scholarly journals Thermal Insulating Concrete Wall Panel Design for Sustainable Built Environment

2014 ◽  
Vol 2014 ◽  
pp. 1-12 ◽  
Author(s):  
Ao Zhou ◽  
Kwun-Wah Wong ◽  
Denvid Lau

Air-conditioning system plays a significant role in providing users a thermally comfortable indoor environment, which is a necessity in modern buildings. In order to save the vast energy consumed by air-conditioning system, the building envelopes in envelope-load dominated buildings should be well designed such that the unwanted heat gain and loss with environment can be minimized. In this paper, a new design of concrete wall panel that enhances thermal insulation of buildings by adding a gypsum layer inside concrete is presented. Experiments have been conducted for monitoring the temperature variation in both proposed sandwich wall panel and conventional concrete wall panel under a heat radiation source. For further understanding the thermal effect of such sandwich wall panel design from building scale, two three-story building models adopting different wall panel designs are constructed for evaluating the temperature distribution of entire buildings using finite element method. Both the experimental and simulation results have shown that the gypsum layer improves the thermal insulation performance by retarding the heat transfer across the building envelopes.

2013 ◽  
Vol 594-595 ◽  
pp. 1020-1024 ◽  
Author(s):  
Mohd Faiz Md Fudzee ◽  
Nor Hayati Hamid

In this paper, the seismic performance of the insulated sandwich wall panel is studied. Two samples W1 and W2 of Insulated Sandwich Wall Panel (ISWP) were tested under in-plane lateral cyclic loading. The difference between W1 and W2 is the numbers of wall plug used in order to hold the specimen in standing parallel position. Four wall plugs used for W1 meanwhile eleven wall plugs used for W2. ISWP is placed axially on top of the foundation beam. The concrete block is slotted on top of the wall panel as load transfer from the roof. The aspect ratio of the specimen is Ar = H/B = 1.97 and slenderness ratio is λ = H/t = 36.92. The testing is conducted with small percent of drift which is 0.1% and continued with 0.2%. The drift was increased gradually about 0.2% until reach ±1.0%. Furthermore, the specimen was tested with an increment of ±0.2% drift until the specimens reach the strength capacity. The experimental results showed that for the first specimen, the wall panel behaves elastically up to 0.4% drift before yielding. Due to loading and unloading condition, the aluminium frame that used along the perimeter of the wall panel buckled at 1.2% drift. For the second specimen the wall panel behaves elastically up to 0.4% drift before yielding. Once 0.6% drift applied, crack started to appear at the connection joint between G.I channel and foundation beam. The analysis of the result from the graphs of hysteresis loop for both W1 and W2 were presented by considering the seismic parameter such as stiffness, ductility and equivalent viscous damping.


2021 ◽  
Vol 11 (6) ◽  
pp. 2688
Author(s):  
Shaochun Ma ◽  
Lianghui Li ◽  
Peng Bao

The research objective of this study was the seismic performance of double-row reinforced ceramsite concrete sandwich wall panels. The feasibility of upgrading a new wall panel from a non-load-bearing partition wall to a load-bearing seismic wall was examined by conducting cyclic load tests on five wall panel specimens. The test piece was a sandwich thermal insulation structure that could achieve a good protection distance between the thermal insulation material and the fire source so that the fire prevention problem could be solved. At the same time, the problem of easy fall-off of the insulation system was also solved. The specimens were divided into three groups, including three double-row reinforced ceramsite concrete sandwich wall panels with different dosages of alkali-resistant glass fiber, a double-row reinforced ordinary concrete sandwich wall panel, and a solid concrete ceramic wallboard. The effects of different dosages of alkali-resistant glass fiber, construction forms, and bearing side plate materials on the seismic performance of the sandwich wall panels were investigated separately for the specimens. From the analysis of the specimen results (damage characteristics, hysteresis curves, energy dissipation capacity, bearing capacity, ductility, longitudinal reinforcement strain, and stiffness degradation), it could be seen that among the five types of wallboard, the double-row reinforced ceramsite concrete sandwich wall panel with 0.3% fiber content had the best ductility and energy dissipation capacity. Adding fiber could solve or improve the problem of the low ultimate bearing capacity of ceramsite concrete as the wallboard’s bearing material. Compared with the same size solid ordinary concrete wallboard, the bearing capacity of the double-row reinforced ceramic concrete sandwich panel was slightly reduced. However, the additional seismic performance indexes were relatively superior. Through the analysis of the test results, it was shown that, when considering the thermal performance and seismic capacity, the new wall panel had good prospects for engineering applications.


2022 ◽  
Author(s):  
Feng Xiong ◽  
Wen Chen ◽  
Qi Ge ◽  
Jiang Chen ◽  
Yang Lu

Abstract A novel low-rise bolt - assembled precast concrete sandwich wall panel structure for rural residential houses was proposed, in which the connections between wall and wall, and wall and floor were connected by high strength bolts and steel plates. The bolt joints can be easily installed and disassembled. They are replaceable to make the precast structure demountable and reassembled. All the components are connected together by the novel bolted connectors. This paper presents the shake-table tests of a full-scale two-story bolt-assembled precast concrete sandwich wall building. The results indicated that the proposed structural system had good seismic performance and remained in the elastic stage with no damage after 9-degree rare earthquake excitation for the Model-1. The Model-2 exhibited excellent capacity and performed satisfactorily under the excitation up to 0.8 g. Cracks were observed at the wall openings and the base of walls and columns, which was similar to that of a cast-in-situ structure. The damage statuses were mainly light damage and moderate damage. The bolt connection joints were not anti-seismic weak places and had good seismic performance. Equivalent base shear method is suitable for estimating the seismic demand of the proposed precast concrete sandwich wall panel structure.