scholarly journals Simulation of Electron Energy Spectra of a Biased Paracentric Hemispherical Deflection Analyzer as a Function of Entry Bias: Effects of Misalignments

2014 ◽  
Vol 2014 ◽  
pp. 1-8 ◽  
Author(s):  
O. Sise

The performance of a biased paracentric hemispherical deflection analyzer (HDA), including fringing fields and their effect on focusing and energy resolution, is investigated using numerical methods. Electron energy spectra are calculated for three entry positionsR0=84 mm, 100 mm, and 112 mm and compared with the recent experimental measurements. In both experiment and calculation, the two different paracentric entry positionsR0=84 mm andR0=112 mm, on either side of the mean radius of 100 mm, are found to have a base energy resolution of about two times better than the conventional centric entry positionR0=100 mm. In order to explain the discrepancies (6–30%) between the simulated and the experimental resolutions the focusing characteristics are further investigated for different displacements of the input lens (ΔR0) with respect to the entry positionR0and the tilted input beam axis byαshiftin the dispersive direction. We have found that the blame does not in fact lie with the theory and we have shown that the input lens may have been misaligned in the experiment. Slight misalignments affect both the true energy resolution measurement and the transmission of the beam.

2001 ◽  
Vol 7 (S2) ◽  
pp. 908-909
Author(s):  
H.A. Brink ◽  
M. Barfels ◽  
B. Edwards ◽  
P. Burgner

A new type of electron energy loss spectrometer for use with monochromated microscopes is presented. The energy resolution of the spectrometer is better than 0.100 eV. A completely new electron optical design with a number of extra optical elements and advanced tuning software makes it possible to correct spectrum aberrations to 4th order, which increases sensitivity and collection angles. New high-stability electronics make it possible to maintain energy resolution over a period of several minutes in a practical laboratory environment.The energy resolution of Transmission Electron Microscopes (TEMs) equipped with electron energy loss spectrometers is determined by a combination of the energy spread of the electron source, the stability of the microscope’s high voltage power supply, and the energy resolution of the spectrometer. Commercial microscopes usually employ electron sources with an energy distributions of around 0.5 eV or more (FWHM), limiting the energy ultimate energy resolution that can be achieved. Recently FEI constructed a special 200 kV TEM with a built-in monochromator which makes it possible to monochromize the electron source to better than 0.100 eV. A prototype of the presented spectrometer has been installed on this microscope.


Author(s):  
Eckhard Quandt ◽  
Stephan laBarré ◽  
Andreas Hartmann ◽  
Heinz Niedrig

Due to the development of semiconductor detectors with high spatial resolution -- e.g. charge coupled devices (CCDs) or photodiode arrays (PDAs) -- the parallel detection of electron energy loss spectra (EELS) has become an important alternative to serial registration. Using parallel detection for recording of energy spectroscopic large angle convergent beam patterns (LACBPs) special selected scattering vectors and small detection apertures lead to very low intensities. Therefore the very sensitive direct irradiation of a cooled linear PDA instead of the common combination of scintillator, fibre optic, and semiconductor has been investigated. In order to obtain a sufficient energy resolution the spectra are optionally magnified by a quadrupole-lens system.The detector used is a Hamamatsu S2304-512Q linear PDA with 512 diodes and removed quartz-glas window. The sensor size is 13 μm ∗ 2.5 mm with an element spacing of 25 μm. Along with the dispersion of 3.5 μm/eV at 40 keV the maximum energy resolution is limited to about 7 eV, so that a magnification system should be attached for experiments requiring a better resolution.


2014 ◽  
Vol 14 (1) ◽  
pp. 81-87
Author(s):  
Maciej Rachwał ◽  
Justyna Drzał-Grabiec ◽  
Katarzyna Walicka-Cupryś ◽  
Aleksandra Truszczyńska

Abstract Background: The post-mastectomy changes to the locomotor system are related to the scar and adhesion or to the lymphatic edema after amputation which, in turn, lead to local and global distraction of the work of the muscles. These changes lead to body statics disturbance that changes the projection of the center of gravity and worsens motor response due to changing of the muscle sensitivity. Objective: The aim of the study was to evaluate the static balance of women after undergoing mastectomy. Methods: The study included 150 women, including 75 who underwent mastectomy (mean age: 60±7.6) years, mean body mass index (BMI): 26 (±3.6) kg/m2) and 75 who were placed in the control group with matched age and BMI. The study was conducted using a tensometric platform. Results: Statistically significant differences were found for almost all parameters between the post-mastectomy group and group of healthy women, regarding center of foot pressure (COP) path length in the Y and X axes and the mean amplitude of COP. Conclusions: First, the findings revealed that balance in post-mastectomy women is significantly better than in the control group. Second, physiotherapeutic treatment of post-mastectomy women may have improved their posture stability compared with their peers.


2019 ◽  
Vol 219 ◽  
pp. 08003
Author(s):  
Maja Verstraeten

The SoLid Collaboration is currently operating a 1.6 ton neutrino detector near the Belgian BR2 reactor. Its main goal is the observation of the oscillation of electron antineutrinos to previously undetected flavour states. The highly segmented SoLid detector employs a compound scintillation technology based on PVT scintillator in combination with LiF-ZnS(Ag) screens containing the 6Li isotope. The experiment has demonstrated a channel-to-channel response that can be controlled to the level of a few percent, an energy resolution of better than 14% at 1 MeV, and a determination of the interaction vertex with a precision of 5 cm. This contribution highlights the major outcomes of the R&D program, the quality control during component manufacture and integration, the current performance and stability of the full-scale system, as well as the in-situ calibration of the detector with various radioactive sources.


2016 ◽  
Vol 8 (8) ◽  
pp. 182
Author(s):  
Kanwar Priyanaka ◽  
Y. C. Gupta ◽  
S. R. Dhiman ◽  
R. K. Dogra ◽  
Sharma Madhu ◽  
...  

<p>The studies on heterosis were carried with four male sterile lines namely; ms<sub>7</sub>, ms<sub>8</sub>, ms<sub>9,</sub> ms<sub>10</sub> and 18 diverse pollinators as tester by using line × tester crossing programme. The 72 F<sub>1</sub> hybrids were produced and evaluated along with 22 parental lines during summer 2009 and rainy season 2009 in Randomized Block Design. Observations were recorded on nine quantitative traits during both the seasons. Highly significant variances for all the traits indicated the sufficient variability in the parental material for all the characters under study. The performance of F<sub>1</sub> hybrids was much better than the mean performance of parents during both the crop seasons. Appreciable heterosis was observed in all the characters, except flower weight in summer and plant height in rainy season.</p>


2021 ◽  
Author(s):  
Habtamu W. Tesfaw ◽  
Ilkka I. Virtanen ◽  
Anita T. Aikio ◽  
Amore' Elsje Nel ◽  
Michael Kosch ◽  
...  

Author(s):  
Mingwen Yang ◽  
Zhiqiang (Eric) Zheng ◽  
Vijay Mookerjee

Online reputation has become a key marketing-mix variable in the digital economy. Our study helps managers decide on the effort they should use to manage online reputation. We consider an online reputation race in which it is important not just to manage the absolute reputation, but also the relative rating. That is, to stay ahead, a firm should try to have ratings that are better than those of its competitors. Our findings are particularly significant for platform owners (such as Expedia or Yelp) to strategically grow their base of participating firms: growing the middle of the market (firms with average ratings) is the best option considering the goals of the platform and the other stakeholders, namely incumbents and consumers. For firms, we find that they should increase their effort when the mean market rating increases. Another key insight for firms is that, sometimes, adversity can come disguised as an opportunity. When an adverse event strikes the industry (such as a reduction in sales margin or an increase in the cost of effort), a firm’s profit can increase if it can manage this event better than its competitors.


Author(s):  
Timothy Marchok

AbstractMultiple configurations of the Geophysical Fluid Dynamics Laboratory vortex tracker are tested to determine a setup that produces the best representation of a model forecast tropical cyclone center fix for the purpose of providing track guidance with the highest degree of accuracy and availability. Details of the tracking algorithms are provided, including descriptions of both the Barnes analysis used for center-fixing most variables and a separate scheme used for center-fixing wind circulation. The tracker is tested by running multiple configurations on all storms from the 2015-2017 hurricane seasons in the Atlantic and eastern Pacific Basins using forecasts from two operational National Weather Service models, the Global Forecast System (GFS) and the Hurricane Weather Research and Forecast (HWRF) model. A configuration that tracks only 850 mb geopotential height has the smallest forecast track errors of any configuration based on an individual parameter. However, a configuration composed of the mean of eleven parameters outperforms any of the configurations that are based on individual parameters. Configurations composed of subsets of the eleven parameters and including both mass and momentum variables provide results comparable to or better than the full 11-parameter configuration. In particular, a subset configuration with thickness variables excluded generally outperforms the 11-parameter mean, while one composed of variables from only the 850 mb and near-surface layers performs nearly as well as the 11-parameter mean. Tracker configurations composed of multiple variables are more reliable in providing guidance through the end of a forecast period than are tracker configurations based on individual parameters.


2018 ◽  
Vol 10 (12) ◽  
pp. 4863 ◽  
Author(s):  
Chao Huang ◽  
Longpeng Cao ◽  
Nanxin Peng ◽  
Sijia Li ◽  
Jing Zhang ◽  
...  

Photovoltaic (PV) modules convert renewable and sustainable solar energy into electricity. However, the uncertainty of PV power production brings challenges for the grid operation. To facilitate the management and scheduling of PV power plants, forecasting is an essential technique. In this paper, a robust multilayer perception (MLP) neural network was developed for day-ahead forecasting of hourly PV power. A generic MLP is usually trained by minimizing the mean squared loss. The mean squared error is sensitive to a few particularly large errors that can lead to a poor estimator. To tackle the problem, the pseudo-Huber loss function, which combines the best properties of squared loss and absolute loss, was adopted in this paper. The effectiveness and efficiency of the proposed method was verified by benchmarking against a generic MLP network with real PV data. Numerical experiments illustrated that the proposed method performed better than the generic MLP network in terms of root mean squared error (RMSE) and mean absolute error (MAE).


1985 ◽  
Vol 59 (2) ◽  
pp. 592-596 ◽  
Author(s):  
J. C. Collins ◽  
J. H. Newman ◽  
N. E. Wickersham ◽  
W. K. Vaughn ◽  
J. R. Snapper ◽  
...  

Our purpose was to see if the postmortem weight ratio of extravascular lung water to blood-free dry lung (blood-free ratio) was related to similar ratios in blood-inclusive lung and in blood. We developed linear regressions of blood-free ratio on ratios for blood-inclusive lung and blood together and for blood-inclusive lung alone for 73 sheep studied under 11 different protocols and for two subgroups of sheep, one with plasma space expansion and the other without expansion. The relation of ratios of blood-free to blood-inclusive lungs was different between the two subgroups. Although all regressions were highly correlated, the fits of the blood-free ratio on ratios for blood-inclusive lung and blood together were better than for blood-inclusive lung alone. The mean error of prediction of extravascular lung water for all sheep was significantly less for the regression of blood-free ratio on ratios for blood and blood-inclusive lung together (11 g) than for blood-inclusive lung alone (18 g). This study shows that weights of lung homogenate and blood samples before and after simple oven drying can be used to provide accurate inexpensive estimates of postmortem extravascular lung water.


Sign in / Sign up

Export Citation Format

Share Document