scholarly journals Digital Rectal Examination Is a Valuable Bedside Tool for Detecting Dyssynergic Defecation: A Diagnostic Study and a Meta-Analysis

2021 ◽  
Vol 2021 ◽  
pp. 1-9
Author(s):  
Jie Liu ◽  
Chaolan Lv ◽  
Yizhou Huang ◽  
Ying Wang ◽  
Dandan Wu ◽  
...  

Background. Accurate dyssynergic defecation (DD) diagnosis depends on anorectal physiological tests that are not widely available. Aim. The purpose of this study is to evaluate the diagnostic yield of digital rectal examination (DRE) compared with anorectal physiological tests in diagnosing DD in patients with constipation. Methods. A total of 218 chronic constipation patients who fulfilled the Rome IV diagnostic criteria for functional constipation (FC) and underwent a standardized DRE and high-resolution anorectal manometry (HRAM) test were enrolled in this study. The diagnostic accuracy of DRE compared with HRAM was evaluated, and the agreement between DRE and HRAM was calculated. Furthermore, a comprehensive literature search on PubMed, Web of Science, Cochrane Library, and Embase database was conducted to further elucidate the pooled diagnostic accuracy of DRE in DD patients. Results. A total of 101 patients (46.33%) had a DD pattern using HRAM, while 117 patients (53.67%) were diagnosed without DD. The sensitivity of DRE in diagnosing dyssynergia was 71.3%, and the specificity was 76.1%. There was a moderate agreement between DRE and HRAM for diagnosing DD (κ-coefficient = 0.474, P < 0.001 ). Meanwhile, six studies (including our study) comprising 964 constipated patients were included in our meta-analysis. The outcomes demonstrated that the AUC was 0.85 (95% CI 0.82–0.88) with 77% summary sensitivity (95% CI 65–86) and 80% summary specificity (95% CI 71–86) to diagnose DD. Conclusions. DRE could be a valuable tool for screening DD. Our study revealed acceptable sensitivity and specificity of DRE in detecting dyssynergia compared with the physiological tests. Meanwhile, our study highlights that DRE remains an important tool in clinical practice.

2021 ◽  
Vol 11 (6) ◽  
pp. 568
Author(s):  
Óscar Rapado-González ◽  
Cristina Martínez-Reglero ◽  
Ángel Salgado-Barreira ◽  
Laura Muinelo-Romay ◽  
Juan Muinelo-Lorenzo ◽  
...  

DNA hypermethylation is an important epigenetic mechanism for gene expression inactivation in head and neck cancer (HNC). Saliva has emerged as a novel liquid biopsy representing a potential source of biomarkers. We performed a comprehensive meta-analysis to evaluate the overall diagnostic accuracy of salivary DNA methylation for detecting HNC. PubMed EMBASE, Web of Science, LILACS, and the Cochrane Library were searched. Study quality was assessed by the Quality Assessment for Studies of Diagnostic Accuracy-2, and sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (dOR), and their corresponding 95% confidence intervals (CIs) were calculated using a bivariate random-effect meta-analysis model. Meta-regression and subgroup analyses were performed to assess heterogeneity. Eighty-four study units from 18 articles with 8368 subjects were included. The pooled sensitivity and specificity of salivary DNA methylation were 0.39 and 0.87, respectively, while PLR and NLR were 3.68 and 0.63, respectively. The overall area under the curve (AUC) was 0.81 and the dOR was 8.34. The combination of methylated genes showed higher diagnostic accuracy (AUC, 0.92 and dOR, 36.97) than individual gene analysis (AUC, 0.77 and dOR, 6.02). These findings provide evidence regarding the potential clinical application of salivary DNA methylation for HNC diagnosis.


2020 ◽  
Vol 2020 ◽  
pp. 1-17
Author(s):  
Lu Wang ◽  
Mingmin Xu ◽  
Qianhua Zheng ◽  
Wei Zhang ◽  
Ying Li

Objective. The purpose of this study was to assess the effectiveness and safety of acupuncture for functional constipation (FC). Methods. A rigorous literature search was performed in English (PubMed, Web of Science, the Cochrane Library, and EMBASE) and Chinese (China National Knowledge Infrastructure (CNKI), Chinese Biological Medical (CBM), Wanfang database, and China Science and Technology Journal (VIP)) electronic databases from their inception to October 2019. Included randomized controlled trials (RCTs) compared acupuncture therapy with sham acupuncture or pharmacological therapies. The outcome measures were evaluated, including the primary outcome of complete spontaneous bowel movement (CSBM) and secondary outcomes of Bristol Stool Form Scale (BSFS), constipation symptoms scores (CSS), responder rate, the Patient Assessment of Constipation Quality of Life (PAC-QOL) questionnaire, and safety evaluation. Meta-analysis was performed by using RevMan5.3. Results. The merged data of 28 RCTs with 3525 participants indicated that acupuncture may be efficient for FC by increasing CSBMs (p<0.00001; MD = 0.84 [95% CI, 0.65 to 1.03]; I2 = 0%) and improving constipation symptoms (p=0.03; SMD = −0.4 [95% CI, −0.78 to −0.03]; I2 = 74%), stool formation (p<0.00001; MD = 0.24 [95% CI, 0.15 to 0.34]; I2 = 0%), quality of life (p<0.00001; N = 1, MD = −0.33 [95% CI, −0.45 to −0.21]), and responder rates (p=0.02; RR = 2.16; [95% CI, 1.1 to 4.24]; I2 = 69%) compared with the effects of sham treatment. No increased risk of adverse events was observed (p=0.44; RR = 1.18; [95% CI, 0.77 to 1.81]; I2 = 0%). With regard to medication comparisons, the pooled data indicated that acupuncture was more effective in increasing CSBMs (p=0.004; MD = 0.53 [95% CI, 0.17 to 0.88]; I2 = 88%) and improving patients’ quality of life (p<0.00001; SMD = −0.73 [95% CI, −1.02 to −0.44]; I2 = 64%), with high heterogeneity. However, there were no significant differences in responder rate (p=0.12; RR = 1.31; [95% CI, 0.94 to 1.82]; I2 = 53%), BSFS (p=0.5; MD = 0.17 [95% CI, −0.33 to 0.68]; I2 = 93%), or CSS (p=0.05; SMD = −0.62 [95% CI, −1.23 to −0.01]; I2 = 89%). Regarding safety evaluation, acupuncture was safer than medications (p<0.0001; RR = 0.3; [95% CI, 0.18 to 0.52]; I2 = 30%). Conclusions. Current evidence suggests that acupuncture is an efficient and safe treatment for FC. Acupuncture increased stool frequency, improved stool formation, alleviated constipation symptoms, and improved quality of life. However, the evidence quality was relatively low and the relationship between acupuncture and drugs is not clear. More high-quality trials are recommended in the future. PROSPERO registration number: CRD42019143347.


2021 ◽  
Vol 09 (06) ◽  
pp. E853-E862
Author(s):  
Samuel Han ◽  
Furqan Bhullar ◽  
Omar Alaber ◽  
Ayesha Kamal ◽  
Puanani Hopson ◽  
...  

Abstract Background and study aims Endoscopic ultrasound (EUS)-guided tissue sampling is the standard of care for diagnosing solid pancreatic lesions. While many two-way comparisons between needle types have been made in randomized controlled trials (RCTs), it is unclear which size and type of needle offers the best probability of diagnosis. We therefore performed a network meta-analysis (NMA) to compare different sized and shaped needles to rank the diagnostic performance of each needle. Methods We searched MEDLINE, EMBASE and Cochrane Library databases through August, 2020 for RCTs that compared the diagnostic accuracy of EUS fine-needle aspiration (FNA) and biopsy (FNB) needles in solid pancreatic masses. Using a random-effects NMA under the frequentist framework, RCTs were analyzed to identify the best needle type and sampling technique. Performance scores (P-scores) were used to rank the different needles based on pooled diagnostic accuracy. The NMA model was used to calculate pairwise relative risk (RR) with 95 % confidence intervals. Results Review of 2577 studies yielded 29 RCTs for quantitative synthesis, comparing 13 different needle types. All 22G FNB needles had an RR > 1 compared to the reference 22G FNA (Cook) needle. The highest P-scores were seen with the 22G Medtronic FNB needle (0.9279), followed by the 22G Olympus FNB needle (0.8962) and the 22G Boston Scientific FNB needle (0.8739). Diagnostic accuracy was not significantly different between needles with or without suction. Conclusions In comparison to FNA needles, FNB needles offer the highest diagnostic performance in sampling pancreatic masses, particularly with 22G FNB needles.


2021 ◽  
Author(s):  
Mingkai Li ◽  
Sizhe Wan ◽  
Xiaoying Wu ◽  
Bin Wu

Abstract Background/aims: To assess the performance of transient elastography (TE), two-dimensional shear wave elastography (2D-SWE), and magnetic resonance elastography (MRE) for staging significant fibrosis and cirrhosis in untreated chronic hepatitis B (CHB) patients. Methods: Pubmed, Embase, Web of Science and Cochrane Library were searched for terms involving CHB, TE, SWE, and MRE. Other etiologies of chronic liver disease (CLD), previous treatment in patients or articles not published in SCI journals were excluded. Hierarchical non-linear models were used to evaluate the diagnostic accuracy of TE, 2D-SWE and MRE. Heterogeneity was explored via analysis of threshold effect and meta-regression. Results: Twenty-eight articles with a total of 4540 untreated CHB patients were included. The summary AUROC using TE, 2D-SWE and MRE for predicting significant fibrosis (SF) were 0.84, 0.89, and 0.99, respectively. MRE is more accurate than both TE (P<0.01) and 2D-SWE (P<0.01) in staging SF. 2D-SWE is superior to TE in detecting SF (P<0.01). The summary AUROC employing TE, 2D-SWE and MRE for detecting cirrhosis were 0.9, 0.94, and 0.99, respectively. TE displayed a similar diagnostic accuracy with 2D-SWE in staging cirrhosis (P=0.14). MRE and 2D-SWE are comparable for staging cirrhosis (P=0.08). MRE is superior than TE (P<0.01) in staging cirrhosis.Conclusion: TE, 2D-SWE, and MRE express acceptable diagnostic accuracies in staging staging significant fibrosis and cirrhosis in untreated CHB patients. Both MRE and 2D-SWE are better choices while the TE can be regarded as a secondary option.


2019 ◽  
Vol 179 (1) ◽  
pp. 29-38 ◽  
Author(s):  
Hanneke E. M. van der Hoek-Snieders ◽  
Antonius J. M. L. van den Heuvel ◽  
Harmieke van Os-Medendorp ◽  
Digna M. A. Kamalski

AbstractThis systematic review aims to determine the diagnostic accuracy of fetal MRI for detecting cleft palate in fetuses at risk for orofacial clefts. Pubmed, Embase, and CINAHL were searched systematically. A diagnostic study was included if it performed MRI (index test) and postnatal examination (reference test) in fetuses at risk for orofacial clefts. Methodological quality was assessed using the QUADAS-2. A meta-analysis was performed with a random-effects model, calculating the pooled sensitivity, specificity, and area under the curve. The search resulted in eight studies (334 fetuses) to be included: four prospective and four retrospective studies. The applicability concern was low. There was, however, a risk of selection and information bias. All studies showed that MRI well predicted the chance of cleft palate. The sensitivity results were homogeneous, but heterogeneity was assumed regarding the specificity estimate (Cochrane’s Q test: p = 0.00). The pooled sensitivity was 0.97 (95% CI 0.93–0.99); the pooled specificity was 0.94 (0.89–0.97). The area under the curve was 0.98 (95% CI 0.98–0.99).Conclusion: This meta-analysis shows that MRI has an excellent sensitivity and good to excellent specificity for diagnosing cleft palate in fetuses at risk for orofacial clefts. Future research should assess applicability for clinical care.What is Known:• Using ultrasound for prenatal detection of cleft palate leads to misdiagnosis frequently.• MRI could potentially improve the prenatal detection rate of cleft palate.What is New:• Eight studies describe the diagnostic accuracy of MRI for detecting cleft palate.• Combined results show excellent sensitivity and good to excellent specificity.


BMJ Open ◽  
2019 ◽  
Vol 9 (12) ◽  
pp. e033084 ◽  
Author(s):  
Jin-Rong Ni ◽  
Pei-Jing Yan ◽  
Shi-Dong Liu ◽  
Yuan Hu ◽  
Ke-Hu Yang ◽  
...  

ObjectiveTo evaluate the diagnostic accuracy of transthoracic echocardiography (TTE) in patients with pulmonary hypertension (PH).DesignSystematic review and meta-analysis.Data sources and eligibility criteriaEmbase, Cochrane Library for clinical trials, PubMed and Web of Science were used to search studies from inception to 19 June, 2019. Studies using both TTE and right heart catheterisation (RHC) to diagnose PH were included.Main resultsA total of 27 studies involving 4386 subjects were considered as eligible for analysis. TTE had a pooled sensitivity of 85%, a pooled specificity of 74%, a pooled positive likelihood ratio of 3.2, a pooled negative likelihood ratio of 0.20, a pooled diagnostic OR of 16 and finally an area under the summary receiver operating characteristic curve of 0.88. The subgroup with the shortest time interval between TTE and RHC had the best diagnostic effect, with sensitivity, specificity and area under the curve (AUC) of 88%, 90% and 0.94, respectively. TTE had lower sensitivity (81%), specificity (61%) and AUC (0.73) in the subgroup of patients with definite lung diseases. Subgroup analysis also showed that different thresholds of TTE resulted in a different diagnostic performance in the diagnosis of PH.ConclusionTTE has a clinical value in diagnosing PH, although it cannot yet replace RHC considered as the gold standard. The accuracy of TTE may be improved by shortening the time interval between TTE and RHC and by developing an appropriate threshold. TTE may not be suitable to assess pulmonary arterial pressure in patients with pulmonary diseases.PROSPERO registration numberPROSPERO CRD42019123289.


2020 ◽  
Vol 16 (2) ◽  
pp. 83-87
Author(s):  
Bhusan Raj Timilsina ◽  
Gaurav Devkota ◽  
Shweta Giri ◽  
Sulav Pradhan ◽  
Sudeep RaJ KC

Background: Prostate cancer is one of the most common and leading cause of death among different genitourinary causes. However, screening of prostate cancer is limited to Digital Rectal Examination (DRE) and Prostate Specific Antigen (PSA) in Nepal. The aim of this study is to find out which modality is more helpful for the diagnosis of Prostate Cancer. Methods: A retrospective cross-sectional study was conducted in the department of Urology, College of Medical Sciences, Chitwan, Nepal. All patients included in this study were who presented to the OPD with Lower Urinary Tract Symptoms (LUTS). The patients were above the age of 40 with clinical suspicion prostate cancer based on either DRE or PSA.   Results: A total of 150 patients were enrolled from April 2019 to April 2020. Their mean± SD age was of 65.18±9.38 years. The accuracy of the diagnostic test for DRE and PSA were cut off at 4, PSA cut off range of 4 to 10, PSA cut off range of 10 to 30 and PSA cut off at 30 showed that all the screening indices were better for DRE (Sensitivity=100%, Specificity=59.2%, Diagnostic Accuracy=62.2%) than for PSA cut off at 4 (Sensitivity=100%, Specificity=27.6%, Diagnostic Accuracy=32.9%). Among various cut off score or ranges for PSA, cut off score at 30 provided the best screening indices with Sensitivity of 66.7%, Specificity of 97.4% and Diagnostic Accuracy of 95.1%. Conclusions: PSA has higher diagnostic accuracy then DRE. Keywords: DRE; LUTS; Prostate cancer; PSA.  


2019 ◽  
Vol 92 (1104) ◽  
pp. 20190480 ◽  
Author(s):  
Fan Zhang ◽  
Chen-Lu Liu ◽  
Qian Chen ◽  
Sheng-Chao Shao ◽  
Shuang-Qing Chen

Objective: To evaluate the diagnostic accuracy of multiparametric MRI (mpMRI) for detecting extracapsular extension (ECE) in patients with prostate cancer (PCa). Methods and materials: We searched MEDLINE, PubMed, Embase and the Cochrane library up to December 2018. We included studies that used mpMRI to differentiate ECE from organ-confined PCa with a combination of T2 weighted imaging (T2WI), diffusion-weighted imaging, and dynamic contrast-enhanced MRI. All studies included had pathological diagnosis with radical prostatectomy. Two reviewers independently assessed the methodological quality of included studies by using Quality Assessment of Diagnostic Accuracy Studies 2 tool. We calculated pooled sensitivity, specificity, positive and negative predictive values, diagnostic odds ratios and receiver operating characteristic curve for mpMRI from 2 × 2 tables. Results: A total of 17 studies that comprised 3374 participants were included. The pooled data showed a sensitivity of 0.55 (95% confidence interval 0.43, 0.66]) and specificity of 0.87 (95% confidence interval 0.82, 0.91) for extracapsular extension detection in PCa. Conclusion: First, our meta-analysis shows moderate sensitivity and high specificity for mpMRI to differentiate ECE from organ-confined prostate cancer before surgery. Second, our meta-analysis shows that mpMRI had no significant differences in performance compared with the former meta-analysis with use of T2WI alone or with additional functional MRI. Advances in knowledge: It is the first meta-analysis to evaluate the accuracy of mpMRI in combination of TWI, diffusion-weightedimaging and dynamiccontrast-enhanced-MRI for extracapsular extension detection.


2018 ◽  
Vol 17 (5) ◽  
pp. 0-10
Author(s):  
Dahai Xu ◽  
Chang Su ◽  
Liang Sun ◽  
Yuanyuan Gao ◽  
Youjun Li

Introduction and aim. Serum glypican-3 (GPC3) has been explored as a non-invasive biomarker of hepatocellular carcinoma (HCC). However, controversy remains on its diagnostic accuracy. Therefore, we aimed to conduct a systematic review and metaanalysis to evaluate the differential diagnostic accuracy of serum GPC3 between HCC and liver cirrhosis (LC) cases. Material and methods. After the strict filtering and screening of studies from NCBI, PUBMED, Clinical Trials, Cochrane library, Embase, Prospero and Web of Science databases, 11 studies were selected. All studies provided the sensitivity and specificity of GPC3 and the alpha-fetoprotein (AFP) in the HCC and LC diagnosis. The sensitivity and specificity, and the area under the receiver operating characteristic curve (AUC) were determined and compared between GPC3 and AFP, which was set as a positive control. Results. Pooled sensitivity (95% CI) and specificity (95% CI) were 0.55 (0.52-0.58) and 0.58 (0.54-0.61) for GPC3, 0.54 (0.51-0.57) and 0.83 (0.80-0.85) for AFP, and 0.85 (0.81-0.89) and 0.79 (0.73-0.84) for GPC3 + AFP, respectively. The AUCs of GPC3, AFP and GPC3 + AFP were 0.7793, 0.7867 and 0.9366, respectively. GPC3 had a nearly similar sensitivity as AFP, while the specificity and AUC of GPC3 was lower than that of AFP. The combination of GPC3 and AFP yielded a better sensitivity and AUC than GPC3 or AFP. Conclusion. Serum GPC3 is inferior to AFP in the differential diagnosis between HCC and LC. However, the combination of GPC3 and AFP exhibited a much better performance.


Sign in / Sign up

Export Citation Format

Share Document