scholarly journals Seismic Isolation Performance Evaluation for a Class of Inerter-Based Low-Complexity Isolators

2020 ◽  
Vol 2020 ◽  
pp. 1-12
Author(s):  
Fei Cao ◽  
Michael Z. Q. Chen ◽  
Yinlong Hu

In this paper, the seismic base isolation problem for all low-complexity networks containing one inerter, one spring, and one damper is studied based on a multi-degree-of-freedom model. The analytical solutions for the H2 performance optimization are derived, and the traditional tuned mass damper (TMD) is employed for comparison. Extensive numerical simulations are performed to verify the effectiveness of the obtained results. The results show that for different seismic wave excitations, some isolators are better than TMD in controlling the displacement of the main structure. Moreover, with the increase of the TMD mass ratio, the isolation performances of the inerter-based isolators are increasingly better than that of TMD.


2021 ◽  
Author(s):  
◽  
Ivan Banović

The problem under consideration is the earthquake impact on structures. The subject of the performed research is the efficiency of seismic base isolation using layers of predominantly natural materials below the foundation, as well as the development of a numerical model for seismic analysis of structures with such isolation. The aseismic layers below foundation are made of limestone sand - ASL-1, stone pebbles - ASL-2, and stone pebbles combined with layers of geogrid and geomembrane - ASL-3. The experimental research methodology is based on the use of shake-table and other modern equipment for dynamic and static testing of structures. Experiments were conducted on the basis of detailed research plan and program. Efficiency of the limestone sand layer - ASL-1 was tested on cantilever concrete columns, under seismic excitations up to failure, varying the sand thickness and intensity of seismic excitation. Influence of several layer parameters on the efficiency of stone pebble layer - ASL-2 was investigated. For each considered layer parameter, a rigid model M0 was exposed to four different accelerograms, with three levels of peak ground acceleration (0.2 g, 0.4 g and 0.6 g), while all other layer parameters were kept constant. On the basis of test results, the optimal pebble layer was adopted. Afterwards, the optimal ASL-2 efficiency was tested on various model parameters: stiffness (deformable models M1-M4), foundation size (small and large), excitation type (four earthquake accelerograms), and stress level in the model (elastic and up to failure). In the ASL-3 composite aseismic layer, the optimal ASL-2 is combined with a thin additional layer of sliding material (geogrid, geomembrane above limestone sand layer), in order to achieve greater efficiency of this layer than that of the ASL-2. A total of eleven different aseismic layers were considered. To determine the optimal ASL-3, the M0 model was used, like for the ASL-2. On the basis of test results, the optimal ASL-3 layer was adopted (one higher strength geogrid at the pebble layer top). The optimal ASL-3 is tested on various model parameters, analogous to the optimal ASL-2. A numerical model for reliable seismic analysis of concrete, steel, and masonry structures with seismic base isolation using ASL-2 was developed, with innovative constitutive model for seismic isolation. The model can simulate the main nonlinear effects of mentioned materials, and was verified on performed experimental tests. In relation to the rigid base - RB without seismic isolation, model based on the ASL-1 had an average reduction in seismic force and strain/stress by approximately 10% at lower PGA levels and approximately 14% at model failure. Due to the effect of sand calcification over time, the long-term seismic efficiency of such a layer is questionable. It was concluded that the aseismic layers ASL-2 and ASL-3 are not suitable for models of medium-stiff structure M3 and soft structure M4. In relation to the RB without seismic isolation, the M1 (very stiff structure) and M2 (stiff structure) based on the ASL-2 had an average reduction in seismic force and strain/stress by approximately 13% at lower PGA levels and approximately 25% at model failure. In relation to the RB without seismic isolation, the M1 and M2 based on the ASL-3 had an average reduction in seismic force and strain/stress by approximately 25% at lower PGA levels and approximately 34% at model failure. In relation to the RB without seismic isolation, the ASL-2 and ASL-3 did not result in major M1 and M2 model displacements, which was also favourable. It is concluded that the ASL-2 and especially ASL-3 have great potential for seismic base isolation of very stiff and stiff structures, as well as small bridges based on solid ground, but further research is needed. In addition, it was concluded that the developed numerical model has great potential for practical application. Finally, further verification of the created numerical model on the results of other experimental tests is needed, but also improvement of the developed constitutive models.



2021 ◽  
pp. 875529302098196
Author(s):  
Tansu Gökçe ◽  
Engin Orakdöğen ◽  
Ercan Yüksel

A novel seismic base isolation system has been developed for high-voltage (HV) porcelain post insulators. The seismic isolation device consists of two steel plates, four polyurethane springs, and a steel rod, which are low-cost components compared to the post insulators. Two alternative designs of the device are experimentally and numerically assessed in this article. A simple and robust numerical model consisting of linear line elements and nonlinear springs was generated, and subsequently validated using the experimental results. Incremental dynamic analyses (IDAs) were then performed to obtain fragility curves. Ten historical earthquake profiles, scaled to intensities between 0.1 and 2.0 g, were then applied to the numerical models. The fragility curves, generated according to the latest version of IEEE-693, demonstrate that the seismic isolation devices are highly effective in diminishing the base moment of the porcelain insulator. It should be noted that relatively large displacements at the top of the pole must be accounted for by ensuring adequate slackness in the flexible conductors.



Author(s):  
Dario DE DOMENICO ◽  
Predaricka DEASTRA ◽  
Giuseppe RICCIARDI ◽  
Neil D. SIMS ◽  
David J. WAGG


Tuned mass dampers (TMD) are one of the most reliable devices to control the vibration of the structure. The optimum mass ratio required for a single tuned mass damper (STMD) is evaluated corresponding to the fundamental natural frequency of the structure. The effect of STMD and Multiple tuned mass dampers (MTMD) on a G+20 storey structure are studied to demonstrate the damper’s effectiveness in seismic application. The location and number of tuned mass dampers are studied to give best structural performance in maximum reduction of seismic response for El Centro earthquake data. The analysis results from SAP 2000 software tool shows damper weighing 2.5% of the total weight of the structure effectively reduce the response of the structure. Study shows that introduction of 4-MTMD at top storey can effectively reduce the response by 10% more in comparison to single tuned mass damper. The use of MTMD of same mass ratio that of STMD is more effective in seismic response.



Author(s):  
Satoshi Fujita ◽  
Keisuke Minagawa ◽  
Mitsuru Miyazaki ◽  
Go Tanaka ◽  
Toshio Omi ◽  
...  

This paper describes three-dimensional isolation performance of seismic isolation system using air bearings. Long period seismic waves having predominant period of from a few seconds to a few ten seconds have recently been observed in various earthquakes. Also resonances of high-rise buildings and sloshing of petroleum tanks in consequence of long period seismic waves have been reported. Therefore the isolation systems having very long natural period or no natural period are required. In a previous paper [1], we proposed an isolation system having no natural period by using air bearings. Additionally we have already reported an introduction of the system, and have investigated horizontal motion during earthquake in the previous paper. It was confirmed by horizontal vibration experiment and simulation in the previous paper that the proposed system had good performance of isolation. However vertical motion should be investigated, because vertical motion varies horizontal frictional force. Therefore this paper describes investigation regarding vertical motion of the proposed system by experiment. At first, a vertical excitation test of the system is carried out so as to investigate vertical dynamic property. Then a three-dimensional vibration test using seismic waves is carried out so as to investigate performance of isolation against three-dimensional seismic waves.



2019 ◽  
Vol 258 ◽  
pp. 05005 ◽  
Author(s):  
Wivia Octarena Nugroho ◽  
Dina Rubiana Widarda ◽  
Oryza Herdha Dwyana

As the need of the train speed increased, the existing bridges need to be evaluated, especially in dynamic responses, which are deformation and acceleration. In this study, Cisomang Bridge is modeled and analyzed due to the high-speed train SJ X2 in varying speeds, 50 km/h, 100 km/h, 150 km/h, and 200 km/h. The used of tuned mass damper also will be varied on its setting and placing. The tuned mass dampers setting be varied based on the first or second natural frequency and the placing of tuned mass damper be varied based on maximum deformation of the first or second mode. Moreover, the tuned mass damper ratio will be varied 1% and 1.6%. For all speed variations, dynamic responses of structure without TMD still fulfil the Indonesian Government Criterion based on PM 60 - 2012 but do not meet requirement of comfort criteria based on DIN-Fachbericht 101. Furthermore, only for the speed train 50km/h dynamic responses of structure fulfil safety criteria based on Eurocode EN 1990:2002, whereas the other speed variations do not meet that requirement. In the use of TMD 1% mass ratio, the structure fulfils the safety criteria for all speed variations. In the use of TMD 1.6% mass ratio, all the structure fulfils the safety and comfort criteria except 100 km/h speed which only fulfils the safety criteria.



Author(s):  
Simone Spagnol ◽  
Michele Geronazzo ◽  
Davide Rocchesso ◽  
Federico Avanzini

Purpose – The purpose of this paper is to present a system for customized binaural audio delivery based on the extraction of relevant features from a 2-D representation of the listener’s pinna. Design/methodology/approach – The most significant pinna contours are extracted by means of multi-flash imaging, and they provide values for the parameters of a structural head-related transfer function (HRTF) model. The HRTF model spatializes a given sound file according to the listener’s head orientation, tracked by sensor-equipped headphones, with respect to the virtual sound source. Findings – A preliminary localization test shows that the model is able to statically render the elevation of a virtual sound source better than non-individual HRTFs. Research limitations/implications – Results encourage a deeper analysis of the psychoacoustic impact that the individualized HRTF model has on perceived elevation of virtual sound sources. Practical implications – The model has low complexity and is suitable for implementation on mobile devices. The resulting hardware/software package will hopefully allow an easy and low-tech fruition of custom spatial audio to any user. Originality/value – The authors show that custom binaural audio can be successfully deployed without the need of cumbersome subjective measurements.



2012 ◽  
Vol 182-183 ◽  
pp. 2080-2084
Author(s):  
Jie Li ◽  
Xue Xiang Wang ◽  
Hao Liu

Auto white balance (AWB) is an important function of digital camera. The purpose of white balance is to adjust the image to make it look like taken under standard light conditions. We present a new technique to detect the reference white point of image in this paper. This technique detects the white point of image by using dynamic threshold method, thus making it more flexible and more applicable compared to other algorithms. We test 50 images which were taken under different light sources, and find that this algorithm is better than or comparable to other algorithms both in subjective and objective aspects. At the same time, this algorithm has low complexity, and it can be easily applied to hardware implementation.



2012 ◽  
Vol 446-449 ◽  
pp. 378-381
Author(s):  
Jian Min Jin ◽  
Ping Tan ◽  
Fu Lin Zhou ◽  
Yu Hong Ma ◽  
Chao Yong Shen

Mid-story isolation structure is developing from base isolation structures. As a complex structural system, the work mechanism of base isolation structure is not entirely appropriate for mid-story isolation structure, and the prolonging of structural natural period may not be able to decrease the seismic response of substructure and superstructure simultaneously. In this paper, for a four-story steel frame model, whose prototype first natural period is about 1s without seismic isolation design, the seismic responses and isolation effectiveness of mid-story isolation system with lead rubber bearing are studied experimentally by changing the location of isolation layer. Respectively, the locations of isolation layer are set at bottom of the first story, top of the first story, top of the second story and top of the third story. The results show that mid-story isolation can reduce seismic response in general, and substructure acceleration may be amplified.



Author(s):  
Kengo Goda ◽  
Osamu Furuya ◽  
Kohei Imamura ◽  
Kenta Ishihana

At the present, base isolation system has been recognized by general earthquake resistant technique since the Great Hanshin Earthquake 1995. The seismic isolation will be aggressively applied to not only architectural and civil structures but also various structures, because the effectiveness on seismic safety had been demonstrated again in the Great East Japan Earthquake. In generally, although the base isolation system is divided into laminated rubber bearing type and friction sliding bearing type. In the case of former type, shape factor, maximum or minimum outer shapes and so on are restricted by the material characteristics in visco-elastic material. In general, the isolation structure is used in high damping rubber. However, we pay attention to base isolation using urethane elastomer. Urethane elastomer has excellent elasticity, mechanical strength, abrasion resistance, weather resistance, oil resistance, impact resistance the absorbent, anti-vibration and excellent low-temperature properties. Furthermore, it is possible to impart various characteristics by a combination of isocyanate and polyol and chain extender, requires no large-scale apparatus, it has the advantage molecular design is easy. In previous study, the research and development of laminated type base isolation device using urethane elastomer was carried out to upgrade a seismic safety for various structures. The fundamental characteristics was investigated from several loading test by using various experimental devices, and the design formula for the stiffness and equivalent damping coefficient is formulated as an approximate expression of mechanical characteristics until now. It was confirmed that urethane elastomer is not hardening up to 500% shear strain. Moreover, the experimental examination for aged deterioration in the urethane material has been continuously carried out. As the results, it was confirmed that the laminated type seismic isolation device using urethane elastomer is possible to develop as a practicable device from the stable mechanical properties as considering in design step. In this study, the small-scale laminated type base isolation device using urethane elastomer is advanced to the direction of further technical upgrading and of scale down for light-weight structure as a sever rack. The first stage, basic properties of the urethane elastomer has been investigated by loading test. Furthermore, the design equation is created by loading test using urethane elastomer. The validity of the design equation has been confirmed. The second stage, the compression creep test with laminated type base isolation device has been investigated to confirm an effect on light-weight mechanical devices.



Sign in / Sign up

Export Citation Format

Share Document