◽  
Vol 9 (2) ◽  
pp. 34
Author(s):  
N. Balaji ◽  
Sayeeda Sultana

Objective: An efficient, high performance liquid chromatographic method has been developed and validated for the quantification of related substances in pioglitazone hydrochloride drug substance.Methods: This method includes the determination of three related substances in pioglitazone hydrochloride. The mobile phase A is 0.1% w/v triethylamine in water with pH 2.5 adjusted by dilute phosphoric acid. The mobile phase B is premixed and degassed mixtures of acetonitrile and methanol. The flow rate was 1 ml/min. The elution used was gradient mode. The HPLC column used for the analysis was symmetry C18 with a length of 250 mm, the internal diameter of 4.6 mm and particle size of 5.0 microns.Results: The developed method was found to be linear with the range of 0.006-250% with a coefficient of correlation 0.99. The precision study revealed that the percentage relative standard deviation was within the acceptable limit. The limit of detection and limit of quantitation of the impurities was less than 0.002%and 0.006% with respect to pioglitazone hydrochloride test concentration of 2000 µg/ml respectively. This method has been validated as per ICH guidelines Q2 (R1).Conclusion: A reliable, economical HPLC method was magnificently established for quantitative analysis of related substances of pioglitazone hydrochloride drug substance.


2003 ◽  
Vol 68 (8-9) ◽  
pp. 691-698 ◽  
Author(s):  
Milena Jelikic-Stankov ◽  
Predrag Djurdjevic ◽  
Dejan Stankov

In this work a new enzymatic method for the determination of uric acid in human serum has been developed. The method is based on the oxidative coupling reaction between the N-methyl-N-(4-aminophenyl)-3-methoxyaniline (NCP) reagent and the hydrogen ? donor reagent N-ethyl-N-(2-hydroxy-3-sulfopropyl)-3-methylaniline (TOOS), in the system involving three enzymes: uricase, peroxidase and ascorbate oxidase. Using this method uric acid could be determined in concentrations up to 1.428 mmol/L, with a relative standard deviation of up to 1.8 %. The effect of the medium pH and the NCP concentration on the linearity of the chromogen absorbance versus the uric acid concentration curve was investigated. The influence of the uricase activity on the maximum rate of uric acid oxidation was also examined. The use of the NCP reagent demonstrated a more precise and more sensitive determination of the uric acid compared to the determination with 4-aminoantipyrine (4-AA) as the coupling regent. The sensitivity of the method determined from the calibration curve was 0.71 absorbance units per mmol/L of uric acid; the limit of detection was LOD = 0.0035 mmol/L and the limit of quantification was LOQ = 0.015 mmol/L of uric acid.


Sign in / Sign up

Export Citation Format